Hager VH12AT small distributor HW,Volta, 1x12(+2)TE,IP30, B314xH321xT87mm Version Austria
2-5 days
HWV, Volta and IP30,1x12PLE, version AustriaMounting type: hollow wallMaterial of housing: plasticProtection type: IP30Protection class: Protection class IIGWT glow wire test: 850 °CNumber of distribution rows: 1Number of modules: 12Number of doors: 1Door closure type: snap closureRAL colour number: 9010Color: whiteHeight installed product: 356 mmWide installed product: 348 mmDeep installed product: 94,5 mm
€70.69
Hager GD102N Mini distributor AP,Gamma,1x2TE,o.door,B55xH160xT82mm
2-5 days
Mini distributor IP30 2 space units Mini distributor as micro distributor made of plastic for the installation of row-mounted germs according to the standard DIN 43 880 as protection cover according to BGV A2 for Geraete up to 63 A, 400 V /50 Hz, protection class IP30. For splash mounting with 46 mm barley slot, serially plombable. Mounting type: plasterMaterial of housing: plasticProtection type: IP30Protection class: Protection class IINumber of distribution rows: 1RAL colour number: 9010Number of modules: 2Color: whiteDoor closure type: without closureHeight installed product: 160 mmWide installed product: 55 mmDeep installed product: 82 mm
€9.60
Hager CDA225D fault current switch 2 polig 6kA 25A 30mA Type A
3-8 working days
Residual current circuit breaker 2-pole 6kA 25A 30mA type A. Residual current circuit breaker (FI) according to EN 61008-1, DIN EN 61008-2-1, VDE 0664 part 10 + 11, protection against accidental contact IP2x according to DIN VDE 0106 part 100 .Suitable for retrofitting additional equipment (mounting without tools). Wire push-in protection terminals, bottom bi-connect terminals, external blue test button. All products with VDE mark. Labeling option directly on the device.



Rated current
25A


Type of differential protection
A


Sensitivity
30mA


Number of Poles
2P


Surge current resistance (pulse fault currents 8/20µs)
0.25kA


Number of modules
2


Frequency
50Hz


Mounting type
DIN rail


Type of connection
screw technology


Connection cross section with flexible conductor
16mm²


Connection cross section with rigid conductor
25mm²


torque
2.8Nm


degree of protection
IP20


Insulation voltage
500V


Surge withstand voltage
4kV


Additional equipment possible
1


Operating temperature
-25 to 40 °C


Device lifetime mechanical switching cycles
4000


Device service life, electrical switching cycles
2000


Total power loss under rated current
3.4W


Degree of contamination according to IEC 60664 / IEC 60947-2
2


Height above sea level
2000m


Rated current at 20° C
25A


Rated current at 30° C
25A


Rated current at 35° C
25A


Rated current at 40° C
25A


Rated current at 45° C
25A


Rated current at 50°C
25A


Rated current at 55° C
25A


Rated current at 60°C
25A


Rated current at 65°C
25A


Rated current at 70°C
21A


Storage temperature
-55 to 70 °C


Height installed product
83mm


Wide installed product
35mm


Deep Installed Product
70mm


€68.04
Hager ADS916D FI/LS 1P+N 6kA B-Characteristic 16A 30mA
3-8 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 VRated current16 ATrigger characteristicBRated value6Type of differential protectionASensitivity30 mANumber2 PNumber of modules2Rated operating voltage Ue240 VInsulation voltage500 VImpact strength4,000 VFrequency50 HzTorque2.1NmTotal loss power at rated current5.2 WDevice life, electrical switching games2000Machine life mechanical switching games2000Connection cross section with flexible conductor1 - 16mm2Connection cross section for rigid conductor1 - 25mm2Operating temperature-25 to 40 °CStorage temperature-25 to 70 °CHeight installed product94 mmWide installed product35 mmDeep Installed Product68 mm
€68.84
Hager CFA463D fault current circuit breaker 4 polig 6kA 63A 300mA Type A
3-7 working days
fault current protection switches 4 polig 6kA 63A 300mA type A. fault current protection switches (FI) according to EN 61008-1, DIN EN 61008-2-1, VDE 0664 part 10 + 11, touch protection IP2x according to DIN VDE 0106 part 100. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, Bi-Connect terminals at the bottom, external blue test button. All products with VDE characters. Labeling option directly on the device.Rated current63 AType of differential protectionASensitivity300 mANumber4 PImpact current resistance (pulse fault currents 8/20μs)0,25Number of modules4Frequency50 HzAssembly typeDIN railConnection typeScrew technologyConnection cross section with flexible conductor16mm2Connection cross section for rigid conductor25mm2Torque2.8 NmType of protectionIP20Insulation voltage500 VImpact strength4 kVAdditional equipment possible1Operating temperature-25 to 40 °CMachine life mechanical switching games4000Device life, electrical switching games2000Total loss power at rated current7.7 WDegree of contamination according to IEC 60664 / IEC 60947-22Height above N.N.2000 mRated current at 20° C63 ARated current at 30° C63 ARated current at 35° C63 ARated current at 40° C63 ARated current at 45° C60 ARated current at 50°C58 ARated current at 55° C55 ARated current at 60°C51 ARated current at 65°C48 ARated current at 70°C45 AStorage temperature-55 to 70 °CHeight installed product83 mmWide installed product70 mmDeep Installed Product70 mm
€127.10
Hager ADZ363D FI/LS 3X 1P+N 6kA C character. 13A 30mA Type A QC
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with 3 x 1-pole circuit breaker for 230 V AC circuits and a fault current protection circuit in the compact housing. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 16 A and at the access up to 63 A, contact protection according to IP2x DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 13 A Trigger characteristic: C Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Number of modules: 4 Rated operating voltage Ue: 230 V



Rated current
13 A


Trigger characteristic
C


Rated value
6


Type of differential protection
A


Sensitivity
30 mA


Number
4 P


Number of modules
4


Rated operating voltage Ue
230 V


Insulation voltage
500 V


Frequency
50 Hz


Torque
2Nm


Total loss power at rated current
9.6 W


Device life, electrical switching games
2000


Machine life mechanical switching games
2000


Operating temperature
-5 to 40 °C


Storage temperature
-55 to 70 °C


Height installed product
86 mm


Wide installed product
71 mm


Deep Installed Product
70 mm


€127.20
Hager HTN363E SLS switch 3P E-63A DIN rail
2-7 days
SLS switch 3 polig E-Characteristic 63A for DIN rail mounting. SH switch according to E-DIN VDE 0641-21 and standard DIN 43 880 size 2. SLS in 1- or 3-pole design, one-pole switching, with separate contact position display. For direct mounting on a hat rail. The standard (no suggestions) allows the following limitations: for the customer against unintentional or intentional switching; for the installer with a padlock when working in the plant; for the VNB with plombier wire, padlock or special key.
€151.42
Hager HTS335E SLS switch 3P E-35A busbar QC
2-7 days
SLS switch 3 polig E-characteristic 35A for busbar Quickconnect. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 Size 6. SLS in different pole shape, one-pole switching, with separate contact position display. Plug contacting for direct busbar mounting. The standard multi-function closure allows the following closures: for the customer against unintentional or misconductive switching, for the installer with a padlock when working in the plant, for the WNB with plomb wire, padlock or special key.
€132.61
Hager HAB406 power breaker 4pin 63A
2-5 days
4 pole 63A load disconnector for hat rail or mounting plate load disconnector for mounting on hat rail or mounting plate, rotary drive directly on the device in the OFF state can be locked with a padlock. Ensures switching on and off under load and a safety disconnect function in all low-voltage circuits. Rated current: 63 A Rated operating voltage Ue: 380/415 V Insulation voltage: 800 V Number of poles: 4 P Number of modules: 3.42 Operating temperature: -20 ... 70 °C Connection type: Screwing technology Connection cross-section with rigid conductor: 16mm2
€74.81
Hager HAC306 Power breaker 3pin 63A
2-5 days
Load disconnector 3pin 63A for hat rail or mounting plate Load disconnector for mounting on hat rail or mounting plate, rotary drive directly on the device in the OFF state can be locked with a padlock. Ensures switching on and off under load and a safety disconnect function in all low-voltage circuits. Rated current: 63 A Rated operating voltage Ue: 380/415 V Isolation voltage: 800 V Number of poles: 3 P Number of modules: 3 Operating temperature: -20 ... 70 °C Connection type: Screwing technology Connection cross-section with rigid conductor: 35mm2
€66.70