List of products by brand Hager
There are 247 products.
Hager SBT116 Switch 1P 16A with indicator lamp
2-5 days
Switch with LED indicator lamp according to EN 60669-1/669-2-4 with VDE characters, IP2x touch protection after BGV A3. Suitable for retrofit installation of additional equipment; Labeling option directly on the device. Rated current: 16 ANumber of poles: 1 PNumber of modules: 1AC voltage: 230 VInsulation voltage: 440 VImpact strength: 4000 VFrequency: 50/60 HzConnection type: screw technologyTotal loss power at rated current: 0.4 WMachine life mechanical switching games: 200000Connection cross section for flexible conductor: 1.5 - 10mm2Connection cross section for rigid conductor: 1.5 - 16mm2Operating temperature: -20 to 50 °CStorage temperature: -40 to 80 °CHeight installed product: 83 mmWide installed product: 17.5 mmDeep installed product: 68 mm
€30.00
Hager ST303 Bladel Transformer prim. 230VAC sec. 8/12VAC 8VA 2TE
2-5 days
Performance: 8 VAOutput voltage: 8/12 VNumber of modules: 2AC voltage: 230 VInsulation voltage: 4000 VFrequency: 50 HzTotal power loss under rated current: 2.2 WConnection cross section for flexible conductor: 4mm2Connection cross section for rigid conductor: 6mm2Operating temperature: -20 to 35 °CHeight installed product: 111 mmWide installed product: 35 mmDeep installed product: 65 mm
€38.18
Hager KJ04Z cover, plombable, for KJ10S
2-8 days
Height installed product110 mmWide installed product130 mmDeep Installed Product37 mm
€15.72
Hager ADS906D FI/LS 1P+N 6kA B-Characteristic 6A 30mA
2-5 days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 6 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V
Rated current
6A
Trigger characteristic
B
Rated value
6
Type of differential protection
A
Sensitivity
30 mA
Number
2 P
Number of modules
2
Rated operating voltage Ue
240 V
Insulation voltage
500 V
Impact strength
4,000 V
Frequency
50 Hz
Torque
2.1Nm
Total loss power at rated current
1.9 W
Device life, electrical switching games
2000
Machine life mechanical switching games
2000
Connection cross section with flexible conductor
1 - 16mm2
Connection cross section for rigid conductor
1 - 25mm2
Operating temperature
-25 to 40 °C
Storage temperature
-25 to 70 °C
Height installed product
94 mm
Wide installed product
35 mm
Deep Installed Product
68 mm
Rated current
6A
Trigger characteristic
B
Rated value
6
Type of differential protection
A
Sensitivity
30 mA
Number
2 P
Number of modules
2
Rated operating voltage Ue
240 V
Insulation voltage
500 V
Impact strength
4,000 V
Frequency
50 Hz
Torque
2.1Nm
Total loss power at rated current
1.9 W
Device life, electrical switching games
2000
Machine life mechanical switching games
2000
Connection cross section with flexible conductor
1 - 16mm2
Connection cross section for rigid conductor
1 - 25mm2
Operating temperature
-25 to 40 °C
Storage temperature
-25 to 70 °C
Height installed product
94 mm
Wide installed product
35 mm
Deep Installed Product
68 mm
€74.40
€36.00