List of products by brand Hager

Hager TG600AL smoke alarm standard KRIWAN Q, 3V DC, white
2-5 days
Smoke detector Standard KRIWAN Q, 3V DC, white. Smoke detectors with small size and attractive design language according to DIN EN 14604 with additional certification according to the increased testing requirements of Q certification based on vfdb guidelines 14-01 “Vereinigung zur Förderung des deutschen Brandschutz” (vfdb). Increased test criteria against the penetration of foreign bodies and increased protection against damp heat, oxidation and EMC, as well as better temperature change stress. Serves for early detection signaling fires with smoke development in the interior. Processor-controlled function self-test (all 10 sec.) and PGSA technology with independent algorythmic night-riggering when disturbing influences occur, such as dust, to maintain functional safety. Large function and reset button through the entire upper cover of the detector. Acoustic signal (85 dB at 3 m) and red flashing LED for alarming. Acoustic signal for battery wake, pollution or interference with acoustic signaling and yellow LED. Timely limited deactivation function of the smoke detection for suppression of deception alarms of the detector for approx. 12 minutes with automatic reset function in normal operation. Error messages can be delayed by 8 hours for 7 days by acknowledgement on the reset button. The fault of a contaminated detection unit cannot be reset as long as the fault message continues to exist in the evaluation unit. Ceiling mounting or wall mounting according to DIN14676. The detector has a camping/caravan registration. Disassembly and theft protection can be activated, then unlocking only with screw rotation with max. Size of 7mm possible. When turning into the socket, the detector is automatically activated.
€37.52
Hager MBN313 LS switch 13A/3pol/B 6kA
2-8 days
Circuit breaker 3polig 6kA B-Characteristic 13A 3 Modules Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 13 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 3 PNumber of modules: 3AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 6.7 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 52.5 mmDeep installed product: 70 mm
€27.95
Hager MCN320 LS switch 20A/3pol/C 3 polig 6kA C-characteristic 20A 3 modules
2-5 days
Rated current: 20 ATrigger characteristic: CNominal shutdown capacity: 6 kANumber of poles: 3 PNumber of modules: 3AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 8.9 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 52.5 mmDeep installed product: 70 mm
€43.96
Hager MCN325 LS switch 25A/3pol/C 6kA C characteristic 25A 3 modules
2-5 days
Rated current: 25 ATrigger characteristic: CNominal shutdown capacity: 6 kANumber of poles: 3 PNumber of modules: 3AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 10,1 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 52.5 mmDeep installed product: 70 mm
€49.18
Hager EE830 motion detector 200 IP55 white
2-5 days
outdoor motion detector lighting control in commercial buildings and residential buildings by recording moving persons. detection range of 200° and a range of max. 16m at a recommended mounting height of 2.5m. Horizontal lens adjustment of +/- 80° and vertical lens adjustment of 0-30°. detection using Fresnel lenses. Limiting the monitoring area by means of included apertures possible. The time delay and the brightness value are set directly on the device, a pulse can also be generated. Mounting on ceiling and corners using optional mounting adapter EE825 or. EE827 possible.Assembly type:CoatingDetection angle:200 °CType of protection:IP55max. Assembly chair:4 mDiameter field on floor:16 mContact loadability:AC1Contact type:1W + NSwitching power bulbs:1500 WBrightness measurement range:5 / 1000 LuxControl of sensitivity:noSupply voltage:230V +10% / -15%Frequency:50 HzColor:whiteHeight installed product:2.5 m
€64.03
Hager ADZ313D FI/LS 3X 1P+N 6kA B character. 13A 30mA Type A QC
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with 3 x 1-pole circuit breaker for 230 V AC circuits and a fault current protection circuit in the compact housing. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 16 A and at the access up to 63 A, contact protection according to IP2x DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 13 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Number of modules: 4 Rated operating voltage Ue: 230 VRated current13 ATrigger characteristicBRated value6Type of differential protectionASensitivity30 mANumber4 PNumber of modules4Rated operating voltage Ue230 VInsulation voltage500 VFrequency50 HzTorque2NmTotal loss power at rated current9.6 WDevice life, electrical switching games2000Machine life mechanical switching games2000Operating temperature-5 to 40 °CStorage temperature-55 to 70 °CHeight installed product86 mmWide installed product71 mmDeep Installed Product70 mm
€129.00
Hager ERC216 Installation relays , 16A, 2S, 230V
2-5 days
Installation relays for pulse control of circuits up to max. 16 A, according to EN 61095 and DIN VDE 0637-3 as well as contact protection according to DIN VDE 0106 part 100. With contact position display by display window, integrated labeling field and suitable for subsequent installation of additional device. Notes: If several devices are installed directly, a spacer (1/2 PLE) must be installed next to each second device.Contact type: 2S nominal current: 16 AControl voltage AC current: 230 V Number of modules: 1 Rated operating voltage Ue: 230 V Frequency: 50/60 Hz
€38.25
Hager ADG966D FI/LS 16A/1+N/C/30mA G/A fault current circuit breaker 1P+N 6kA C-16A 30mA A-G type
2-5 days
Rated current: 16 ATrigger characteristic: CNominal shutdown capacity: 6 kAType of differential protection: A GSensitivity: 30 mANumber of poles: 2 PNumber of modules: 2AC voltage: 240 VInsulation voltage: 500 VImpact strength: 4000 VFrequency: 50 HzConnection type: screw technologyTorque: 2.1NmTotal loss power at rated current: 5.2 WDevice life, electrical switching games: 2000Machine life mechanical switching games: 2000Connection cross section for flexible conductor: 1 - 16mm2Connection cross section for rigid conductor: 1 - 25mm2Operating temperature: -25 to 40 °CStorage temperature: -25 to 70 °CHeight installed product: 83 mmWide installed product: 35 mmDeep installed product: 68 mm
€74.50