List of products by brand Hager

Hager VE318DN Vector Distribution IP65 54 PLE QC PE/N
2-5 days
Vector distributor IP65 54 space units with QucikConnect PE and N clamp small distributor plaster; Installation small plastic distributor, according to DIN VDE 0603 part 1, according to DIN 43871. For installation of devices up to 63 A according to standard DIN 43 880 with 70 mm or 85 mm installation depth, measuring voltage AC 400 V/50 Hz. Consisting of plastic base with galvanized steel profile rail, embossing for metric line insertion sleeves (top, bottom); lateral embossings for connecting sleeves for connecting two or more distributors side by side. Built-in PE/N clamps quick connector; Top with 46 mm slot. Clear view door front flush, right or left adjustable, lockable, distributor flangeable. Installation type: Aufputz Protection class: IP65 Protection class: Protection class II Number of distribution rows: 3 Number of modules: 54Assembly type:CoatingMaterial of housing:PolystyreneType of protection:IP65Protection class:Protection class IINumber of distribution rows:3Number of modules:54Number of doors:1Type of door lock:snap closureColor:stingrayHeight installed product:602 mmWide installed product:418 mmDeep Installed Product:151 mm
€282.00
Hager ST301 Blade Transformer prim. 230VAC sec. 8/12VAC 4VA 2TE
2-5 days
Performance: 4 VAOutput voltage: 8/12 VNumber of modules: 2AC voltage: 230 VInsulation voltage: 4000 VFrequency: 50 HzTotal loss power at rated current: 1.8 WConnection cross section for flexible conductor: 4mm2Connection cross section for rigid conductor: 6mm2Operating temperature: -20 to 35 °CHeight installed product: 111 mmWide installed product: 35 mmDeep installed product: 65 mm
€25.29
Hager MLS506 cable protection switch 1P+N 6kA C-6A Quick Connect 1M
4-9 days
Rated current:6ATrigger characteristic:CNominal deactivation capacity:6Number of poles:2 PNumber of modules:1AC voltage:BY 230/240 VInsulation voltage:500 VFrequency:50/60 HzConnection type:QuickConnectTorque:1.9NmTotal power loss under rated current:1.8 WDevice life, electrical switching games:1000Machine life mechanical switching games:20000Operating temperature:-25 to 60 °CStorage temperature:-25 to 80 °CHeight installed product:86 mmWide installed product:17.5 mmDeep Installed Product:70 mm
€21.95
Hager VU36NWB Media distributor UP Underput 3-row, 1x hat rail, 2x mounting plate
2-5 days
Multimedia base, volta, UPV, 3-row, 1x hat rail, 2x mounting plate installation small distributor base made of plastic, according to OVE EN 61439-1/-3, OVE EN 60670-24 and DIN 43871, suitable for use in residential buildings according to OVE E 8015 and for installation of protective insulation VDI components. Protection class IP30, protection class II insulated. Consisting of: plastic mooring box with standard line collection and cut-out line entry slider with snap fastening, integrated water balance. Hollow wall fastening with quick fixation lever, can be mounted laterally or at the top/bottom. Rotatable frame with ventilation door made of steel sheet with ventilation slits, powder-coated and baked, with 15 mm cleaning. Ventilation door, flush with inside hand-operable hinges. Door closure with front-butting handle depression and automatically fold back handle. Door stop right or left without frame removal. Preassembled perforated mounting plates made of galvanized steel sheet with 3.2 mm hole are installed. Mounted a cover rail for direct fastening of patch panels. As an accessory, a universal retaining bracket for the screwless fastening of VDI components can be ordered and installed directly on the perforated plate, a 3-fold protective contact socket (90° rotatable). Mounting Type: Unterputz RAL Color Number: 9010 Protection Type: IP30 Height Installed Product: 630.5 mm Width Installed Product: 348 mm Depth Installed Product: 94.5 mm
€83.10
Hager ADJ966D FI/LS 16A/1+N/C/30mA G/AC
2-7 days
1P+N 6kA C-16A 30mA AC-G TypeRated current: 16 ATrigger characteristic: CNominal shutdown capacity: 6 kAType of differential protection: AC GSensitivity: 30 mANumber of poles: 2 PNumber of modules: 2AC voltage: 240 VInsulation voltage: 500 VImpact strength: 4000 VFrequency: 50 HzConnection type: screw technologyTorque: 2.1NmTotal loss power at rated current: 5.2 WDevice life, electrical switching games: 2000Machine life mechanical switching games: 2000Connection cross section for flexible conductor: 1 - 16mm2Connection cross section for rigid conductor: 1 - 25mm2Operating temperature: -5 to 40 °CStorage temperature: -25 to 70 °CHeight installed product: 83 mmWide installed product: 35 mmDeep installed product: 68 mm
€99.93
Hager ERC218 Installationsrelais 1S 1O 16A230VAC
2-5 days
Installation relays 16A 1S + 1Ö 230V Installation relays for pulse control of circuits up to max. 16 A, according to EN 61095 and DIN VDE 0637-3 as well as contact protection according to DIN VDE 0106 part 100. With contact position display by display window, integrated labeling field and suitable for subsequent installation of additional device. Notes: If several devices are installed directly, a spacer (1/2 PLE) must be installed next to each second device.Contact type: 1Ö+1SRated current: 16 A Control voltage AC current: 230 V Number of modules: 1Rated operating voltage Ue: 230 V Frequency: 50 Hz
€41.58
Hager VE412DN Vector Distribution IP65 48 PLE QC PE/N
2-5 days
small distributor, vector, APV, IP65, 48PLE, with small distribution channel; Installation small plastic distributor, according to DIN VDE 0603 part 1, according to DIN 43871. For installation of devices up to 63 A according to standard DIN 43 880 with 70 mm or 85 mm installation depth, measuring voltage AC 400 V/50 Hz. Consisting of plastic base with galvanized steel profile rail, embossing for metric line insertion sleeves (top, bottom); lateral embossings for connecting sleeves for connecting two or more distributors side by side. Built-in PE/N clamps quick connector; Top with 46 mm slot. Clear view door front flush, right or left adjustable, lockable, distributor flangeable.
Assembly type: plaster / construction Protection class: Protection class II Number of distribution rows: 4 Number of modules: 48
€235.20
Hager ACS916D FI/LS 1P+N 6kA B-Characteristic 16A 10mA Type A QC
2-5 days
1P+N 6kA B-Characteristic 16A 10mA type A QC fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 10 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V Rated current16 ATrigger characteristicBRated value6Type of differential protectionASensitivity10 mANumber2 PNumber of modules2Rated operating voltage Ue240 VInsulation voltage500 VImpact strength4,000 VFrequency50 HzTorque2.1NmDevice life, electrical switching games2000Machine life mechanical switching games2000Connection cross section with flexible conductor1 - 16mm2Connection cross section for rigid conductor1 - 25mm2Operating temperature-25 to 40 °CStorage temperature-25 to 70 °CHeight installed product94 mmWide installed product35 mmDeep Installed Product68 mm
€89.88
Hager ADS913D FI/LS 1P+N 6kA B-Characteristic 13A 30mA
2-5 days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 13 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 VRated current13 ATrigger characteristicBRated value6Type of differential protectionASensitivity30 mANumber2 PNumber of modules2Rated operating voltage Ue240 VInsulation voltage500 VImpact strength4,000 VFrequency50 HzTorque2.1NmTotal loss power at rated current3.8 WDevice life, electrical switching games2000Machine life mechanical switching games2000Connection cross section with flexible conductor1 - 16mm2Connection cross section for rigid conductor1 - 25mm2Operating temperature-25 to 40 °CStorage temperature-25 to 70 °CHeight installed product94 mmWide installed product35 mmDeep Installed Product68 mm
€89.17
Hager ADZ316D FI/LS 3X 1P+N 6kA B character. 16A 30mA Type A QC
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with 3 x 1-pole circuit breaker for 230 V AC circuits and a fault current protection circuit in the compact housing. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 16 A and at the access up to 63 A, contact protection according to IP2x DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Number of modules: 4 Rated operating voltage Ue: 230 VRated current16 ATrigger characteristicBRated value6Type of differential protectionASensitivity30 mANumber4 PNumber of modules4Rated operating voltage Ue230 VInsulation voltage500 VFrequency50 HzTorque2NmTotal loss power at rated current10.9 WDevice life, electrical switching games2000Machine life mechanical switching games2000Operating temperature-5 to 40 °CStorage temperature-55 to 70 °CHeight installed product86 mmWide installed product71 mmDeep Installed Product70 mm
€124.51