List of products by brand Eltako

Eltako DSZ15D3x80A MID three-phase counter MID gee
3-10 days
Electrical power meter Maximum power 3x80A, Stand-by-loss only 0.5 Watt per path, Row-mounting device for mounting on support rail DIN-EN 60715 TH35 in installation cabinets with protection class IP51, 4 division units = 70 mm wide, 58 mm deep, accuracy class B (1)%, with S0 interface, which measures directly measuring rotary power meter
€189.93
Eltako S09-230VAC power surge switch
3-10 days
Switching devices for DIN EN 50022, rated switching power 16 A/250 W AC or 10 A/400 W AC. Current surge switches mechanical storage of the switching position Current surge switches with manual actuation and switching position display. Only 1/2 division unit. 5W. For pulse control. Contact distance 3mm. Width in division units: 0.5 Number of changers: 0 Number of switches: 1 Number of openers: 0 Rated switching current: 16 A Control voltage 1: 230 - 230 W Control voltage type 1: AC Installation depth: 55 mm Function: other assembly type: DIN rail Frequency of control voltage 1: 50 - 50 Hz Voltage type of supply voltage: AC Supply voltage range: 250 - 250 W Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 8 A manual operation possible: Yes
€26.67
Eltako R12-110-230V AC INHALATION RELAY
3-10 days
Switching relay for mounting on support rails DIN-EN 60715 TH35 rated switching power 16 A/250 W AC or. 10 A/400 W AC Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W. Number of contacts as locks: 1 Voltage type for actuation: AC Number of contacts as openers: 1 TLE: 1 Rated control voltage Us at AC 50 Hz: 230 - W
€27.26
Eltako P3K12-230V PHASENKONTROL
3-10 days
Design of the electrical connection screw connection, measurement control supply voltage Us at AC 50 Hz 230 ... 400V, measurement control supply voltage Us at AC 60 Hz 230 ... 400V, voltage type for actuation AC, function phase failure detection, width 17.5mm, for optical monitoring of 1 to 3 phases 230 V. Display by three red light-emitting diodes for 230 V AC. Number of contacts as locks: 0 Number of contacts as openers: 0 Type of electrical connection: Screw connection Type of voltage for actuation: AC Number of contacts as changer: 0 Width: 18 mm Height: 58 mm Depth: 58 mm Function Overvoltage detection: No Rated control voltage Us at AC 50 Hz: 230 - 230 V With removable clamps: No Function Phase sequence detection: No Function. Series installation unit with 1 division unit. For optical monitoring of 1 to 3 external conductors 230V. Display with three red light-emitting diodes.
€44.26
Eltako ER12 DX-UC Universalsp. Relay
3-10 days
Switching relay for mounting on support rails DIN-EN60715 TH35 No heat losses due to internal bistable relay,DX=Eltako-Duplex technology, switch in the zero crossing of the sine wave of a 230V switching voltage, low switching noise, control indicator with light-emitting diode, integrated freewheel/lowering diode (A1 =+, A2 =−) switching relays. No standby loss. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. To this end, simply connect the N conductor to the terminal (N) and L to 1 (L). This results in a stand-by consumption of only 0.1 Watt. If the contact is used for controlling switching devices which themselves do not switch in the zero passage, (N) should not be connected, since the additional closing delay otherwise causes the opposite. Very low switching noise. Control indicator with light-emitting diode. The connection terminal occupancy is identical to the electromechanical switching relay R12-100-. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. The relay contact can be open or closed during commissioning and synchronizes during the first actuation. This relay is not suitable for feedback with the switching voltage of a dimming switch. The electronics have no own power supply and therefore no stand-by loss. Only when the control contact is closed is the microcontroller which switches the bistable relay in the correct direction. When the control contact is opened or a falling control voltage is switched back. TLE: 1 Number of contacts as closer: 1 Rated control voltage Us at AC 50 Hz: 8 - 230 V
€44.96
Eltako TLZ61NP-8..230VUC Stair switch. UP
3-10 days
Steplight time switch, electronic for UP mounting, built-in device quietly and timely, max. 50ma Glow lamp current, time range stepless to 10 minutes adjustable, 4-wire switchable, rated switching power 10 A/250 W AC, control voltage 8...230 W UC Stair switch 230V+UC. 1 lock not potential-free 10A/250V AC, incandescent lamps up to 2000W, ESL and LED lamps up to 200W, switch-off warning and push-button continuous light. Stand-by-loss only 0.7 Watt. With ESL optimization. For installation. 45mm long, 45mm wide, 18mm deep. Contact circuit in the zero passage for protecting the contacts and lamps. In particular, this extends the service life of energy-saving lamps. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Control, supply and switching voltage 230W. In addition with galvanically separated universal control voltage 8..230V UC. Time setting 1 to 12 minutes. Glow lamp current up to 50ma, depending on the ignition voltage of the glow lamps. For 3- and 4-wire circuits, switchable, with attic lighting at 4-wire circuit. Automatic detection of the circuit type. After a power failure, the illumination is switched on again when the time sequence has not yet been completed. When switched off, the lighting flickers approx. 30 seconds before the time sequence beginning and a total of 3 times in shorter time intervals. When the pushbutton permanent light is switched on, it is possible to set for longer than 1 second by means of buttons, which is switched off automatically after 60 minutes or can be switched off with buttons for longer than 2 seconds. If the pushbutton continuous light and the switch-off pre-warning are switched on, the switch-off pre-warning takes place after the switch-off of the continuous light. All or part of
€47.91
Eltako ES12-200-UC 8..230V UC power surge switch
3-10 days
Power surge switch, electronic for mounting on support rail DIN-EN 60715 TH35 potential-free 16A/250V AC, incandescent lamps 200W No stand-by loss, maximum current as the sum of both contacts 20A at 230V, connection terminal occupancy is identical with current surge switch S12 width in division units: 1 Number of switches: 2 Rated switch current: 16 A. Bulb load: 2000 W Max. Lamp load: 1000 VA Max. Fluorescent lamp load (Duo circuit): 1000 VA Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 4 A manual operation possible: No power surge switch UC. No standby loss. Either universal control voltage 8..230V UC at the control input +A1/-A2 or 230W with up to 5ma glow lamp current at the control input with glow lamp symbol (L)/-A2(N). The simultaneous use of two potentials at the tax inputs is not permissible. Very low switching noise. No constant power supply required, therefore no stand-by loss. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. The relay contact can be open or closed during commissioning and synchronizes during the first actuation. Maximum current as a sum of both contacts 16A at 230W.
€48.51
Eltako RVZ12DX-UC time relay
3-10 days
Multifunction time relays for mounting on support rail DIN-EN 60715 TH35, for all control voltages from 8 to 230W DC and AC (50/60 Hz), times between 0.1 seconds and 40 hours with the time bases 0.1, 0.5, 2 and 5 seconds, 1, 2 and 5 minutes, 1, 2 and 4 hours as well as the multiplier of 1-10 are adjustable, contact circuit in the zero crossing of the sinus wave, 0.1 Watt-by-adjustable time. Stand-by-loss only 0.02 - 0.4 Watt. This analog adjustable time relay is identical to the multifunction time relay, but has only one function. To this end, simply connect the N conductor to the terminal (N) and L to 15 (L). This results in an additional stand-by consumption of only 0.1 Watt. Universal control voltage 8..230V UC. Supply voltage like the control voltage. Time range from 0.1 seconds to 40 hours. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. The light-emitting diode under the large rotary switch informs about the contact position during the time sequence. control voltage 1: 8 - 230 W control voltage type 1: AC/DC switching power fluorescent lamps parallel: 500 VA 1. Time range from/to: 40 - 0.1 Function: Relapse delay Number of switches: 1 Switching power Incandescent lamps: 2000 W Width in division units: 1 Supply voltage range: 8 - 230 W Switching power Fluorescent lamps inductor: 1000 VA Mounting height: 58 mm Switching power Fluorescent lamps DUO: 1000 VA. Time unit: minutes/hour assembly type: DIN rail
€56.77
Eltako ES12Z-200-8..230V UC power breaker
3-10 days
Current surge switches, electronic for central control work contacts and control inputs are central/local are galvanically separated, therefore local can be controlled with another phase and voltage, as central, with rotary switches various priorities can be set between the different control inputs, in this case it is also decided whether the device switches off in a defined manner after a mains failure or maintains the switch position, Glimm lamp current equal to 110W control voltage. Stand-by loss only 0.03 to 0.4 Watt. Priorities of central control can be selected. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. With additional control inputs centrally and centrally separated from the local control input for 8.230V UC. Supply voltage like the local control voltage. Very low switching noise. Glow lamp current from 110W control voltage up to 50ma in switch positions 1 to 3 and 5 to 7. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Maximum current as a sum of both contacts 16A at 230W. With control LED. This flashes after 15 seconds with blocked local probe, not in the rotary switch positions 4 and 8. With the upper rotary switch, this current surge switch can be completely or partially excluded from the central control. Width in division units: 1 Number of locks: 2 Rated switching current: 16 A Installation depth: 58 mm Function: electronic switch Assembly type: DIN rail Frequency of control voltage 1: 50 - 50 Hz Fre
€60.32
Eltako AR12DX-230V power relay
3-10 days
Current relays for mounting on support rail DIN-EN 60715 TH35, potential-free 16 A /250 W AC, stand-by loss only 0.8 Watt current relay, stand-by loss only 0.8 Watt. Mounting unit for mounting on support rail (1 TE). To this end, simply connect the N conductor to the terminal (N) and L to 1 (L). This results in an additional stand-by consumption of only 0.1 Watt. If the contact is used for controlling switching devices which themselves do not switch in the zero passage, (N) should not be connected, since the additional closing delay otherwise causes the opposite. With an internal ring core current converter, the alternating current flowing via a consumer W1 is compared with the set value from 0.1A to a maximum of 32A and, when exceeded, a relay switches off a consumer W2 connected to 2 within 0.5 seconds or a consumer W3 connected to 3. Adjustment accuracy ±5%. From 25A, the relay always switches on. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. The current base A is set with the lower latching rotary switch A. TLE: 1 Number of contacts as changer: 1 Rated control voltage Us at AC 50 Hz: 230 - W
€62.67
Eltako WSZ15DE-32A AC counter
3-10 days
Electronic AC meter AC counters without approval for support rail. Stand-by loss only 0.5 Watt. Accuracy class B (1) % With S0 interface. This alternating current meter measures the active energy on the basis of the current flowing between the input and the output. The own consumption of only a maximum of 0.5 watt active power is not measured and not displayed. Like all counters without PTB or MID approval in Germany not approved for monetary current billing. Every 30 seconds, the display switches from the accumulated active energy to the instantaneous consumption in Watt for 5 seconds. 1 external conductor can be connected with a current up to 32A. In the event of a load to be expected of more than 50%, a ventilation distance of 1/2 division unit is to be maintained for devices mounted next to it. If the spacer DS12 is used. The starting current is 20ma. The display can only be read with power supply. However, the consumption is non-volatile and will be displayed immediately after a power failure. Two N-terminals for secure cross wiring of several counters. The decimal point which flashes depending on the power consumption indicates a power reference. In case of false connection, false appears in the display. The digital display has 7 digits. Up to 99999,99kWh, two descendants are displayed. From 100000.0kWh only one. Even with only theoretically conceivable maximum current reference, the display would be suitable for more than 15 years. The power reference is displayed with the decimal point. TLE: 1 Certified: No Measurement voltage: 230 W
€63.74
Eltako ETR61NP-230V+FK separation relay
3-10 days
Disconnection relays with window contact 1 closer not potential-free 10A/250V AC, stand-by loss only 0.5 Watt, for installation and AP installation, hybrid technology combines the advantages of wear-free electronic control with the high power of special relays, control input with internally generated low voltage 24W DC, with a disconnection transformer galvanically separated from the power supply and the working contact (PELaisV), therefore no external low voltage. 1 lock not potential-free 10A/250V AC. With window contact. Stand-by loss only 0.5 Watt. For installation. 45mm long, 45mm wide, 18mm deep. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Control input with internally generated low voltage 24W DC. galvanically separated from the power supply and the working contact (PELV). Therefore, no external low-voltage power supply is required. With two L-terminals and 2 N-terminals for easy and fast installation. Power supply 230W. The enclosed window contact consists of a reed relay with connection terminals and a magnet. The normally closed contact opens as soon as the magnet has come closer than 25mm. Connected to the terminals T1 and T2 of the separating relay ETR61NP, the power supply of a rod train is switched on as long as the window is open. The ETR61NP can be placed in the UP-Dose behind the outlet for the Dunstabzug. Installation of the window contact FK: On the housing-painted side, lever the inserts out. Connect Reedrelais and cut out housing section for the line. Both housings maximum 15mm
€65.62