List of products by brand Hager

Hager ADS966D FI/LS 1P+N 6kA C-Characteristic 16A 30mA
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: C Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 VRated current16 ATrigger characteristicCRated value6Type of differential protectionASensitivity30 mANumber2 PNumber of modules2Rated operating voltage Ue240 VInsulation voltage500 VImpact strength4,000 VFrequency50 HzTorque2.1NmTotal loss power at rated current5.2 WDevice life, electrical switching games2000Machine life mechanical switching games2000Connection cross section with flexible conductor1 - 16mm2Connection cross section for rigid conductor1 - 25mm2Operating temperature-25 to 40 °CStorage temperature-25 to 70 °CHeight installed product94 mmWide installed product35 mmDeep Installed Product68 mm
€89.92
Hager CDS425D fault current switch 4 polig 6kA 25A 30mA Type A QuickConnect
3-7 working days
EN 61008-1, DIN EN 61008-2-1 and VDE 0664 Part 10 + 11. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11 at access up to 63 A, IP2x touch protection according to DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Suitable for subsequent installation of additional equipment. Nominal current: 25 A Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Impact current strength (impulsive fault currents 8/20μs): 0.25 kA Number of modules: 4 Frequency: 50 Hz Rated current25 AType of differential protectionASensitivity30 mANumber4 PImpact current resistance (pulse fault currents 8/20μs)0,25Number of modules4Frequency50 HzAssembly typeDIN railConnection typeQuickConnectConnection cross section with flexible conductor16mm2Connection cross section for rigid conductor25mm2Torque2.8 NmType of protectionIP20Insulation voltage500 VImpact strength4 kVAdditional equipment possible1Operating temperature-25 to 40 °CMachine life mechanical switching games4000Device life, electrical switching games2000Total loss power at rated current4.5 WDegree of contamination according to IEC 60664 / IEC 60947-22Height above N.N.2000 mRated current at 30° C25 AStorage temperature-55 to 70 °CHeight installed product83 mmWide installed product70 mmDeep Installed Product70 mm
€75.48
Hager ADA563D FI/LS 1P+N 10kA C-13A 30mA Type A
2-5 days
1P+N 10kA C-13A 30mA type A fault current circuit breaker according to EN 61009-1 and EN 61009-2-1. IP2x contact protection according to DIN VDE 0660 part 514. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, Bi-Connect terminals below, external blue test button for half-yearly actuation and fault current display. Easy removal from the phase rail composite. All products with VDE characters. Labeling option directly on the device. Rated current: 13 A Trigger characteristic: C Switching capacity Icn AC according to IEC 60898-1: 10 kA Type of fault current protection: A Rated fault current: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V
€66.53
Hager ADA566D 1P+N 10kA C-16A 30mA Type A
2-5 days
1P+N 10kA C-16A 30mA Type A fault current circuit breaker according to DIN VDE 0664 Part 20 / EN61009-1 and DIN VDE 0664 Part 21 / EN61009-2-1. Contact protection according to DIN VDE 0660 part 514. Bi-Connect terminals below, blue test button and fault current display. Easy removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Rated current: 16 A Trigger characteristic: C Switching capacity Icn AC according to IEC 60898-1: 10 kA Type of fault current protection: A Rated fault current: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V
€66.53
Hager L73M Lasttrennschalter D02 E18 63A AC400V 3polig
2-5 days
3 pole 40A load disconnector for hat rail or mounting plate load disconnector for mounting on hat rail or mounting plate, rotary drive directly on the device in the OFF state can be locked with a padlock. Ensures switching on and off under load and a safety disconnect function in all low-voltage circuits. Rated current: 40 A Rated operating voltage Ue: 380/415 V Isolation voltage: 800 V Number of poles: 3 P Number of modules: 2.57 Operating temperature: -20 ... 70 °C Connection type: Screwing technology Connection cross-section with rigid conductor: 16mm2
€45.74
Hager ESC227 Insta-Schütze 1S 1O 25A/230VACSpule:230VAC
2-5 Tage
Installation Protector 25A 1S+1Ö 230V Protector in compact design according to EN 61095 and DIN VDE 0637-3 as well as contact protection according to DIN VDE 0106 part 100. Contact position display by display window, integrated labeling field and suitable for subsequent installation of additional device. Notes: If several devices are installed directly, a spacer (1/2 PLE) must be installed next to each second device. Rated current: 25 A Control voltage AC current: 230 V Number of modules: 1 Rated operating voltage Ue: 230 V Frequency: 50 Hz Connection type: Screw technology
€37.42
Hager MCS625 cable protection switch 3P+N 6kA C-25A Quick Connect 4M
2-5 Tage
Rated current:25 ATrigger characteristic:CNominal deactivation capacity:6Number of poles:4 PNumber of modules:4AC voltage:OF 230/400 VInsulation voltage:500 VFrequency:50/60 HzConnection type:QuickConnectTorque:2.8 NmTotal power loss under rated current:10.1 WDevice life, electrical switching games:4000Machine life mechanical switching games:20000Operating temperature:-25 to 60 °CStorage temperature:-25 to 80 °CHeight installed product:83.4 mmWide installed product:70 mmDeep Installed Product:70 mm
€86.44
Hager MCS313 LS switch 13A/3pol/C 6kA, QC circuit breaker 3 polig 6kA C-characteristic 13A QuickConnect 3 modules
2-8 days
3polig 6kA C-Characteristic 13A QuickConnect 3 Module cable protection switch with QuickConnect terminal according to DIN EN 60898-1 (VDE 0641 part 11):2003-12; EN 60898-1:2003; EN 60898-1, pr A1:2003, at the exit up to 16A and at the access for the concealment up to 63A. LS with time-delayed thermal trigger for overload protection and electromagnetic trigger for short-circuit protection. Suitable for retrofit installation of additional equipment; Labeling option directly on the device and individual removal from the phase rail connection by unlocking the quick-fitting hat railRated current:13 ATrigger characteristic:CNominal deactivation capacity:6Number of poles:3 PNumber of modules:3AC voltage:OF 230/400 VInsulation voltage:500 VFrequency:50/60 HzConnection type:QuickConnectTorque:2.8 NmTotal power loss under rated current:6.7 WDevice life, electrical switching games:4000Machine life mechanical switching games:20000Operating temperature:-25 to 60 °CStorage temperature:-25 to 80 °CHeight installed product:83.4 mmWide installed product:52.5 mmDeep Installed Product:70 mm
€33.36