List of products by brand Hager

Hager ADZ366D FI/LS 3X 1P+N 6kA C character. 16A 30mA Type A QC
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with 3 x 1-pole circuit breaker for 230 V AC circuits and a fault current protection circuit in the compact housing. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 16 A and at the access up to 63 A, contact protection according to IP2x DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: C Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Number of modules: 4 Rated operating voltage Ue: 230 VRated current16 ATrigger characteristicCRated value6Type of differential protectionASensitivity30 mANumber4 PNumber of modules4Rated operating voltage Ue230 VInsulation voltage500 VFrequency50 HzTorque2NmTotal loss power at rated current10.9 WDevice life, electrical switching games2000Machine life mechanical switching games2000Operating temperature-5 to 40 °CStorage temperature-55 to 70 °CHeight installed product86 mmWide installed product71 mmDeep Installed Product70 mm
€130.72
Hager ACS916D FI/LS 1P+N 6kA B-Characteristic 16A 10mA Type A QC
2-5 days
1P+N 6kA B-Characteristic 16A 10mA type A QC fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 10 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V



Rated current
16 A


Trigger characteristic
B


Rated value
6


Type of differential protection
A


Sensitivity
10 mA


Number
2 P


Number of modules
2


Rated operating voltage Ue
240 V


Insulation voltage
500 V


Impact strength
4,000 V


Frequency
50 Hz


Torque
2.1Nm


Device life, electrical switching games
2000


Machine life mechanical switching games
2000


Connection cross section with flexible conductor
1 - 16mm2


Connection cross section for rigid conductor
1 - 25mm2


Operating temperature
-25 to 40 °C


Storage temperature
-25 to 70 °C


Height installed product
94 mm


Wide installed product
35 mm


Deep Installed Product
68 mm


€66.00
Hager ADS913D FI/LS 1P+N 6kA B-Characteristic 13A 30mA
2-5 days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 13 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V



Rated current
13 A


Trigger characteristic
B


Rated value
6


Type of differential protection
A


Sensitivity
30 mA


Number
2 P


Number of modules
2


Rated operating voltage Ue
240 V


Insulation voltage
500 V


Impact strength
4,000 V


Frequency
50 Hz


Torque
2.1Nm


Total loss power at rated current
3.8 W


Device life, electrical switching games
2000


Machine life mechanical switching games
2000


Connection cross section with flexible conductor
1 - 16mm2


Connection cross section for rigid conductor
1 - 25mm2


Operating temperature
-25 to 40 °C


Storage temperature
-25 to 70 °C


Height installed product
94 mm


Wide installed product
35 mm


Deep Installed Product
68 mm


€73.20
Hager ADS916D FI/LS 1P+N 6kA B-Characteristic 16A 30mA
3-8 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V



Rated current
16 A


Trigger characteristic
B


Rated value
6


Type of differential protection
A


Sensitivity
30 mA


Number
2 P


Number of modules
2


Rated operating voltage Ue
240 V


Insulation voltage
500 V


Impact strength
4,000 V


Frequency
50 Hz


Torque
2.1Nm


Total loss power at rated current
5.2 W


Device life, electrical switching games
2000


Machine life mechanical switching games
2000


Connection cross section with flexible conductor
1 - 16mm2


Connection cross section for rigid conductor
1 - 25mm2


Operating temperature
-25 to 40 °C


Storage temperature
-25 to 70 °C


Height installed product
94 mm


Wide installed product
35 mm


Deep Installed Product
68 mm


€48.96
Hager SU212 Bladel 8-12V/0,33A, 1 PLE
2-5 days
Blade 8-12V 5VA 1PLEBlade transformer with protection against short circuit or overload by an integrated thermal switch on the primary side. Number of modules: 1 Operating voltage AC: 8/12 V Frequency: 50/60 Hz
€25.45
Hager MCS320 LS switch 3P 6kA C-20A QC circuit breaker 3 polig 6kA C-characteristics 20A QuickConnect 3 modules
2-8 days
3polig 6kA C-Characteristic 20A QuickConnect 3 Module cable protection switch with QuickConnect terminal according to DIN EN 60898-1 (VDE 0641 part 11):2003-12; EN 60898-1:2003; EN 60898-1, pr A1:2003, at the exit up to 16A and at the access for the concealment up to 63A. LS with time-delayed thermal trigger for overload protection and electromagnetic trigger for short-circuit protection. Suitable for retrofit installation of additional equipment; Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails.Rated current:20 ATrigger characteristic:CNominal deactivation capacity:6Number of poles:3 PNumber of modules:3AC voltage:OF 230/400 VInsulation voltage:500 VFrequency:50/60 HzConnection type:QuickConnectTorque:2.8 NmTotal power loss under rated current:8.9 WDevice life, electrical switching games:4000Machine life mechanical switching games:20000Operating temperature:-25 to 60 °CStorage temperature:-25 to 80 °CHeight installed product:83.4 mmWide installed product:52.5 mmDeep Installed Product:70 mm
€56.83
Hager VU12AT small distributor UP, Volta, 1x12(+2)TE, IP30, B335xH340xT90mm niche dimension
2-5 days
Mounting type: UnderputMaterial of housing: plasticProtection type: IP30Protection class: Protection class IINumber of distribution rows: 1Number of modules: 12Number of doors: 1Door closure type: snap closureRAL colour number: 9010Color: whiteHeight installed product: 356 mmWide installed product: 348 mmDeep installed product: 94,5 mm
€52.00
Hager VE118DN Vector Distribution IP65 18 PLE QC PE/N
2-5 days
small distributor, vector, APV, IP65, 18PLE, with small distribution channel; Installation small plastic distributor, according to DIN VDE 0603 part 1, according to DIN 43871. For installation of devices up to 63 A according to standard DIN 43 880 with 70 mm or 85 mm installation depth, measuring voltage AC 400 V/50 Hz. Consisting of plastic base with galvanized steel profile rail, embossing for metric line insertion sleeves (top, bottom); lateral embossings for connecting sleeves for connecting two or more distributors side by side. Built-in PE/N clamps quick connector; Top with 46 mm slot. Clear view door front flush, right or left adjustable, lockable, distributor flangeable.
Assembly type: plaster / construction Protection class: Protection class II Number of distribution rows: 1 Number of modules: 18
€130.83
Hager EVN002 Remote dimmer 500W universal LED/ESL
2-5 days
Remote dimmer 500W Universal, LED/ESL remote dimmer for controlling dimmable energy saving and LED lamps, bulbs, 230V halogen lamps and NV halogen lamps with coiled or electronic Trafo. Automatic load detection Detection method and learning function via external Taster. Memory function is used when switching on Activation of the last set value. With low space requirement and low standby consumption of 0,2W. Remote control of the dimmer by probe also illuminated possible. Electronic short circuit and over- Temperature protection. Frequency: 50/60 Hz Performance: 500 VA Performance of conventional transformer 230 V: 500 VA Power transformer/EVG 230 V: 500 VA Operating temperature: -20 to 50 °C Storage temperature: -20 to 50 °C Number of modules: 2 Protection type: IP20 Assembly type: DIN rail (REG) Load type: universal