Best sellers

Legrand 407742 DX3 Circuit breaker C-Characteristic, 16A, 1-pole+N, 6kA, 230VAC, 1TE
2-7 days
Legrand Conductor safety switch DX3 according to EN 60898-1, VDE 0641-11, EN 60947-2, 1-pole with switching neutral conductor, C-characteristics, measurement current In 16 A, measurement switching capacity Icn 6 kA according to EN 60898-1, measurement voltage Un 230 VAC, measurement frequency 50/60 Hz, energy limiting class 3, attachment to hat profile rail. Circuit protection switches with C-characteristics are provided for line protection in devices with high switch-on currents (e.g. motors and transformers).
€8.75
Eaton PKNM-16/1N/B/003-G/A-MW FI/LS combination switch 182887
2-5 days
High-quality FI/LS combination switch, power-voltage-independent triggering, line-up compatible, contact position indicator red - green, clamping aid - rear plug protection, extensive accessory program can be retrofitted, large selection of dimension fault currents, free choice of the line-up arrangement at the top and bottom, dimensioning currents up to 40 A, tripping characteristics B, C, dimensioning switching capacity 10 kA, suitable for use in the outdoors (free)
€82.15
Pipelife TXM40 hose flex armored hose medium 40 25m grey 3341-2
2-5 days
Flexible electrical installation pipe for medium mechanical stress, grey similar to RAL 7037, corrugated, impact resistant, made of PVC hard. Tested according to ÖVE/ÖNORM EN 61386-22, classification EN 3341 2, peak pressure resistance > 750N, temperature range -25° to +60°C, delivery form 50m or. 25m Rings, Usage: universal tank pipe, flexible, for laying in concrete, screed, hollow walls and ceilings, on wood and on and under plaster
€39.54
Eaton PLSM-B20/3N-MW LS switch 20A/3pol+N/B 242518
2-5 days




Trigger characteristic



B



Number of poles (total)



4



Number of secured poles



4



Rated current


A
20



Measurement voltage


V
400



Measurement switching capacity Icn according to EN 60898 at 230 V


KA
10



Measurement switching capacity Icn according to EN 60898 at 400 V


KA
10



Measurement switching capacity Icu according to IEC 60947-2 at 230 V


KA
0



Measurement switching capacity Icu according to IEC 60947-2 at 400 V


KA
0



Type of voltage



AC



Energy limiting class



3



Frequency


HZ
50 to 60



Interconnecting neutral conductor



yes



Suitable for underground installation



no



Overvoltage category



3



Pollution



2



Width in division units



4



Installation depth


mm
ANNEX



Additional equipment possible



yes



Type of protection (IP)



IP20


€60.44
Hager MCN132 LS switch 32A/1pol/C 6kA
2-5 Tage
Circuit breaker 1polig 6kA C-characteristic 32A 1 module Circuit protection switch according to DIN VDE 0641Part 11/8.92according to DIN VDE 0106 part 100 with VDESigns. LS with time-verzoegertemthermal exhaust fuOverload protection and electromagneticLoose for short-circuit protection.Suitable for retrofit cultivation ofAdditional equipment.Labeling option directly on the deviceand individual withdrawal fromPhase rail composite by unlockingthe fast attachment of the hat rails.AC voltage: 230/400 VRated current: 32 ATrigger characteristic: CNominal shutdown capacity: 6 kANumber of poles: 1 PInsulation voltage: 500 VNumber of modules: 1Frequency: 50/60 HzConnection type: screw technology
€10.69
Hager MBS116 LS switch 16A/1pol/B 6kA, QC B characteristic 16A Quick Connect 1 module
2-5 days
Rated current: 16 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 1 PNumber of modules: 1AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: QuickConnectTorque: 2,8NmTotal loss power at rated current: 2.4 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83.4 mmWide installed product: 17.5 mmDeep installed product: 70 mm
€7.29
On sale!
Hager MCN313 LS switch 13A/3pol/C 6kA
2-5 days
Circuit breaker 3polig 6kA C-Characteristic 13A 3 Modules Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails.Rated current: 13 ATrigger characteristic: CNominal shutdown capacity: 6 kANumber of poles: 3 PNumber of modules: 3AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 6.3 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 52.5 mmDeep installed product: 70 mm
€27.95
PROTEC.class PHLAK3526BL main line branch terminal
2-7 days
Conductor terminals for mounting on DIN rails, e.g. for small installation distributors and counters acc. WDE 0603. 35/25 mm2. 1-pole. Classy. Mounting on 35 mm support rail according to. EN 60715 / EN 50022. Installation small distributor and counter positions AC 400W. Main line branch terminals WDE 0603-2, connection material for low voltage circuits for household and similar purposes WDE 0613, Part 1 / EN 60998-1. Color coding corresponding to valid vein colors. Mounting horizontally or vertically. Insulation voltage: 1000 W AC / DC for: Overvoltage category III (Uimp = 8 kw, fixed installation,) Level of contamination 2 (e.g. distribution installation). WDE certified (WDE 0613, Part 1 / EN 60998-1): Test current 125 A. Suitable for Cu and Al conductors. Clamp: brass (galvanized). Clamp screws: steel, galvanized. Insulation housing: plastic (polyamide,) impact-resistant, halogen-free. Line connection: - Main line: 10 - 35 mm2 rigid/multi-wire, 3.5 Nm - branch line: 1.5 - 25 mm2 rigid/multi-wire, 2.5 Nm - stripping length: 25 mm. Inputs max. 35 mm2: 2. Outputs max. 25 mm2: 6. Bushing clamp with 2 screws per clamping point, screws with combination slot Pozidriv Z2. Corners rounded. miter protection: IP20, fingerproof
€14.40
E-YY-J 5X6RE Erdkabel schwarz 50 Meter
1-5 Tage
PVC-isolierte Starkstromkabel 0,6/1kV Verwendung: Als Energiekabel für feste Verlegung, vorzugsweise in Kabelkanälen und Innenräumen, im Freien, im Wasser, in Erde, wenn keine nachträglichen Beschädigungen zu erwarten sind.
€270.00