Eltako

Eltako ETR61NP-230V separation relay
3-10 days
Frequency range: 50 - 50 Hz Nominal voltage: 230 W Mounting type: other central input: Yes No Number of connectable motors: 1 Switching current: 10 A separator relay 230W. 1 lock not potential-free 10A/250V AC. Stand-by loss only 0.5 Watt. For installation. 45mm long, 45mm wide, 18mm deep. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Control input with internally generated low voltage 24W DC. galvanically separated from the power supply and the working contact (PELV). Therefore, no external low-voltage power supply is required. With two L-terminals and 2 N-terminals for easy and fast installation. Power supply 230W.
€31.48
Eltako ETR61NP-230V+FK separation relay
3-10 days
Disconnection relays with window contact 1 closer not potential-free 10A/250V AC, stand-by loss only 0.5 Watt, for installation and AP installation, hybrid technology combines the advantages of wear-free electronic control with the high power of special relays, control input with internally generated low voltage 24W DC, with a disconnection transformer galvanically separated from the power supply and the working contact (PELaisV), therefore no external low voltage. 1 lock not potential-free 10A/250V AC. With window contact. Stand-by loss only 0.5 Watt. For installation. 45mm long, 45mm wide, 18mm deep. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Control input with internally generated low voltage 24W DC. galvanically separated from the power supply and the working contact (PELV). Therefore, no external low-voltage power supply is required. With two L-terminals and 2 N-terminals for easy and fast installation. Power supply 230W. The enclosed window contact consists of a reed relay with connection terminals and a magnet. The normally closed contact opens as soon as the magnet has come closer than 25mm. Connected to the terminals T1 and T2 of the separating relay ETR61NP, the power supply of a rod train is switched on as long as the window is open. The ETR61NP can be placed in the UP-Dose behind the outlet for the Dunstabzug. Installation of the window contact FK: On the housing-painted side, lever the inserts out. Connect Reedrelais and cut out housing section for the line. Both housings maximum 15mm
€54.68
Eltako EUD12D-UC power surge dimming switch
3-10 days
Universal Bus Dimming Switch for mounting on DIN-EN 60715 TH35 Power MOSFET up to 400 W, for lamps up to 400 W, depending on the ventilation conditions, dimmable energy saving lamps ESL and dimmable 230 V-LED lamps additionally depending on the lamp electronics, automatic lamp detection, minimum or maximum brightness and dimming speed adjustable, children's room and slumber circuit width. Stand-by loss only 0.3 Watt. Minimum brightness, maximum brightness and dimming speed adjustable. With children's room and slumber circuit. 1 division unit. Universal dimming switch for lamps up to 400W, depending on the ventilation conditions. Dimmable energy-saving lamps and dimmable 230V LED lamps additionally depend on lamp electronics. Up to 3600W with power inputs at terminals X1 and X2. The control inputs are galvanically separated from the supply and switching voltage. Switching in the zero passage with soft-on and soft-out for lamp protection. In the event of a power failure, the switching position and the brightness stage are stored and is switched on when the supply voltage is returned. From 110W control voltage glow lamp current 5ma (not at RTD). Automatic electronic overload protection and overtemperature shutdown. The functions and times are entered according to the user manual with the MODE and SET keys and displayed on the LC display. A key lock is possible.
€64.52
Eltako EUD12DK/800W-UC Universal Dimming Switch
3-10 days
Universal dimming switch with rotary knob, Power MOSFET up to 800W. Automatic lamp detection. Stand-by loss only 0.2 Watt. Minimum brightness and maximum brightness adjustable. DIN-EN 60715 TH35 for mounting on support rail. 2 division units = 36 mm wide, 58 mm deep. Universal dimming switch for lamps up to 800W, depending on the ventilation conditions, dimmable energy saving lamps ESL and dimmable 230V LED lamps additionally depending on the lamp electronics. Up to 3600W with power inputs LUD12 at the terminals X1 and X2. Universal control voltage 8..230V UC Mounting type: REG Color: blue Operation type: rotary knob Halogen-free: Yes Composition: other load type: universal Serial dimmer: No Conveyor input: No Light value store: Yes Applicable with button: Yes Applicable with motion detector: No Applicable with presence detector: No Applicable with timer/timer: No Applicable with radio button: No. Automatic lamp detection. Stand-by loss only 0.2 Watt. Minimum brightness and maximum brightness adjustable. DIN-EN 60715 TH35 for mounting on support rail. 2 division units = 36mm wide, 58mm deep. Universal dimming switch for lamps up to 800W, depending on the ventilation conditions, dimmable energy saving lamps ESL and dimmable 230V LED lamps additionally depending on the lamp electronics. Up to 3600W with power add-ons LUD12 at the connections X1 and X2. Universal control voltage 8..230V UC, galvanically isolated from supply and switching voltage 230W. No minimum load required. PWM control with 10-24V DC to d
€106.23
Eltako EUD12NPN-UC Electric shock dimming switch
3-10 days
Universal dimming switch for mounting on support rail DIN-EN 60715 TH35 Power MOSFET up to 400 W, for lamps up to 400 W, depending on the ventilation conditions, dimmable energy-saving lamps ESL and dimmable 230 V-LED lamps additionally depending on lamp electronics, automatic lamp detection, minimum or maximum brightness and dimming speed adjustable, children's room and slumber circuit universal dimming switch. Automatic lamp detection. Stand-by loss only 0.1 Watt. Minimum or maximum brightness and dimming speed adjustable. With children's room and slumber circuit. Universal dimming switch, depending on the ventilation conditions. Dimmable energy-saving lamps ESL and dimmable 230V LED lamps additionally depend on lamp electronics. Switching in the zero passage with soft-on and soft-out for lamp protection. Universal control voltage, galvanically isolated from the supply and switching voltage. No minimum load required. Short control commands turn on/off, permanent control changes the brightness up to the maximum value. An interruption of the control changes the dimming direction. The set brightness level remains stored when switching off (memory). In the event of a power failure, the switching position and the brightness stage are stored and is switched on when the supply voltage is returned. From 110W control voltage glow lamp current 5ma. Automatic electronic overload protection and overtemperature shutdown. Width in division units: 1 Number of outputs: 1 Output power from/to: 400 - W Voltage range: 230 - W Power supply usable: Yes Bus system EIB/KNX: No Bus system Radio bus: No Bus system Powernet: No Bus connection included: No Bus system LON: No Other bus systems: without on-site/hand operation: Yes With LED display: Yes Parallel operation possible: No
€53.71
Eltako EUD61M-8..230V UC power surge dimmer UP
3-10 days
Multifunction universal dimming switch for installation and AP mounting for R, L and C loads up to 400 W, Power MOSFET up to 400 W, dimmable energy saving lamps ESL up to 100 W, depending on the ventilation conditions, automatic lamp detection, standby loss only 0.1 W, minimum brightness adjustable, child's room and slumber circuit, standby loss only 0.1 Watt. Power MOSFET up to 400W. Automatic lamp detection. Stand-by loss only 0.1Watt. Minimum brightness adjustable. With children's room and slumber circuit. For installation. 45mm long, 45mm wide, 18mm deep. Universal dimming switch for lamps up to 400W, depending on the ventilation conditions. Dimmable energy-saving lamps and dimmable 230V LED lamps additionally depend on lamp electronics. Switching in the zero passage with soft-on and soft-out for lamp protection. Universal control voltage 8..230V UC, galvanically isolated from supply and switching voltage 230W. Short control commands turn on/off, permanent control changes the brightness up to the maximum value. An interruption of the control changes the dimming direction. The set brightness level remains stored in the memory functions when switching off. In the on-max functions is always switched on with maximum brightness level. In the event of a power failure, the switching position and the brightness stage are stored and is switched on when the supply voltage is returned. Automatic electronic overload protection and overtemperature shutdown. With the
€49.77
Eltako EUD61NP-230V Universal Dimming Switch
3-10 days
Universal power surge dimming switch for installation and AP mounting for R, L and C loads up to 400 W depending on the ventilation conditions, autom. detection of load type R+L or R+C, with %-Drehschalter the minimum brightness (fully dimmed) can be set, the set brightness stage remains stored when switching off, automatic electronic overload protection and over temp shutdown, children's room and slumber circuit, switching in zero-crossing with soft-on and soft-out for lamp protection, control inputs for light scanners, etc. Light switch, without N connection, stand-by loss only 0.7 W universal dimming switch 230V without N connection. Without N connection, Power MOSFET up to 400W. Stand-by loss only 0.5 Watt. With control inputs for light sensor and light switch. For installation. 45mm long, 45mm wide, 18mm deep. Universal dimming switch for R, L and C loads up to 400W, depending on the ventilation conditions. Automatic detection of load type R+L or R+C. Energy saving lamps ESL cannot be switched with dimmers without N-connection. Control voltage 230V. Minimum load 40W. Switch in zero passage with soft-on and soft-out for lamp protection. With %-Drehschalter the minimum brightness (fully dimmed) can be set. The dimming speed can be set with the dim speed rotary switch. At the same time, the duration of soft-on and soft-off is changed. Short control commands turn on/off, permanent control changes the brightness up to the maximum value. An interruption of the control changes the dimming direction. The set brightness level remains stored when switching off. In the event of a power failure, the switching position and the brightness stage are stored and is switched on when the supply voltage is returned. Automatic electronic overload protection and overtemperature shutdown. In the event that light switches cannot be replaced by light switches, a separate control system is
€51.16
Eltako EUD61NPL-230V Universal Dimming Switch
3-10 days
Universal dimming switch without N connection, Power MOSFET up to 200W. Stand-by-Lower only 0.5 W, with control inputs for light sensor and light switch, minimum brightness, mode of operation and dimming speed adjustable, in the event that light switch cannot be replaced by light sensor, a separate control input for light switch is present, with children's room circuit, and slumber circuit nominal voltage: 230 W Color: blue Operation type: rotary knob Halogen-free: Yes Load type: universal. Stand-by loss only 0.5 Watt. With control inputs for light sensor and light switch. Minimum brightness, operating mode and dimming speed adjustable. For installation. 45mm long, 45mm wide, 18mm deep. Universal dimming switch for R and C loads up to 200W, depending on the ventilation conditions. Dimmable ESL and 230V LED lamps in the operating mode phase section up to 200W or in the operating mode phase section up to 40W, depending on the ventilation conditions. In the case of dimmable 230V LED lamps, which also light slightly in the switched-off state, a basic load element GLE must be connected parallel to the lamp. L-loads (inductive loads, for example wound transformers) must not be connected. Switching in the zero passage with soft-on and soft-out for lamp protection. Control voltage, supply voltage and switching voltage 230W. Minimum load 4W. Short control commands turn on/off, permanent control changes brightness up to maximum value. An interruption of the control changes the dimming direction. Set
€52.72
Eltako EUD61NPN-230V Universal Dimming Switch
3-10 days
Universal Dimming Switch Mounting type: Unterputz Color: blue Operation type: Rotary knob Halogen-free: Yes Composition: other load type: universal Serial dimmer: No Adjunct input: No Luminous accumulator: Yes Applicable with button: Yes Applicable with motion detector: No Applicable with presence detector: No Applicable with timer matt/timer: No Applicable with radio button: No. Power MOSFET up to 400W. Automatic lamp detection. Stand-by loss only 0.1 Watt. Minimum brightness or dimming speed adjustable. With children's room and slumber circuit. For installation. 45mm long, 45mm wide, 18mm deep. Universal dimming switch for lamps up to 400W, depending on the ventilation conditions. Dimmable energy-saving lamps ESL and dimmable 230V LED lamps additionally depend on lamp electronics. Switching in the zero passage with soft-on and soft-out for lamp protection. Control voltage, supply voltage and switching voltage 230V. No minimum load required. Short control commands turn on/off, permanent control changes the brightness up to the maximum value. An interruption of the control changes the dimming direction. The set brightness level remains stored when switching off (memory). In the event of a power failure, the switching position and the brightness stage are stored and is switched on when the supply voltage is returned. Automatic electronic overload protection and overtemperature shutdown. With the upper %Lampe/dim-speed rotary switch can either set the dimming speed or the minimum brightness (fully dimmed). The dimming speed also changes the duration of soft-on and soft-off. During operation, the lower rotary switch determines whether automatic lamp detection is effective
€50.26
Eltako EUD61NPN-UC power surge switch UP
3-10 days
Universal power surge dimming switch for installation and AP mounting for 230V incandescent lamps and halogen lamps, for NV halogen lamps with inductive transformers and with electronic transformers up to 400W as well as for dimmable energy saving lamps in the setting ESL to 100W, with rotary switches the minimum brightness can be set, at the same time the duration of soft-on and soft-off switch is changed, children's room and slumber. Power MOSFET up to 400W. Automatic lamp detection. Stand-by loss only 0.1 Watt. Minimum brightness or dimming speed adjustable. With children's room and slumber circuit. For installation. 45mm long, 45mm wide, 18mm deep. Universal dimming switch for lamps up to 400W, depending on the ventilation conditions. Dimmable energy-saving lamps ESL and dimmable 230V LED lamps additionally depend on lamp electronics. Switching in the zero passage with soft-on and soft-out for lamp protection. Universal control voltage 8..230V UC, galvanically isolated from the supply and switching voltage 230V. No minimum load required. Short control commands turn on/off, permanent control changes the brightness up to the maximum value. An interruption of the control changes the dimming direction. The set brightness level remains stored when switching off (memory). In the event of a power failure, the switching position and the brightness stage are stored and is switched on when the supply voltage is returned. Automatic electronic overload protection and overtemperature shutdown. With the upper %Lampe/dim-speed rotary switch can either set the dimming speed or the minimum brightness (fully dimmed). The dimming speed also changes the duration of soft-on and soft-off. During operation, the lower rotary switch determines whether the automatic lamp recognition should work or special comfort positions: AUTO allows the dimming of all lamp types. EC1 is a comfort site
€49.77
Eltako EVA12-32A Energy consumption indicator
3-10 days
Energy consumption indicator for series installation The energy consumption indicator EVA12 measures the active energy like an alternating current meter on the basis of the current flowing between the input and the output and stores the consumption in non-volatile memories Eltako- AC counters of class B at MID (1%), the starting current is 20 mA. In this way, the energy consumption display precisely reproduces the measurement of the meter installed elsewhere in the building for electricity billing. The display is divided into 3 fields. Up to 24 hours, up to 31 days, up to 12 months and up to 24 years can be completed. The memory can be reset. Maximum current (value): 32 A Energy consumption display with display - smart metering for support rail. Stand-by loss only 0.5 Watt. The energy consumption indicator measures the active energy like an alternating current meter on the basis of the current flowing between the input and the output and stores the consumption in non-volatile memories. The accuracy corresponds to all Eltako- AC counters of class B at MID (1%), the starting current is 20mA. In this way, the energy consumption display precisely reproduces the measurement of the meter installed elsewhere in the building for electricity billing. The display is divided into 3 fields. Totalreset: In order to start storing the values in exact hours, a total set is recommended at a reasonable time after installation. To do this, hold the MODE and SELECT keys simultaneously for 5 seconds until RES appears in field 1. If SELECT is now briefly pressed, all memories are set to zero. After that, the program automatically returns to the normal display.
€53.12
Eltako FBA14 RS485 Bus Coupler
3-10 days
Bus couplers for wire connections of the bus and power supply bridges, for mounting on support rail DIN-EN 60715 TH35, cross wiring bus and power supply with plug-in bridge, can connect both different bus parts and feed in power supplies, bus parts on different support rails or in other distributors or switch cabinets are each connected with an FBA14 and a 4-wire shielded bus line, e.g. a telephone line. Bus and power supply with plug-in bridge. The bus coupler FBA14 can connect both different bus parts and feed power supplies. Bus parts on different support rails or in other distributors or control cabinets are each connected to an FBA14 and a 4-wire shielded bus line, for example a telephone line. The total length of all connecting lines should not exceed 100m and the only 9mm wide 2nd final resistance to the FAM14 or FTS14KS must be plugged onto the last actuator. The position of the bus coupler in a series of devices of the series 14 is arbitrary.