Hager ERC216 Installation relays , 16A, 2S, 230V
2-5 days
Installation relays for pulse control of circuits up to max. 16 A, according to EN 61095 and DIN VDE 0637-3 as well as contact protection according to DIN VDE 0106 part 100. With contact position display by display window, integrated labeling field and suitable for subsequent installation of additional device. Notes: If several devices are installed directly, a spacer (1/2 PLE) must be installed next to each second device.Contact type: 2S nominal current: 16 AControl voltage AC current: 230 V Number of modules: 1 Rated operating voltage Ue: 230 V Frequency: 50/60 Hz
€43.45
Hager ADG966D FI/LS 16A/1+N/C/30mA G/A fault current circuit breaker 1P+N 6kA C-16A 30mA A-G type
2-5 days
Rated current: 16 ATrigger characteristic: CNominal shutdown capacity: 6 kAType of differential protection: A GSensitivity: 30 mANumber of poles: 2 PNumber of modules: 2AC voltage: 240 VInsulation voltage: 500 VImpact strength: 4000 VFrequency: 50 HzConnection type: screw technologyTorque: 2.1NmTotal loss power at rated current: 5.2 WDevice life, electrical switching games: 2000Machine life mechanical switching games: 2000Connection cross section for flexible conductor: 1 - 16mm2Connection cross section for rigid conductor: 1 - 25mm2Operating temperature: -25 to 40 °CStorage temperature: -25 to 70 °CHeight installed product: 83 mmWide installed product: 35 mmDeep installed product: 68 mm
€78.23
Hager MBS316 LS switch 16A/3pol/B 6kA, QC QuickConnect cable protection switch 3 polig 6kA B-characteristics 16A 3 modules
2-8 days
3polig 6kA B-Characteristic 16A Quick Connect 3 Module cable protection switch with QuickConnect terminal according to DIN EN 60898-1 (VDE 0641 part 11):2003-12; EN 60898-1:2003; EN 60898-1, pr A1:2003, at the exit up to 16A and at the access for the concealment up to 63A. LS with time-delayed thermal trigger for overload protection and electromagnetic trigger for short-circuit protection. Suitable for retrofit installation of additional equipment; Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails.Rated current:16 ATrigger characteristic:BNominal deactivation capacity:6Number of poles:3 PNumber of modules:3AC voltage:OF 230/400 VInsulation voltage:500 VFrequency:50/60 HzConnection type:QuickConnectTorque:2.8 NmTotal power loss under rated current:6.3 WDevice life, electrical switching games:4000Machine life mechanical switching games:20000Operating temperature:-25 to 60 °CStorage temperature:-25 to 80 °CHeight installed product:83.4 mmWide installed product:52.5 mmDeep Installed Product:70 mm
€36.36
Hager VE112DN Vector Distribution IP65 12 PLE 12 Units with QucikConnect PE and N Terminal QC PE/N
2-5 days
Vector distributor IP65 12 space units with QucikConnect PE and N clamp small distributor plaster; Installation small plastic distributor, according to DIN VDE 0603 part 1, according to DIN 43871. For installation of devices up to 63 A according to standard DIN 43 880 with 70 mm or 85 mm installation depth, measuring voltage AC 400 V/50 Hz. Consisting of plastic base with galvanized steel profile rail, embossing for metric line insertion sleeves (top, bottom); lateral embossings for connecting sleeves for connecting two or more distributors side by side. Built-in PE/N clamps quick connector; Top with 46 mm slot. Clear view door front flush, right or left adjustable, lockable, distributor flangeable.



Assembly type:
Coating


Material of housing:
Polystyrene


Type of protection:
IP65


Protection class:
Protection class II


Number of distribution rows:
1


Number of modules:
12


Number of doors:
1


Type of door lock:
snap closure


Color:
stingray


Height installed product:
302 mm


Wide installed product:
310 mm


Deep Installed Product:
151 mm


€84.49
Hager ESC463 Insta Protector 4S 63A/230VAC Coil:230VAC
2-5 Tage
Installation protector 63A 4 Locker 230V Protector in compact design according to EN 61095 and DIN VDE 0637-3 as well as contact protection according to DIN VDE 0106 part 100. Contact position display by display window, integrated labeling field and suitable for subsequent installation of additional device. Notes: If several devices are installed directly, a spacer (1/2 PLE) must be installed next to each second device. Rated current: 63 A control voltage AC current: 230 V Number of modules: 3 Rated operating voltage Ue: 400 V Frequency: 50 Hz Connection type: Screwing technology
€94.44