List of products by brand Hager

Hager MCN316 LS switch 16A/3pol/C 6kA
Hager MCN316 LS switch 16A/3pol/C 6kA
2-5 days
Circuit breaker 3polig 6kA C-Characteristic 16A 3 Modules Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 16 ATrigger characteristic: CNominal shutdown capacity: 6 kANumber of poles: 3 PNumber of modules: 3AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal power loss under rated current: 7 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 52.5 mmDeep installed product: 70 mm
€22.80
Hager KRN163 neutral conductor lead 63A, 1TE
Hager KRN163 neutral conductor lead 63A, 1TE
2-5 days
Nominal current: 63 AInsulation voltage: 500 VFrequency: 50/60 HzTorque: 2,8NmConnection cross-section with flexible conductor: 16mm2Connection cross section for rigid conductor: 25mm2Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83.5 mmWide installed product: 17.5 mmDeep installed product: 60 mm
€7.63
Hager MCS116 LS switch 16A/1pol/C 6kA, QC circuit breaker 1 polig 6kA C-characteristic 16A Quick Connect 1 module
Hager MCS116 LS switch 16A/1pol/C 6kA, QC circuit breaker 1 polig 6kA C-characteristic 16A Quick Connect 1 module
2-5 days
Circuit breaker 1polig 6kA C-characteristic 16A Quick Connect 1 module Cable protection switch with QuickConnect - terminal DIN EN 60898-1 (VDE 0641 part 11):2003-12; EN 60898-1:2003; EN 60898-1, pr A1:2003, at the exit to 16A and access for the deposit up to 63A. Contact protection according to IP2x DIN VDE 0106 part 100 with VDE Signs. LS with time-delayed thermal trigger for Overload protection and electromagnetic trigger for Short circuit protection. Suitable for retrofit cultivation of Additional equipment; Labeling option directly at Device and individual withdrawal from the phase rail composite by unlatching the quick-fit rail mounting. Rated current: 16 A Trigger characteristic: C Nominal shutdown capacity: 6 kA Number of poles: 1 P Number of modules: 1 Operating voltage AC current: 230/400 V Frequency: 50/60 Hz Connection type: QuickConnect
€6.08
Hager MBS516 LS switch 16A/1pol+N/B 6kA,QC QuickConnect B-16A 2M
Hager MBS516 LS switch 16A/1pol+N/B 6kA,QC QuickConnect B-16A 2M
2-5 days
Rated current: 16 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 2 PNumber of modules: 2AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: QuickConnectTorque: 2,8NmTotal loss power at rated current: 5.2 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83.4 mmWide installed product: 35 mmDeep installed product: 70 mm
€13.33
Hager MBN616 LS switch 16A/3pol+N/B 6kA
Hager MBN616 LS switch 16A/3pol+N/B 6kA
2-5 days
3polig+N 6kA B-Characteristic 16A 4 Modules Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 16 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 4 PNumber of modules: 4AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 8.2 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 70 mmDeep installed product: 70 mm
€38.50
Hager ESC225 Insta Protector 2S 25A/230VAC Coil:230VAC
Hager ESC225 Insta Protector 2S 25A/230VAC Coil:230VAC
2-5 days
Installation Protector 25A 2S 230V Protector in compact design, builtin accordance with EN 61095; DIN VDE 0637-3,Contact position display bydisplay window; plombable withplumbing cap(accessories);auxiliary switches areCan be flanged. IntegratedLabel field. Contact protection afterDIN VDE 0106 part 100AC voltage: 230 VNumber of modules: 1Operating temperature: -10 to 50 °CStorage temperature: -40 to 80 °CConnection type: screw technologyConnection cross-section with flexible conductor: 1 - 6mm2Connection cross section for rigid conductor: 1 - 10mm2Contact type: 2S
€20.57
Hager MCS516 LS switch 16A/1pol+N/C 6kA,QC QuickConnect C-16A 2M
Hager MCS516 LS switch 16A/1pol+N/C 6kA,QC QuickConnect C-16A 2M
2-5 days
Rated current: 16 ATrigger characteristic: CNominal shutdown capacity: 6 kANumber of poles: 2 PNumber of modules: 2AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: QuickConnectTorque: 2,8NmTotal loss power at rated current: 5.2 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83.4 mmWide installed product: 35 mmDeep installed product: 70 mm
€11.94
Hager MCS513 LS switch 13A/1pol+N/C 6kA,QC C-13A Quick Connect 2M
Hager MCS513 LS switch 13A/1pol+N/C 6kA,QC C-13A Quick Connect 2M
2-5 days
Circuit breaker 1P+N 6kA C-13A Quick Connect 2MRated current: 13 ATrigger characteristic: CNominal shutdown capacity: 6 kANumber of poles: 2 PNumber of modules: 2AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: QuickConnectTorque: 2,8NmTotal loss power under rated current: 4.6 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83.4 mmWide installed product: 35 mmDeep installed product: 70 mm
€11.94
Hager MBS113 LS switch 13A/1pol/B 6kA, QC QuickConnect
Hager MBS113 LS switch 13A/1pol/B 6kA, QC QuickConnect
2-5 days
Circuit breaker 1polig 6kA B-Characteristic 13A QuickConnect 1 module Circuit breaker with QuickConnect terminal according to DIN EN 60898-1 (VDE 0641 part 11):2003-12; EN 60898-1:2003; EN 60898-1, pr A1:2003, at the exit up to 16A and at the access for the concealment up to 63A. LS with time-delayed thermal trigger for overload protection and electromagnetic trigger for short-circuit protection. Suitable for retrofit installation of additional equipment; Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails.Rated current: 13 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 1 PNumber of modules: 1AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: QuickConnectTorque: 2,8NmTotal power loss under rated current: 2.2 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83.4 mmWide installed product: 17.5 mmDeep installed product: 70 mm
€5.98
Hager MCN120 LS switch 20A/1pol/C circuit breaker 1 polig 6kA C-characteristic 20A 1 module
Hager MCN120 LS switch 20A/1pol/C circuit breaker 1 polig 6kA C-characteristic 20A 1 module
2-5 Tage



Nennstrom:
20 A


Auslösercharakteristik:
C


Nennabschaltvermögen:
6 kA


Polanzahl:
1 P


Anzahl Module:
1


Betriebsnennspannung Wechselstrom:
230/400 V


Isolationsspannung:
500 V


Frequenz:
50/60 Hz


Anschlussart:
Schraubtechnik


Drehmoment:
2,8Nm


Gesamtverlustleistung unter Nennstrom:
2,7 W


Gerätelebensdauer, elektrische Schaltspiele:
4000


Gerätelebensdauer mechanische Schaltspiele:
20000


Betriebstemperatur:
-25 bis 60 °C


Lagerungstemperatur:
-25 bis 80 °C


Höhe installiertes Produkt:
83 mm


Breite installiertes Produkt:
17,5 mm


Tiefe installiertes Produkt:
70 mm


€8.60
Hager MBS116 LS switch 16A/1pol/B 6kA, QC B characteristic 16A Quick Connect 1 module
Hager MBS116 LS switch 16A/1pol/B 6kA, QC B characteristic 16A Quick Connect 1 module
2-5 days
Rated current: 16 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 1 PNumber of modules: 1AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: QuickConnectTorque: 2,8NmTotal loss power at rated current: 2.4 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83.4 mmWide installed product: 17.5 mmDeep installed product: 70 mm
€7.29
Hager L76O load disconnector with fuses D02 63A 3pin+N DIN rail FI-Vorsicherung
Hager L76O load disconnector with fuses D02 63A 3pin+N DIN rail FI-Vorsicherung
2-5 days
D02 63A 3polig+N DIN rail FI-Vorsicherung D0-Safety load disconnector four-pole switch (3pin lockable) for D02 fuses according to OVE EN 60947-3, IEC 60947-3 400V~, 63A, for DIN rail mounting on one level lockable with other modular devices, since the same overall width. With alarm system for safety failure by LED. Screw capless plug-in technology offers permanent contact pressure on the factory. No contact relief during operation. Lockable with padlock and plombable. Removable safety plug with finger protection. For fitting with: D02 sleeve fit insert according to requirements and D0 fuse insert 1...63A Rated current: 63 A Number of poles: 3 P Shock voltage: 6 kV Rated operating voltage Ue: 400 V
€105.60