Best sellers

Hager MBN516 LS switch 16A/1pol+N/B 6kA
2-5 Tage
Circuit breaker 1polig+N 6kA B-Characteristic 16A 2 Modules Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 16 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 2 PNumber of modules: 2AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 4.2 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 35 mmDeep installed product: 70 mm
Kaiser 1211-61
2-5-days


Device connection box for attachment to reinforcement.
1-part with injection-molded front part
with 4 screw domes and 2 spreader claw fields per opening side
fully insulated line transition in combination
Standard combination distance 71 mm




Width 290 mm


depth 95 mm


Installation opening Ø 60 mm


for concrete covers 20-60 mm

Hager MCN516 LS switch 16A/1pol+N/C 6kA
2-5 Tage
Circuit breaker 1polig+N 6kA C-Characteristic 16A 2 Modules Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 16 ATrigger characteristic: CNominal shutdown capacity: 6 kANumber of poles: 2 PNumber of modules: 2AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal power loss under rated current: 4.4 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 35 mmDeep installed product: 70 mm
Eaton PLSM-B13-MW circuit breaker LS switch 242178
2-5 Tage
Eaton LS switch 13A/1pol/B
Cable switchMeasurement switching capacity according to EN 6089810kA, Interconnecting neutral conductor:noProtection type (IP):IP20Construction width:17,5mmSize (according to DIN 43880):1Number of poles:1, triggering characteristic:BMeasurement voltage:230/400AC48DCV, Rated current:13AInstallation depth:60mmType of voltage:AC/DCFrequency:50/60Hz
Kaiser 9063-02 Device hollow wall can O-range T49mm
2-5 days
Device box 49 mm deep (9063-02)
hollow wall socket according to DIN VDE 0606-1 and DIN 49073 made of plastic,
with PlusMinus device screws,
for plate thickness 7-40 mm,
Milling hole Ø 68 mm,
Stationary openings for NYM lines and data lines as well as for pipes Ø 20/25 mm,
Protection class IP 30
Eaton PLN6-B13/1N Leitungsschutzschalter 1TE LS Schalter
2-5 days
Eaton LS switch, 13A/1pol+N/B, 1TE
High-quality cable protection switch 1P+N in 1TE for space-saving installationContact position indicator red-greenClamping aid protectionextensive accessory program retrofittableMeasurement currents up to 40 AMeasurement switching capacity 6 kA according to IEC/EN 60898-1Suitable for outdoor use (conveyor and outdoor distributor) up to - 25°Ctrigger characteristic BNumber of poles (total) 2Rated current 13 AMeasurement voltage 230 VMeasurement switching capacity according to EN 60898 6 kAMeasurement switching capacity Icn according to EN 60898 at 230 V 6 kAMeasurement switching capacity according to IEC 60947-2 0 kAMeasurement switching capacity Icu according to IEC 60947-2 at 230 V 0 kAVoltage type ACEnergy limiting class 3Frequency 50 HzInteractive neutral conductor noOvervoltage category 3Level 2Width in division units 1Installation depth 69.5 mmAdditional equipment possible yesProtection (IP) IP20
Eaton PLSM-C10/1N-MW LS switch 10A/1pol+N/C 242268
2-5 days




Trigger characteristic



C



Number of poles (total)



2



Number of secured poles



2



Rated current


A
10



Measurement voltage


V
230



Measurement switching capacity Icn according to EN 60898 at 230 V


KA
10



Measurement switching capacity Icn according to EN 60898 at 400 V


KA
10



Measurement switching capacity Icu according to IEC 60947-2 at 230 V


KA
0



Measurement switching capacity Icu according to IEC 60947-2 at 400 V


KA
0



Type of voltage



AC



Energy limiting class



3



Frequency


HZ
50 to 60



Interconnecting neutral conductor



yes



Suitable for underground installation



no



Overvoltage category



3



Pollution



2



Width in division units



1.5



Installation depth


mm
ANNEX



Additional equipment possible



yes



Type of protection (IP)



IP20