Best sellers

Eaton PLSM-C13-MW LS switch 13A/1pol/C 242204
2-5 days




Trigger characteristic



C



Number of poles (total)



1



Number of secured poles



1



Rated current


A
13



Measurement voltage


V
230



Measurement switching capacity Icn according to EN 60898 at 230 V


KA
10



Measurement switching capacity Icn according to EN 60898 at 400 V


KA
10



Measurement switching capacity Icu according to IEC 60947-2 at 230 V


KA
0



Measurement switching capacity Icu according to IEC 60947-2 at 400 V


KA
0



Type of voltage



AC



Energy limiting class



3



Frequency


HZ
50 to 60



Interconnecting neutral conductor



no



Suitable for underground installation



no



Overvoltage category



3



Pollution



2



Width in division units



1



Installation depth


mm
ANNEX



Additional equipment possible



yes



Type of protection (IP)



IP20


Hager MBN513 LS switch 13A/1pol+N/B 6kA
2-5 Tage
Circuit breaker 1polig+N 6kA B-Characteristic 13A 2 Modules Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 13 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 2 PNumber of modules: 2AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power under rated current: 4.6 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 35 mmDeep installed product: 70 mm
Eaton PLSM-B16-MW circuit breaker LS switch 242180
2-5 Tage
Eaton LS switch 16A/1pol/B
Cable switchMeasurement switching capacity according to EN 6089810kAInteractive neutral conductor:noProtection type (IP):IP20Construction width:17,5mmSize (according to DIN 43880):1Quantity:Trigger characteristic:BMeasurement voltage:230/400AC48DCVMeasurement current:16AInstallation depth:60mmType of voltage:AC/DCFrequency:50/60Hz
Berker 3036 Switch Up
2-5 days
Rated voltage: 250 V ACSwitching current: 10 AXInstallation depth: 31 mmConnection terminals: according to VDE 0632-1for lighting and control circuitwith connectorsA control switch is shown here by way of example.In the case of 2- and 3-pole control switches, other tap switches and glow units are required.