Eltako

Eltako MFZ12DDX-UC MULTIFUNCTION RELAIS
Eltako MFZ12DDX-UC MULTIFUNCTION RELAIS
3-10 days
multifunction time relays for mounting on support rail DIN-EN 50 022, digitally adjustable universal voltage multifunction time relays MFZ12DDX-8.230 V UC, 10A/250V AC, universal control voltage 8..230V UC, supply voltage such as the control voltage, with Eltako-Duplex technology TLE: 1 number of contacts as changer: 1 voltage type for actuation: AC Digital adjustable multifunction time relay with 18 functions. Stand-by loss only 0.05 - 0.5 Watt. To this end, simply connect the N conductor to the terminal (N) and L to 15 (L). This results in an additional stand-by consumption of only 0.1 Watt. Universal control voltage 8..230V UC. Supply voltage like the control voltage. Both the function and the times are entered with keystroke and displayed digitally on an LC display. Only two buttons are to be used. In the time setting, all values can be entered within the preselected time frame (0.1-9.9 or 1-99 seconds, minutes or hours). The longest time is 99 hours. 600 time settings are possible. The entered time(s) is constantly displayed digitally. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network.
€60.22
Eltako MTR12-8..230V UC engine separation relay
Eltako MTR12-8..230V UC engine separation relay
3-10 days
Power surge group switches for central control Processor controlled, EGS12Z2 and EGS12Z convert the commands of the sensors or the downstream sensor relays and switch two motors or one motor or the motor disconnect relay MTR12. control voltage at terminals +B1 --A2 or. A3 to A8 shall be the same potential, the following non-sections: automatic transmission, reverse deceleration, automatic transmission, duration up to Aba3 and A4 for local control with a normal double shutter switchA3 and A4 alternating shutter for static central control a5 and A6 for local control with a normal double shutter measurement A5 and A6 alternating shutter. Stand-by loss only 0.5 Watt. 1 division unit. The tube motors of shading elements and roller shutters must not be directly connected in parallel, since otherwise, over the limit switches, back tensions and finally the destruction of the motors occur. For a motor and if the control voltage and the motor voltage are 230W, however, an EGS12Z-UC is sufficient to control more than one motor with an EGS12Z-UC or if the control voltage is unequal, a MTR12-UC must be connected for each two motors. The MTR12-UC can be operated in parallel, but require free contact outputs K2/K3 of the controlling EGS12Z-UC. These are connected to the terminals K2/K3 of the MTR12-UC. 1/2 = motor 1, 3/4 = motor 2. With a rotary switch, the functions can be locked on or off and can be switched off completely. This lock applies only to the max. 2 connected motors. In this way, individual shading elements or roller shutters can be completely or partially excluded from the automatic function of an overall controller
€61.86
Eltako WNT12-24VDC-12W/0.5A power supply
Eltako WNT12-24VDC-12W/0.5A power supply
3-10 days
Wide-range switching power supply for mounting on support rail DIN-EN 60715 TH35 overload and overtemperature protection by disconnecting with automatic switch-on after the fault removal (autorecovery function) wide-range switching power supply. Stand-by-loss only 0.2 Watt. With a load greater than 50% of the rated power and always with adjacent switching power supply components greater than 12 watts of rated power, and with dimmers, a 1/2 division unit is required on both sides with the distance pieces DS12. Efficiency 86%. Stabilized output voltage ±1%, low residual ripple. Short circuit. Overload and overtemperature protection by switching off with automatic switching on after eliminating errors (autorecovery function). Secondary voltage 1: 24 W Width: 18 mm Max. Output power: 12 W Max. Output current: 0.5 A width in division units: 1
€62.41
Eltako SNT12-230V/24VDC-1A power supply
Eltako SNT12-230V/24VDC-1A power supply
3-10 days
Switching power supplies for mounting on support rail DIN-EN 60715 TH3Stand-by-loss 0.2 Watt, short-circuit-proof, with a load greater than 50% of the rated power and always with adjacent switching power supplies above 12 Watt rated power and with dimmers a 1/2 division of ventilation unit with spacers DS12 is required, input voltage 230W AC, -(20% to +10)%, efficiency 12W DC 83%, 24W DC. With a load greater than 50% of the rated power and always with adjacent switching power supply components greater than 12 watts of rated power, and with dimmers, a 1/2 division unit is required on both sides with the distance pieces DS12. Efficiency 24W DC 87%. Stabilized output voltage ±1%, low residual ripple. Short circuit. Overload and overtemperature protection by switching off with automatic switching on after eliminating errors (autorecovery function).
€62.41
Eltako WNT12-12VDC-12W1A Wide-switched.
Eltako WNT12-12VDC-12W1A Wide-switched.
3-10 days
Wide-range switching power supply for mounting on support rail DIN-EN 60715 TH35 overload and overtemperature protection by disconnecting with automatic switch-on after the fault removal (autorecovery function) wide-range switching power supply. Stand-by-loss only 0.2 Watt. With a load greater than 50% of the rated power and always with adjacent switching power supply components greater than 12 watts of rated power, and with dimmers, a 1/2 division unit is required on both sides with the distance pieces DS12. Efficiency 83%. Stabilized output voltage ±1%, low residual ripple. Short circuit. Overload and overtemperature protection by switching off with automatic switching on after eliminating errors (autorecovery function). Secondary voltage 1: 12 W Width: 18 mm Max. Output power: 12 W Max. Output current: 1.0 A width in division units: 1
€62.41
Eltako SNT14-24V/24W Switching Power Supply 24V DC/24W
Eltako SNT14-24V/24W Switching Power Supply 24V DC/24W
3-10 days
Short circuit: Yes 1st output voltage: 24 - 24 W voltage type of supply voltage: DC Max. Output current 1: 1 A output voltage adjustable: No Rated supply voltage at AC 50 Hz: 230 - 230 W Stabilized: Yes Electrical connection design: Screw connection output voltage regulated: Yes Power consumption: 0.2 VA Power output: 24 W Suitable for series installation: Yes Support rail mounting possible: Yes Wall mounting possible: No Protection type (IP): IP20 Height: 58 mm Width: 36 mm Depth: 58 mm Power supply for 24V. Rated power 24W. Stand-by loss only 0.2 Watt. DIN-EN 60715 TH35 for mounting on support rail. 2 division units = 36mm wide, 58mm deep. With a load greater than 50% of the rated power and always with adjacent switching power supply components greater than 12 watts of rated power, and with dimmers, a 1/2 division unit is required on both sides with the distance pieces DS12. Input voltage 230W -(20% to +10) % efficiency 87%. Stabilized output voltage ±1%, low residual ripple. Short circuit. Overload and overtemperature protection by switching off with automatic switching on after eliminating errors (autorecovery function). The 24W DC output of these switched-mode power supplies is at the bottom so that a fast connection to the FAE14LPR actuators for 24W DC actuators can be established with the busbars SAS-. The SNT14 is always mounted to the right next to the last actuator FAE14LPR, since no plug-in bridge is provided. Power supply for 24V actuators. Stand-by loss only 0.2 Watt. With a load greater than 50% of the rated power and always with adjacent switching power supply components greater than 12 watts of rated power, and with dimmers, a 1/2 division unit is required on both sides with the distance pieces DS12. Efficiency 86%. Stabilized output voltage ±1%, low residual ripple. Short circuit. Overload and overtemperature protection by automatic shutdown
€62.41
Eltako ESR12DDX-UC Electronic power surge.
Eltako ESR12DDX-UC Electronic power surge.
3-10 days
multifunction power surge relay for mounting on support rail DIN-EN 60715 TH35 1+1 closer, it can be selected between 18 different power surge switches or relay functions with which Eltako-Duplex technology (DX) can switch the potential-free contacts when switching 230V AC / 50Hz in the zero crossing of the sine wave, supply and control voltage 8..230V UC, rated switching power 16A/250V AC TLE: 1 number of locks: 2 number of openers: 2 width in division units: 1 Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Fluorescent lamp load (Duo circuit): 1000 VA Max. Incandescent lamp load: 2000 W supply voltage range: 8 - 230 V control voltage 1: 8 - 230 V control voltage type 1: AC/DC frequency of control voltage 1: 50 - 50 Hz Max. Lamp load: 1000 VA Max. Switching current (cos phi = 0.6): 4 A Installation depth: 58 mm Function: partially electronic digital adjustable multi-function current surge relays. Stand-by loss only 0.03 to 0.4 Watt. To this end, simply connect the N conductor to the terminal (N) and L to 1(L) and/or 3(L). This results in an additional stand-by loss of only 0.1 Watt. Universal control voltage 8..230V UC. Supply voltage like the control voltage. The functions are entered according to the user manual with the MODE and SET keys and displayed digitally on an LC display, optionally also locked. The run-on time is constantly displayed. Due to the use of bistable relays, there is no coil loss power and no heating thereby even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Only for the power surge switch functions: If the supply voltage fails, it is switched off in a defined manner depending on the setting or the switching position is maintained (then + in the display next to the function shortening).
€64.05
Eltako EGS12Z-8..230VUC Electric shock group shell.
Eltako EGS12Z-8..230VUC Electric shock group shell.
3-10 days
Power surge group switches for central control Processor controlled, EGS12Z2 and EGS12Z convert the commands of the sensors or the downstream sensor relays and switch two motors or one motor or the motor disconnect relay MTR12. control voltage at terminals +B1 --A2 or. A3 to A8 must be the same potential, the following non-sections: automatic transmission, reverse deceleration, automatic transmission, duration up, duration Aba3 and A4 for local control with a normal double shutter switchA3 and A4 alternating controller for the static central controller A5 and A6 for local control with a normal double shutter A5 and A6 alternating actuator A7 dynamic for the central controller A250. Electric shock group switches for central control for 1 motor or for motor relays. Stand-by loss only 0.05 to 0.4 Watt. This current surge group switch converts the commands of the sensor relays or of switches and pushbuttons, and switches a motor, motor separation relays MTR12-UC or DC motor relays depending on the setting of the turntables on the front side. The operating principle of this current surge group switch is that, on the one hand, on the other hand, on the other hand, on the other hand, both contacts can be controlled in a pulse-wise manner, on the other hand, on the other hand, by means of additional control inputs can be selected specifically on or off. Dynamically denotes control inputs in which a pulse of at least 20 ms is sufficient to close a contact. Static is a control input in which the contact is closed only as long as the control command is present. The names on and off apply to roller shutters, blinds and roller blinds. Number of locks: 2 Width in division units: 2 Rated switching current: 16 A Control voltage 1: 8 - 230 W
€64.05
Eltako LUD12-230V Power additive
Eltako LUD12-230V Power additive
3-10 days
Universal dimming switch for mounting on support rail DIN-EN 60715 TH35 Power MOSFET up to 400 W, for lamps up to 400 W, depending on the ventilation conditions, dimmable energy-saving lamps ESL and dimmable 230 V-LED lamps additionally depending on the lamp electronics, automatic lamp detection, minimum or maximum brightness and dimming speed adjustable, children's room and slumber circuit. Power MOSFET up to 400W. Stand-by loss only 0.1 Watt. The load type of a power additive can differ in the circuit power increase with additional lights from the load type of the universal dimming switch. This makes it possible to mix L-Lasten and C-Lasten. This setting must match the actual installation, otherwise the electronics could be destroyed! Width in division units: 1 Number of outputs: 1 Output power from/to: 400 - W Voltage range: 230 - W Power supply usable: Yes Bus system EIB/KNX: No Bus system Radio bus: No Bus system Powernet: No Bus connection included: No Bus system LON: No Other bus systems: without on-site/hand operation: Yes With LED display: Yes Parallel operation possible: No
€64.59
Eltako NR12-002-3X230V NEWS
Eltako NR12-002-3X230V NEWS
3-10 days
Power monitoring relay for mounting on support rail DIN-EN 60715 TH35, for monitoring 230 W AC voltage against the zero conductor, drop delay adjustable 0.1 to 8 seconds, draw delay 0.5 s, LED display for applied voltage, with the lower rotary switch on the front side two draw-on or respectively. Relapse voltages are set: U1: 161W drop-back voltage and 185V draw voltage U2: 196W drop-back voltage and 206W draw-on voltage according to. WDE 0100 part 718 network monitoring relay with field monitoring. Stand-by loss only 0.8 Watt. Mounting unit for mounting on support rail (2 TE). For monitoring 230W AC voltage between 1 to 3 external conductors and the neutral conductor and for monitoring the rotary field (rotating in the right) in the rotary switch positions 2ph and 3ph. In the position L1/L2/L3, only the rotary field is monitored, regardless of the mains voltage. If L1 fails, the relay will drop immediately without a relapse delay. With the lower rotary switch on the front side, two draw or. Relapse voltages are set and the number of monitored external conductors must be specified. U1: 161W falling voltage and 185V tightening voltage. U2: 196W falling voltage and 206W tightening voltage according to. WDE 0100, Part 718 (formerly: WDE 0108, Part 1). LED display for correct applied voltage. In case of incorrect polarity or a missing external conductor, the LED flashes quickly. Relapse delay RV with the upper rotary switch adjustable from 0.1 to 8 seconds. While the RV time is running, the LED flashes slowly. Suit delay 0.5s. Number of contacts as changer: 2 TLE: 2
€65.14
Eltako WNT12-12VDC-24W/2A power supply
Eltako WNT12-12VDC-24W/2A power supply
3-10 days
Wide-range switching power supply for mounting on support rail DIN-EN 60715 TH35 overload and overtemperature protection by disconnecting with automatic switch-on after the fault removal (autorecovery function) wide-range switching power supply. Stand-by-loss only 0.2 Watt. With a load greater than 50% of the rated power and always with adjacent switching power supply components greater than 12 watts of rated power, and with dimmers, a 1/2 division unit is required on both sides with the distance pieces DS12. Efficiency 83%. Stabilized output voltage ±1%, low residual ripple. Short circuit. Overload and overtemperature protection by switching off with automatic switching on after eliminating errors (autorecovery function). Secondary voltage 1: 12 W Width: 36 mm Max. Output power: 24 W Max. Output current: 2.0 A width in division units: 2
€68.96
Eltako WNT12-24VDC-24W/1A power supply
Eltako WNT12-24VDC-24W/1A power supply
3-10 days
Wide-range switching power supply for mounting on support rail DIN-EN 60715 TH35 Overload and overtemperature protection by switching off with automatic switching on after the fault elimination (autorecovery function) secondary voltage 1: 24 W Width: 36 mm Max. Output power: 24 W Max. Output current: 1.0 A width in division units: 2 wide range switching power supply. Stand-by-loss only 0.2 Watt. With a load greater than 50% of the rated power and always with adjacent switching power supply components greater than 12 watts of rated power, and with dimmers, a 1/2 division unit is required on both sides with the distance pieces DS12. Efficiency 87%. Stabilized output voltage ±1%, low residual ripple. Short circuit. Overload and overtemperature protection by switching off with automatic switching on after eliminating errors (autorecovery function).
€68.96
Eltako FR61-230V
Eltako FR61-230V
3-10 days
Field-free switches for UP assembly Self-learning field-free switches, non-potential-free 10A/250V AC, stand-by-loss only 0.8 Watt, supply and switching voltage 230W interrupts the power supply after disconnection of downstream consumers and thus prevents interfering electromagnetic fields. Self-learning processor for the current thresholds Self-learning field switch 230W. 1 lock not potential-free 10A/250V AC. Stand-by-loss only 0.8 Watt. For installation. 45mm long, 45mm wide, 26mm deep. Supply and switching voltage 230W. Modern hybrid technology combines the advantages of wear-free electronic control with high switching power from special relays. The field-free switch FR61-230V interrupts the power supply after disconnection of downstream consumers and thus prevents interfering electromagnetic fields. Up to a current consumption of 20ma, small consumers are allowed, which do not prevent field-free switching after larger consumers are switched off. The limit value does not have to be set manually, but is learned by the FR61. Consumers with more than 200ma current consumption are always defined as consumers which are intended to cause the power supply to be switched on. As long as no larger consumer is switched on, the monitored circuit 1-pole remains switched off from the network. Neutral and protective conductors are not switched to prevent an antenna effect. A DC voltage 230W DC with low residual ripple is present for monitoring. Therefore, a bridging of the working contact is not permissible and leads to destruction of the device. When a consumer is switched on, the field-free switch switches the monitored outer conductor. When the outer conductors are switched on first and after a power failure, the FR61 automatically learns new: first, a switch-on current of 30ma is predetermined. If then a small consumer is switched on for more than 24 hours, the total current consumption d
€69.95
Eltako FSR14-4x RS485-Bus actuator 4-channel
Eltako FSR14-4x RS485-Bus actuator 4-channel
3-10 days
Current surge relays for mounting on support rail DIN-EN 60715 TH35, 16 A/250 V AC, potential-separated from supply voltage, with DX technology, bidirectional, stand-by-loss only 0.1 Watt current surge relays with 4 channels, each 1 closer 4A/250V AC, -Glüh lamps 1000W, potential-separated from supply voltage, with DX. Bidirectional. Stand-by loss only 0.1 Watt. Connection to Eltako-RS485-Bus. Cross-wiring bus and power supply with plug-in bridge. To this end, simply connect the N conductor to the terminal (N) and L to K(L). This results in an additional stand-by loss of only 0.1 Watt. If all 4 relays of the FSR14-4x are switched on, 0.7 watts are required. If the supply voltage fails, it is switched off in a defined manner. The channels can be taught independently as ES and/or ER channels. Scene control: A plurality of channels of one or more FSR14-4x can be switched on or off to one scene with one of the four control signals of a pushbutton learned as a scene scanner. Central commands on the PC are sent with the building radio visualization and control software GFVS. Learn one or more FSR14-4x on PC. With the rotary switches, the probes are learned and the 4 channels are tested if necessary. The LED under the upper rotary switch accompanies the learning process according to the user manual and displays control commands during operation by short flashing. Width in division units: 1 Max. Switching current: 4 A Max. Switching power: 1000 W Max. Number of switching outputs: 4 Bus system EIB/KNX: No Bus system Funkbus: Yes Bus system Powernet: No Bus connection included: Yes Bus system LON: No On site/hand operation: Yes With LED indicator: No Different phases connectable: No Modular expansion option: No
€70.05
Eltako FSR14-2x RS485-Bus actuator 2-channel
Eltako FSR14-2x RS485-Bus actuator 2-channel
3-10 days
Electric shock switch relays for mounting on support rail DIN-EN 60715 TH35, 16 A/250 V AC, potential-separated from supply voltage, with DX technology, bidirectional, stand-by-loss only 0.1 Watt power surge switch relays with 2 channels, 1+1 lock potential-free 16A/250V AC, light bulbs 2000W, with DX technology. Bidirectional. Stand-by loss only 0.1 Watt. Row mounting device for mounting on support rail. Connection to Eltako-RS485-Bus. Cross-wiring bus and power supply with plug-in bridge. To this end, simply connect the N conductor to the terminal (N1) and L to 1(L) and/or N to (N2) and L to 3(L). This results in an additional stand-by loss of only 0.1 Watt. If the supply voltage fails, the switching state is maintained. When the supply voltage is recurring, it is switched off in a defined manner. The channels can be taught independently as ES and/or ER channels. Scene control: A plurality of channels of one or more FSR14-2x to one scene can be switched on or off with one of the four control signals of a pushbutton learned as a scene scanner. Central commands on the PC are sent with the building radio visualization and control software GFVS. The LED under the upper rotary switch accompanies the learning process according to the user manual and displays control commands during operation by short flashing. Max. switching current: 16 A Max. Switching power: 2000 W Width in division units: 1 Max. Number of switching outputs: 2 Bus system EIB/KNX: No Bus system Funkbus: Yes Bus system Powernet: No Bus connection included: Yes Bus system LON: No On site/hand operation: Yes With LED indicator: No Different phases connectable: No Modular expansion option: No
€72.14