List of products by brand Eltako

Eltako NR12-002-3X230V NEWS
3-10 days
Power monitoring relay for mounting on support rail DIN-EN 60715 TH35, for monitoring 230 W AC voltage against the zero conductor, drop delay adjustable 0.1 to 8 seconds, draw delay 0.5 s, LED display for applied voltage, with the lower rotary switch on the front side two draw-on or respectively. Relapse voltages are set: U1: 161W drop-back voltage and 185V draw voltage U2: 196W drop-back voltage and 206W draw-on voltage according to. WDE 0100 part 718 network monitoring relay with field monitoring. Stand-by loss only 0.8 Watt. Mounting unit for mounting on support rail (2 TE). For monitoring 230W AC voltage between 1 to 3 external conductors and the neutral conductor and for monitoring the rotary field (rotating in the right) in the rotary switch positions 2ph and 3ph. In the position L1/L2/L3, only the rotary field is monitored, regardless of the mains voltage. If L1 fails, the relay will drop immediately without a relapse delay. With the lower rotary switch on the front side, two draw or. Relapse voltages are set and the number of monitored external conductors must be specified. U1: 161W falling voltage and 185V tightening voltage. U2: 196W falling voltage and 206W tightening voltage according to. WDE 0100, Part 718 (formerly: WDE 0108, Part 1). LED display for correct applied voltage. In case of incorrect polarity or a missing external conductor, the LED flashes quickly. Relapse delay RV with the upper rotary switch adjustable from 0.1 to 8 seconds. While the RV time is running, the LED flashes slowly. Suit delay 0.5s. Number of contacts as changer: 2 TLE: 2
€70.35
Eltako S2U12DDX-UC 2-channel clock
3-10 days
2-channel weekly switch clock 1+1 closer potential-free 16A/250V AC, 60 switch clock memory locations, power reserve 2 weeks, stand-by loss max. 0.4 Watt, automatic summer winter time switch and pulsed, with astro function, additional control input for the central on or off 2-channel clock with astro function. Stand-by loss only 0.03-0.4 watts. To this end, simply connect the N conductor to the terminal (N) and L to 1(L) and/or 3(L). This results in an additional stand-by loss of only 0.1 Watt. Due to the use of bistable relays, there is no coil loss power and no heating thereby even in the switched-on state. Up to 60 switching clock memory locations are distributed freely on the channels. With date and automatic summer/winter time conversion. Power reserve without battery about 7 days. Each storage space can be occupied either with the astro function (automatic switching after sunrise or sunset), the switch-on and switch-off time or a pulse switching time (in which a pulse of 2 seconds is triggered). The switch-on or switch-off time Astro can be shifted ± 2 hours and, in addition, from the manufacturing week 19/2012, a time shift of up to ± 2 hours influenced by the sun. With control input +(A1) for central control ON or OFF with priority. Supply voltage and control voltage for central control 8..230V UC. The switching clock is set with the MODE and SET keys and a key lock is possible. Set language: After each application of the supply voltage, the language can be selected with SET within 10 seconds and confirmed with MODE. D = German, GB = English, F = French, IT = Italian and ES = Spanish. Then the normal display appears: weekday, time, day and month. Quick run: In the following settings, the numbers run quickly when the input key is pressed longer
€82.16
Eltako R12-100-12V AC INSTALLATION RELAY
3-10 days
Switching relay for mounting on support rails DIN-EN 60715 TH35 rated switching power 16 A/250 W AC or. 10 A/400 W AC Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W. Number of contacts as closer: 1 Voltage type for actuation: AC TLE: 1 Rated control voltage Us at AC 50 Hz: 12 - W
€19.25
Eltako R12-100-24V AC INSTALLATION RELAY
3-10 days
Switching relay for mounting on support rails DIN-EN 60715 TH35 rated switching power 16 A/250 W AC or. 10 A/400 W AC Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W. Number of contacts as closer: 1 Voltage type for actuation: AC TLE: 1 Rated control voltage Us at AC 50 Hz: 24 - W
€21.61
Eltako R12-100-8V AC INSTALLATION RELAY
3-10 days
Switching relays for mounting on support rails DIN-EN 60715 TH35 Rated switching power 16 A/250 W AC or 10 A/400 W AC Number of contacts as closer: 1 TLE: 1 Rated control voltage Us at AC 50 Hz: 8 - W Voltage type for actuation: AC Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W.
€21.61
Eltako S12-100-8V AC STROMSTOSSCHALEN
3-10 days
Current surge switches for mounting on support rails DIN-EN 60715 TH35 rated switching power 16 A / 250 W AC or. 10 A / 400 W AC with manual actuation and switching position display mechanical storage of the switching position Electromechanical current surge switch with manual actuation and switching position display. Switch-on time 100%. 5-6W. Contact distance 3mm. Distance control connections/contact > 6mm. Suitable for connection to an SELV network. Number of locks: 1 width in division units: 1 dimensioning switching current: 16 A control voltage 1: 8 - W control voltage type 1: AC installation depth: 55 mm assembly type: DIN rail frequency of control voltage 1: 50 - 50 Hz voltage type of supply voltage: AC supply voltage range: 250 - 250 W Max. Bulb load: 2300 W Max. Lamp load: 2300 VA Max. Fluorescent lamp load (Duo circuit): 2300 VA Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 10 A manual operation possible: Yes
€21.61
Eltako S12-100-24V AC POWER SWITCH
3-10 days
Current surge switches for mounting on support rails DIN-EN 60715 TH35 rated switching power 16 A / 250 W AC or. 10 A / 400 W AC with manual actuation and switching position display mechanical storage of the switching position Electromechanical current surge switch with manual actuation and switching position display. Switch-on time 100%. 5-6W. Contact distance 3mm. Distance control connections/contact > 6mm. Suitable for connection to an SELV network. Number of locks: 1 width in division units: 1 dimensioning switching current: 16 A control voltage 1: 24 - W control voltage type 1: AC installation depth: 55 mm assembly type: DIN rail frequency of control voltage 1: 50 - 50 Hz voltage type of supply voltage: AC supply voltage range: 250 - 250 W Max. Bulb load: 2300 W Max. Lamp load: 2300 VA Max. Fluorescent lamp load (Duo circuit): 2300 VA Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 10 A manual operation possible: Yes
€21.61
Eltako R91-100-230VAC INSTALLATION RELAY
3-10 days
Switching relays for can installation and AP mounting with manual actuation and switching position indicator Rated switching power 10 A/250 W AC or 6 A/400 VAC Number of contacts as closer: 1 Rated control voltage Us at AC 50 Hz: 230 - W Electromechanical switching relay with manual actuation and switching position indicator. Switch-on time 100%. 4-5W. Contact distance 2mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W.
€23.02
Eltako R91-100-12VAC INSTALLATION RELAY
3-10 days
Switching relays for can installation and AP mounting with manual actuation and switching position indicator Rated switching power 10 A/250 W AC or 6 A/400 VAC Number of contacts as closer: 1 Rated control voltage Us at AC 50 Hz: 12 - W Electromechanical switching relay 12W. 1 closer 10A/250V AC. For installation and AP mounting with manual actuation and switching position display. 50mm long, 26mm wide, 32mm deep. Switch-on time 100%. 4-5W. Contact distance 2mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W.
€23.02
Eltako S91-100-12VAC STROMSTOSS
3-10 days
Power surge switches for can installation and AP mounting with manual actuation and switching position indicator Rated switch power 10 A/250 W AC or 6 A/400 VAC Dimensions: 26 x 50 x 32 mm Number of locks: 1 Rated switch current: 10 A Control voltage 1: 12 - W Mounting depth: 32 mm Mounting type: Power type of supply voltage: AC Supply voltage range: 250 - 250 W Max. Bulb load: 2300 W Max. Lamp load: 2300 VA Max. Fluorescent lamp load (Duo circuit): 2300 VA Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 10 A manual operation possible: Yes Electromechanical power surge switch with manual actuation and switching position display. Switch-on time 100%. 4-5W. Contact distance 2mm.
€23.25
Eltako S09-12V power surge switch 29100011
3-10 days
Power surge switches with manual actuation and switching position display. Only 1/2 division unit. 5W. For pulse control. Contact distance 3mm. Width in division units: 0.5 Number of changers: 0 Number of switches: 1 Number of openers: 0 Rated switching current: 16 A Control voltage 1: 12 - 12 W Control voltage type 1: AC Installation depth: 55 mm Function: other assembly type: DIN rail Frequency of control voltage 1: 50 - 50 Hz Voltage type of supply voltage: AC Supply voltage range: 250 - 250 W Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 8 A manual operation possible: Yes
€26.67
Eltako R12-200-230V AC INSTALLATION RELAY
3-10 days
Switching relays for mounting on support rails DIN-EN 60715 TH35 Rated switching power 16 A/250 W AC or 10 A/400 W AC Number of contacts as closer: 2 Voltage type for actuation: AC TLE: 1 Rated control voltage Us at AC 50 Hz: 230 - W Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W.
€27.26