Best sellers

OBO BETTERMANN V50-3+NPE-280 CombiController V50 three-pin NPE 280V 5093526
OBO BETTERMANN V50-3+NPE-280 CombiController V50 three-pin NPE 280V 5093526
2-5 days
The V50 lightning current combination conductor made of halogen-free plastic is suitable for lightning protection potential compensation according to VDE 0185-305 (IEC 62305). A dynamic separation device and optical status display characterize the modularly pluggable arresters. The NPE variant is additionally equipped with a highly loadable spark gap between zero and protective conductors. The CombiController is particularly suitable for lightning protection potential compensation for buildings of the flash protection class III and IV. The flash current-abableite power is 12.5 kA (10/350) per pole and up to 50 kA (10/350) total. The vibration-proof latching and the voltage and type coding ensure safety and avoid confusion between upper and lower parts. The wedge-shaped design of the contacts allows simple insertion and even simpler removal of the upper parts. Additional technical product information can be obtained quickly and easily via the QR code applied to the power shield.
€398.19
PROTEC.class PKE50 cable entry set 50
PROTEC.class PKE50 cable entry set 50
2-7 days
For laying electrical, telephone and antenna cables in pipe systems by means of sliding glass fiber profiles and various guide heads, maximum tensile load: 100 kg, set contains:3 mm glass fiber profile, 2 front sleeves, 3 guide heads (diameter: 8, 11, 14 mm,) 2 connecting sleeves (for repair handle) 2 pull-in sleeves, 2 cable pull-in stockings (4 seconds - 6 mm)
€335.36
Hager EC350 Energiezähler (Stromzähler) dreiphasig, 1 Tarif, Direktmessung 63A
Hager EC350 Energy meter (electricity meter) three-phase, 1 tariff, direct measurement 63A
Out-of-Stock
Energy meter three-phase, 1 tariff, direct measurement 63A three-phase energy meter for direct measurement of energy consumption up to 63 A with high accuracy (class B). Suitable for use in all network systems. They are equipped with an illuminated digital display that allows the display of energy consumption and power in a resolution of 7 digits including a descending point. A total counter and a partial counter with counter resetting are integrated. The consumption (counter value) can be transmitted remotely by a pulse output. Wiring errors and connection errors are displayed and the measurement data are stored periodically. Connection: Direct connection Operating current: 0.04/63 A Max. Current (I max) of the measuring circuit: 63 A Power consumption: 8.4 VA Number of modules: 4 Frequency: 50/60 Hz
Eaton SPBT12-280-3+NPE Überspannungsableiter 3+NPE 280V, TN-S/TT-Set 158332
Eaton SPBT12-280-3+NPE overvoltage arrester 3+NPE 280V, TN-S/TT set 158332
Out-of-Stock
For the protection of consumer equipment against transient overvoltages caused by direct and indirect flashes, as well as switching operations, application according to IEC 60364-5-53 Section 534, test classes I, II according to IEC 61643-1, SPD type T1, T2 according to EN 61643-11, flash protection class III and IV according to IEC 62305, execution without remote messageNet form-Design of poles3 + N / PRated leakage current (8/20)KA25Rated voltage ACV280Rated voltage DCV0Maximum permanent voltage ACV280Highest continuous voltage DCV0Max. PV voltageV0Protection levelKV0Protection level L-NKV1.5Protection level N-PEKV100Short circuitnoAssembly typeHat rail 35 mmSize5 TEAMax. Conductor cross-section rigid (one/multiple)mm20Max. Conductor cross section flexible (fine)mm20With telecommunication contactnoIntegrated PreservationnoSignaling on the deviceopticalTest class type 2yesType of protection (IP)IP20
OBO BETTERMANN V50-3-280 CombiController V50 three-pin 280V 5093511
OBO BETTERMANN V50-3-280 CombiController V50 three-pin 280V 5093511
2-7 days
The V50 lightning current combination conductor made of halogen-free plastic is suitable for lightning protection potential compensation according to VDE 0185-305 (IEC 62305). A dynamic separation device and optical status display characterize the modularly pluggable arresters. The CombiController is particularly suitable for lightning protection potential compensation for buildings of the flash protection class III and IV. The flash current-abableite power is 12.5 kA (10/350) per pole and up to 50 kA (10/350) total. The vibration-proof latching and the voltage and type coding ensure safety and avoid confusion between upper and lower parts. The wedge-shaped design of the contacts allows simple insertion and even simpler removal of the upper parts. Additional technical product information can be obtained quickly and easily via the QR code applied to the power shield.
€307.77
Dehn 941310 Überspannungsableiter Typ 1+2 3pol+NPE TT 255VAC 4x12,5kA
Dehn 941310 Überspannungsableiter Typ 1+2 3pol+NPE TT 255VAC 4x12,5kA
2-3 days
Stationary ladder DEHNshield TT 2554-pole combination conductor for 230/400 V- TT and TN (C) -S systems,Width 4TEConductor type 1 + type 2 according to EN 61643-11Application-optimized use in compact electrical installationsspark gap technology with downstream current limitation Defective indicator Maximum continuous voltage: 255 V AC Protection level: Flash current (10/350): 50 kA Energetic coordination according to DIN EN 62305-4 Conductor of the Red/Line family, as well as directly to the terminal
€302.50
XYMM-J 5x2,5 50m Bund PVC-Baustellenleitung K35 GE
-5%
XYMM-J 5x2,5 100m Bund PVC-Baustellenleitung K35 GE
2-5 Tage
PVC Baustellenleitung Verwendung: Für den Anschluss von Betriebsmitteln besonders auf Baustellen. In trockenen und feuchten Räumen, im Freien und in explosionsgefährdeten Betrieben.
€295.72
€311.29
Hager VE318DN Vector Distribution IP65 54 PLE QC PE/N
Hager VE318DN Vector Distribution IP65 54 PLE QC PE/N
2-5 days
Vector distributor IP65 54 space units with QucikConnect PE and N clamp small distributor plaster; Installation small plastic distributor, according to DIN VDE 0603 part 1, according to DIN 43871. For installation of devices up to 63 A according to standard DIN 43 880 with 70 mm or 85 mm installation depth, measuring voltage AC 400 V/50 Hz. Consisting of plastic base with galvanized steel profile rail, embossing for metric line insertion sleeves (top, bottom); lateral embossings for connecting sleeves for connecting two or more distributors side by side. Built-in PE/N clamps quick connector; Top with 46 mm slot. Clear view door front flush, right or left adjustable, lockable, distributor flangeable. Installation type: Aufputz Protection class: IP65 Protection class: Protection class II Number of distribution rows: 3 Number of modules: 54Assembly type:CoatingMaterial of housing:PolystyreneType of protection:IP65Protection class:Protection class IINumber of distribution rows:3Number of modules:54Number of doors:1Type of door lock:snap closureColor:stingrayHeight installed product:602 mmWide installed product:418 mmDeep Installed Product:151 mm
€282.00
ABB 2CMA100163R1000 B23 111-100 three-phase counter “steel”, 3 phases, direct connection 65A
ABB 2CMA100163R1000 B23 111-100 three-phase counter “steel”, 3 phases, direct connection 65A
2-7 days
The following values are output via a seven-segment display with up to 7 digits: active energy (class 1), power, currents, voltages (L-L; L-N) and frequency, both per phase and total. The communication can take place via the integrated infrared interface for connecting a KNX module. The energy meter has an output. This can optionally be used as a pulse output for outputting the active energy or as an alarm output. Up to 25 alarm values (swell values with time delay) can be set here. The counter is calibrated according to MID and approved according to IEC. The installation width is 4 DIN modules.
€278.21
Berker 20348989 S1/B.x Floor temperature controller with central piece and sensor, polar white gloss.
Berker 20348989 S1/B.x Floor temperature controller with central piece and sensor, polar white gloss.
2-7 days
floor temperature controller with lock, central piece, wipp switch, Berker S1 / Bfloor temperature controller with lock, central piece, windscreen switch, 2 LED and floor temperature sensor Berker S.1/B.3/B.7 white, shiny - with imprint - regulating knob with temperature range limitation - with in/off switch and 2 LED - with LED for heating and LED for night reduction - with separate connection for night reduction - for example for adjusting drives closed without current - without spreading claws - with plug clamps 10 - 50 °C, 50/60 Hz nominal voltage 250 V~ switching current 10. 1 °C night reduction approx. 5 °C Sensor line length 4 m neutral conductor required! If the temperature is below, the contact closes.
€269.08
PCE 9134044 Wandverteiler Kunststoff Baureihe Anif4 BV 2x16/5 4xSSD M25o VC Pc
-5%
PCE 9134044 Wandverteiler Kunststoff Baureihe Anif4 BV 2x16/5 4xSSD M25o VC Pc
2-5 Tage
Kunstst.-Wandverteiler Modell ANIF4 IP54 320x222x114 10TE1xM25 Verschraubung oben (Kabeldurchm. 13-18mm PG21) grau2xCEE-Steckdose 16A 5p 400V abgesichert ü. 1xLS 16A 3p C4xSK-Steckdose 16A 250V IP54 abgesichert ü. 2xLS 16A 1p C1xFI 63A/4/0.03A (TYP A 40AT) über alle AusgängeLeitungsschutzschalter und FI Fabrikat Eaton ÖVE / VDEVerteiler auf Vario-Connector 5polig 10qmm verdrahtet
€267.90
€282.00