Eltako

Eltako SNT14-24V/12W power supply 24V DC/12W
3-10 days
Short circuit: Yes Mounting height: 18 mm 1. Output voltage: 24 - 24 W Voltage type of supply voltage: DC Max. Output current 1: 1 A output voltage adjustable: No Rated voltage at AC 50 Hz: 230 - 230 W Stabilized: Yes Direct mounting possible: No Electrical connection: Screw connection Output voltage controlled: Yes Power output: 12 W Suitable for series installation: Yes Support rail mounting possible: Yes Wall mounting possible: No Protection type (IP): IP20 Height: 58 mm Width: 18 mm Depth: 58 mm Power supply for 24V actuators. Nominal power 12W. Stand-by loss only 0.2 Watt. DIN-EN 60715 TH35 for mounting on support rail. 1 division unit = 18mm wide, 58mm deep. With a load greater than 50% of the rated power and always with adjacent switching power supply components greater than 12 watts of rated power, and with dimmers, a 1/2 division unit is required on both sides with the distance pieces DS12. Input voltage 230W -(20% to +10) % efficiency 86%. Stabilized output voltage ±1%, low residual ripple. Short circuit. Overload and overtemperature protection by switching off with automatic switching on after eliminating errors (autorecovery function). The 24W DC output of these switched-mode power supplies is at the bottom so that a fast connection to the FAE14LPR actuators for 24W DC actuators can be established with the busbars SAS-. The SNT14 is always mounted to the right next to the last actuator FAE14LPR, since no plug-in bridge is provided. Power supply for 24V actuators. Stand-by loss only 0.2 Watt. With a load greater than 50% of the rated power and always with adjacent switching power supply components greater than 12 watts of rated power, and with dimmers, a 1/2 division unit is required on both sides with the distance pieces DS12. Efficiency 86%. Stabilized output voltage ±1%, low residual ripple. Short circuit. Overload and overtemperature protection by switching off
€45.83
Eltako SNT14-24V/24W Switching Power Supply 24V DC/24W
3-10 days
Short circuit: Yes 1st output voltage: 24 - 24 W voltage type of supply voltage: DC Max. Output current 1: 1 A output voltage adjustable: No Rated supply voltage at AC 50 Hz: 230 - 230 W Stabilized: Yes Electrical connection design: Screw connection output voltage regulated: Yes Power consumption: 0.2 VA Power output: 24 W Suitable for series installation: Yes Support rail mounting possible: Yes Wall mounting possible: No Protection type (IP): IP20 Height: 58 mm Width: 36 mm Depth: 58 mm Power supply for 24V. Rated power 24W. Stand-by loss only 0.2 Watt. DIN-EN 60715 TH35 for mounting on support rail. 2 division units = 36mm wide, 58mm deep. With a load greater than 50% of the rated power and always with adjacent switching power supply components greater than 12 watts of rated power, and with dimmers, a 1/2 division unit is required on both sides with the distance pieces DS12. Input voltage 230W -(20% to +10) % efficiency 87%. Stabilized output voltage ±1%, low residual ripple. Short circuit. Overload and overtemperature protection by switching off with automatic switching on after eliminating errors (autorecovery function). The 24W DC output of these switched-mode power supplies is at the bottom so that a fast connection to the FAE14LPR actuators for 24W DC actuators can be established with the busbars SAS-. The SNT14 is always mounted to the right next to the last actuator FAE14LPR, since no plug-in bridge is provided. Power supply for 24V actuators. Stand-by loss only 0.2 Watt. With a load greater than 50% of the rated power and always with adjacent switching power supply components greater than 12 watts of rated power, and with dimmers, a 1/2 division unit is required on both sides with the distance pieces DS12. Efficiency 86%. Stabilized output voltage ±1%, low residual ripple. Short circuit. Overload and overtemperature protection by automatic shutdown
€56.17
Eltako SNT61-230V/12VDC-0.5A switching power supply
3-10 days
Switching power supplies for mounting on support rail DIN-EN 60715 TH3Stand-by-loss 0.2 Watt, short-circuit-proof, with a load greater than 50% of the rated power and always with adjacent switching power supplies above 12 Watt rated power, and with dimmers a 1/2 division of ventilation distance with the spacers DS12 is required, input voltage 230W AC, -(20% to +10)%, efficiency 12W DC 83%, 24W DC. For installation. 45mm long, 45mm wide, 33mm deep. Input voltage 230W -(20% to +10) % efficiency 81%. Stabilized output voltage ±1%, low residual ripple. Short circuit. Overload and overtemperature protection by switching off with automatic switching on after eliminating errors (autorecovery function). Measurement current: 0.5 A
€44.36
Eltako SS12-110-12V STROMSTOSS SERIES SWITCH
3-10 days
Switchgear, Series 12 For DIN EN 50022, rated switching power 16 A/250 W AC or 10 A/400 W AC. Power surge series switches with manual actuation and switch position display. Switch-on time 100%. 5-6W. Contact distance 3mm. Distance control connections/contact > 6mm. Suitable for connection to an SELV network. Width in division units: 1 Number of changers: 0 Number of switches: 2 Number of openers: 1 Rated switching current: 16 A Control voltage 1: 12 - 12 W Control voltage type 1: AC Installation depth: 55 mm Function: other assembly type: DIN rail Frequency of control voltage 1: 50 - 50 Hz Voltage type of supply voltage: AC Supply voltage range: 250 - 250 W Max. Bulb load: 2300 W Max. Lamp load: 2300 VA Max. Fluorescent lamp load (Duo circuit): 2300 VA Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 10 A manual operation possible: Yes
€24.69
Eltako SS12-110-230V AC STROMSTOSS SERIES SCALE
3-10 days
Switchgear, Series 12 For DIN EN 50022, rated switching power 16 A/250 W AC or 10 A/400 W AC. Serial switch Width in division units: 1 Number of changers: 0 Number of switches: 2 Number of openers: 1 Rated switching current: 16 A Control voltage 1: 230 - 230 W Control voltage type 1: AC Installation depth: 55 mm Function: other assembly type: DIN rail Frequency of control voltage 1: 50 - 50 Hz Voltage type of supply voltage: AC Supply voltage range: 250 - 250 W Max. Bulb load: 2300 W Max. Lamp load: 2300 VA Max. Fluorescent lamp load (Duo circuit): 2300 VA Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 10 A manual operation possible: Yes Current surge series switches with manual actuation and switching position display. Switch-on time 100%. 5-6W. Contact distance 3mm. Distance control terminals/contact > 6mm.
€24.69
Eltako TGI12DX-UC time relay
3-10 days
Multifunction time relays for mounting on support rail DIN-EN 60715 TH35, for all control voltages from 8 to 230W DC and AC (50/60 Hz), times between 0.1 seconds and 40 hours with the time bases 0.1, 0.5, 2 and 5 seconds, 1, 2 and 5 minutes, 1, 2 and 4 hours and the multiplier of 1-10 are adjustable, contact circuit in the zero crossing of the sine wave, 0.1A. Time range from/to: 40 - 0.1 function: clock generator with pulse starting number of switches: 1 switching power incandescent lamps: 2000 W width in division units: 1 supply voltage range: 8 - 230 W switching power fluorescent lamps inductor: 1000 VA installation height: 58 mm switching power fluorescent lamps DUO: 1000 VA actuation type: analog with single function 1. Time unit: minutes/hour Mounting type: DIN rail Analog adjustable time relay. Stand-by-loss only 0.02 - 0.4 Watt. This analog adjustable time relay is identical to the multifunction time relay, but has only one function. In the TGI12DX-UC type, a second multiplier t1 and t2 can be set separately at the same time basis. To this end, simply connect the N conductor to the terminal (N) and L to 15 (L). This results in an additional stand-by consumption of only 0.1 Watt. Universal control voltage 8..230V UC. Supply voltage like the control voltage. Time range from 0.1 seconds to 40 hours. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. The light-emitting diode under the large rotary switch informs about the contact position during the time sequence.
€47.21
Eltako TLZ12-8 Staircase Time Clock
3-10 days
Rated voltage: 50 %. Bulb load: 2000 W Max. Lamp load: 1000 VA Max. Fluorescent lamp load (Duo circuit): 1000 VA Max. Fluorescent lamp load (parallel compensated): 500 VA stairlight time switch, without switch-off warning. Stand-by-loss only 0.7 Watt. Time setting about 0.2 to 12 minutes. Own continuous light switch with the large rotary switch. For 3- and 4-wire circuits, switchable, with attic lighting at 4-wire circuit. Automatic detection of the circuit type. Without disconnection and contact circuit in the zero passage. With double connections for probe and lamp, so that it can be connected either at the top and bottom or only at the bottom.
€32.06
Eltako TLZ12-8PLUS Stair Time Switch
3-10 days
Number of hours:. Bulb load: 400 W Max. Fluorescent lamp load (parallel compensated): 400 VA stairlight time switch with switch-off warning and pushbutton continuous light can be switched on. Stand-by-loss only 0.7 Watt. With ESL optimization and multifunction. Contact circuit in the zero passage for protecting the contacts and lamps. In particular, this extends the service life of energy-saving lamps. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. In addition, with galvanically separated universal control voltage. Automatic detection of the circuit type. Glow lamp current up to 50ma, depending on the ignition voltage of the glow lamps. Precise time setting 1 to 30 minutes with minute scale. Permanent light switch with the large rotary switch. After a power failure in the function setting
€42.89
Eltako TLZ12-9 Stairlight Time Switch
3-10 days
Steplight time switch, electronic for mounting on support rail DIN-EN 50 022, for older installations, for the control voltage 230W AC, very low switching noise, Glow lamp current 50ma, for 3-wire circuits, not switchable, without autom. Detection of the circuit type, with a relay for 2300W incandescent lamp load, continuous light switch, switch-off warning and push-button continuous light, contact circuit in the zero passage of the sine wave to the device and lamp-saving width in division units: 1 drop-back delay: 1 - 10 min Number of switches: 1 control voltage 1: 230 - W measurement switch current: 10 A control voltage type 1: AC. Bulb load: 2000 W Max. Lamp load: 1000 VA Max. Fluorescent lamp load (Duo circuit): 1000 VA Max. Fluorescent lamp load (parallel compensated): 500 VA stairlight time switch with switchable switch-off warning. Stand-by-loss only 0.7 Watt. Contact circuit in the zero passage for protecting the contacts and lamps. In particular, this extends the service life of energy-saving lamps. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Control, supply and switching voltage 230W. Glow lamp current up to 50ma depending on the ignition voltage of the glow lamps. Precise time setting 1 to 12 minutes with minute scale. Own continuous light switch with the large rotary switch. For 3-wire circuits with attic lighting, not switchable. Only for retrofit
€42.39
Eltako TLZ12D-plus stairlight time switch
3-10 days
Steplight time scale for mounting on support rail DIN-EN 60715 TH35, 16 A/250 V AC not potential-free, incandescent lamps up to 2300 W, ESL and LED lamps up to 200 W, control voltage 230 V and/or 8..230 V UC, switch off pre-warning and pushbutton continuous light, standby loss adjustable only 0.5 Watt. Stand-by-loss only 0.7 Watt. With ESL optimization and multifunction. The functions and times are entered according to the user manual with the MODE and SET keys and displayed digitally on the -LC display. A key lock is possible. Contact circuit in the zero passage for protecting the contacts and lamps. In particular, this extends the service life of energy-saving lamps. The noiseless electronics do not harass the most sensitive ear, unlike many synchronous motors with mechanical transmission. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Control, supply and switching voltage 230V. In addition with galvanically separated universal control voltage 8..230V UC. For 3- and 4-wire circuits, switchable, with attic lighting at 4-wire circuit. Automatic detection of the circuit type. Glow lamp current up to 50mA, depending on the ignition voltage of the glow lamps. Precise time setting 1 to 99 minutes. Own continuous light button with the protruding button SET in the functions TLZ, ESV, ES and ER. With motion detector control input BM, which converts the input signal into a control pulse in the function TLZ. Width in division units: 1 Relapse delay: 1 - 1 min Function: electronic with multifunction Assembly type: DIN rail Number of locks: 1 Control voltage 1: 230 - 23
€49.28
Eltako TLZ61NP-230V Stair Time Switch
3-10 days
Steplight time switch, electronic for installation and AP installation, 10A/250V AC, control voltage 230W AC, Glow lamp current 50ma, with pumps, switch-off warning and pushbutton continuous light, in addition the function: current surge switch with drop-back delay ESW, contact circuit in the zero crossing of the sine wave to the device and lamp-saving stairlight time switch 230W. 1 lock not potential-free 10A/250V AC, incandescent lamps up to 2000W, ESL and LED lamps up to 200W, switch-off warning and push-button continuous light. Stand-by-loss only 0.7 Watt. With ESL optimization.For installation. 45mm long, 45mm wide, 18mm deep. Contact circuit in the zero passage for protecting the contacts and lamps. In particular, this extends the service life of energy-saving lamps. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Control, supply and switching voltage 230W. Time setting 1 to 12 minutes. Glow lamp current up to 50ma, depending on the ignition voltage of the glow lamps. For 3- and 4-wire circuits, switchable, with attic lighting at 4-wire circuit. Automatic detection of the circuit type. After a power failure, the illumination is switched on again when the time sequence has not yet been completed. When switched off, the lighting flickers approx. 30 seconds before the time sequence beginning and a total of 3 times in shorter time intervals. When the pushbutton permanent light is switched on, it is possible to set for longer than 1 second by means of buttons, which is switched off automatically after 60 minutes or can be switched off with buttons for longer than 2 seconds. If the pushbutton continuous light and the switch-off pre-warning are switched on, the switch-off pre-warning takes place after the switch-off of the continuous light. Become a full or part
€38.46
Eltako TLZ61NP-8..230VUC Stair switch. UP
3-10 days
Steplight time switch, electronic for UP mounting, built-in device quietly and timely, max. 50ma Glow lamp current, time range stepless to 10 minutes adjustable, 4-wire switchable, rated switching power 10 A/250 W AC, control voltage 8...230 W UC Stair switch 230V+UC. 1 lock not potential-free 10A/250V AC, incandescent lamps up to 2000W, ESL and LED lamps up to 200W, switch-off warning and push-button continuous light. Stand-by-loss only 0.7 Watt. With ESL optimization. For installation. 45mm long, 45mm wide, 18mm deep. Contact circuit in the zero passage for protecting the contacts and lamps. In particular, this extends the service life of energy-saving lamps. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Control, supply and switching voltage 230W. In addition with galvanically separated universal control voltage 8..230V UC. Time setting 1 to 12 minutes. Glow lamp current up to 50ma, depending on the ignition voltage of the glow lamps. For 3- and 4-wire circuits, switchable, with attic lighting at 4-wire circuit. Automatic detection of the circuit type. After a power failure, the illumination is switched on again when the time sequence has not yet been completed. When switched off, the lighting flickers approx. 30 seconds before the time sequence beginning and a total of 3 times in shorter time intervals. When the pushbutton permanent light is switched on, it is possible to set for longer than 1 second by means of buttons, which is switched off automatically after 60 minutes or can be switched off with buttons for longer than 2 seconds. If the pushbutton continuous light and the switch-off pre-warning are switched on, the switch-off pre-warning takes place after the switch-off of the continuous light. All or part of
€39.93