Eltako

Eltako ER12-200 UC switching relay
3-10 days
Switching relay for mounting on support rails DIN-EN60715 TH35 No heat losses due to internal bistable relay,DX=Eltako-Duplex technology, switch in the zero crossing of the sine wave of a 230V switching voltage, low switching noise, control indicator with light-emitting diode, integrated freewheel/lowering diode (A1 =+, A2 =−) TLE: 1 number of contacts as a closer: 2 measurement control supply voltage Us at AC 50 Hz: 8 - 230 V switching relays. No standby loss. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Very low switching noise. Control indicator with light-emitting diode. The connection terminal occupancy is identical to the electromechanical switching relay R12-200-. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. The relay contact can be open or closed during commissioning and synchronizes during the first actuation. This relay is not suitable for feedback with the switching voltage of a dimming switch. The electronics have no own power supply and therefore no stand-by loss. Only when the control contact is closed is the microcontroller which switches the bistable relay in the correct direction. When the control contact is opened or a falling control voltage is switched back.
€39.93
Eltako ER61 UC relay UP
3-10 days
Switching relays for installation and AP mounting potential-free 10A/250V AC, No stand-by loss Universal control voltage 8-230 W UC, bistable relay as working contact, very low switching noise, due to the use of a bistable relay, there is no coil loss power and no heating as a result of switching relay UC. 1 changer potential-free 10A/250V AC, light bulbs 2000W. No standby loss. For installation and AP mounting. 45 mm long, 45mm wide, 18mm deep. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Universal control voltage 8..230V UC. Very low switching noise. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. The relay contact can be open or closed during commissioning and synchronizes during the first actuation. This relay is not suitable for feedback with the switching voltage of a dimming switch. Use only the relays ESR12DDX-UC, ESR12NP-230V+UC or ESR61NP-230V+UC. The electronics have no own power supply and therefore no stand-by loss. Only when the control contact is closed is the microcontroller which switches the bistable relay in the correct direction. When the control contact is opened or a falling control voltage is switched back. Number of contacts as changer: 1 measurement control supply voltage Us at AC 50 Hz: 8 - 230 W
€37.97
Eltako ES12-110-8..230V UC power breaker
3-10 days
Power surge switches, electronic for mounting on support rail DIN-EN 60715 TH35 potential-free 16A/250V AC, incandescent lamps 200W No stand-by loss, maximum current as a sum of both contacts 20A at 230V, connection terminal occupancy is identical with current surge switches S12 width in division units: 1 Number of switches: 1 Number of openers: 1 Rated switch current: 16DC. Bulb load: 2000 W Max. Lamp load: 1000 VA Max. Fluorescent lamp load (Duo circuit): 1000 VA Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 4 A manual operation possible: No power surge switch UC. No standby loss. Either universal control voltage 8..230V UC at the control input +A1/-A2 or 230W with up to 5ma glow lamp current at the control input with glow lamp symbol (L)/-A2(N). The simultaneous use of two potentials at the tax inputs is not permissible. Very low switching noise. No constant power supply required, therefore no stand-by loss. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. The relay contact can be open or closed during commissioning and synchronizes during the first actuation. The connection terminal occupancy is identical to the electromechanical current surge switch .
€40.43
Eltako ES12-200-UC 8..230V UC power surge switch
3-10 days
Power surge switch, electronic for mounting on support rail DIN-EN 60715 TH35 potential-free 16A/250V AC, incandescent lamps 200W No stand-by loss, maximum current as the sum of both contacts 20A at 230V, connection terminal occupancy is identical with current surge switch S12 width in division units: 1 Number of switches: 2 Rated switch current: 16 A. Bulb load: 2000 W Max. Lamp load: 1000 VA Max. Fluorescent lamp load (Duo circuit): 1000 VA Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 4 A manual operation possible: No power surge switch UC. No standby loss. Either universal control voltage 8..230V UC at the control input +A1/-A2 or 230W with up to 5ma glow lamp current at the control input with glow lamp symbol (L)/-A2(N). The simultaneous use of two potentials at the tax inputs is not permissible. Very low switching noise. No constant power supply required, therefore no stand-by loss. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. The relay contact can be open or closed during commissioning and synchronizes during the first actuation. Maximum current as a sum of both contacts 16A at 230W.
€40.43
Eltako ES12DX-UC power surge switch
3-10 days
Current surge switches, electronic for mounting on support rail DIN-EN 60715 TH35 potential-free 16A/250V AC, incandescent lamps 200W No stand-by loss, maximum current as a sum over both contacts 20A at 230V, connection terminal occupancy is identical with current surge switches S12 current surge switches, stand-by consumption of only 0.1 Watt. If the contact is used for controlling switching devices which themselves do not switch in the zero passage, (N) should not be connected, since the additional closing delay otherwise causes the opposite. The simultaneous use of two potentials at the tax inputs is not permissible. Very low switching noise. No constant power supply required, therefore no stand-by loss. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. The relay contact can be open or closed during commissioning and synchronizes during the first actuation. The connection terminal occupancy is identical to the electromechanical current surge switch. Width in division units: 1 Number of locks: 1 Rated switching current: 16 A Control voltage type 1: AC/DC Installation depth: 58 mm Function: electronic switch Mounting type: DIN rail Frequency of control voltage 1: 50 - 50 Hz Voltage type of supply voltage: AC Supply voltage range: 250 - 250 W Max. Bulb load: 2000 W Max. Lamp load: 1000 VA Max. Fluorescent lamp load (Duo circuit): 1000 VA Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 4 A manual operation possible: No
€37.47
Eltako ES12Z-110-8..230V UC Current surge switch
3-10 days
Current surge switches, electronic for central control work contacts and control inputs are central/local are galvanically separated, therefore local can be controlled with another phase and voltage, as central, with rotary switches various priorities can be set between the different control inputs, in this case it is also decided whether the device switches off in a defined manner after a mains failure or maintains the switch position, Glimm lamp current equal to 110W control voltage. Stand-by loss only 0.03 to 0.4 Watt. Priorities of central control can be selected. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. With additional control inputs centrally and centrally separated from the local control input for 8.230V UC. Supply voltage like the local control voltage. Very low switching noise. Glow lamp current from 110W control voltage up to 50ma in switch positions 1 to 3 and 5 to 7. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Maximum current as a sum over both contacts 20A at 230W. With control LED. Width in division units: 1 Number of locks: 1 Number of openers: 1 Rated switching current: 16 A Installation depth: 58 mm Function: electronic for central control Assembly type: DIN rail Frequency of control voltage 1: 50 - 50 Hz Frequency of control voltage 2: 50 - 50 Hz Voltage type of supply voltage: AC Supply voltage range: 250 - 250 W Max. Bulb load: 2000 W Max. Lamp load: 1000 VA Max. Light
€48.79
Eltako ES12Z-200-8..230V UC power breaker
3-10 days
Current surge switches, electronic for central control work contacts and control inputs are central/local are galvanically separated, therefore local can be controlled with another phase and voltage, as central, with rotary switches various priorities can be set between the different control inputs, in this case it is also decided whether the device switches off in a defined manner after a mains failure or maintains the switch position, Glimm lamp current equal to 110W control voltage. Stand-by loss only 0.03 to 0.4 Watt. Priorities of central control can be selected. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. With additional control inputs centrally and centrally separated from the local control input for 8.230V UC. Supply voltage like the local control voltage. Very low switching noise. Glow lamp current from 110W control voltage up to 50ma in switch positions 1 to 3 and 5 to 7. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Maximum current as a sum of both contacts 16A at 230W. With control LED. This flashes after 15 seconds with blocked local probe, not in the rotary switch positions 4 and 8. With the upper rotary switch, this current surge switch can be completely or partially excluded from the central control. Width in division units: 1 Number of locks: 2 Rated switching current: 16 A Installation depth: 58 mm Function: electronic switch Assembly type: DIN rail Frequency of control voltage 1: 50 - 50 Hz Fre
€50.26
Eltako ES61-8..230V UC power surge switch UP
3-10 days
10A/250V AC, incandescent lamps 2000W, no stand-by loss, hybrid technology, either universal control voltage 8..230V UC at control input +A1/-A2 or 230 W with up to 5 ma Glow lamp current at control input (L)/-A2(N) current surge switches UC. 1 lock potential-free 10A/250V AC, light bulbs 2000W. No standby loss. For installation. 45mm long, 45mm wide, 18mm deep. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Either universal control voltage 8..230V UC at the control input +A1/-A2 or 230W with up to 5ma glow lamp current at the control input with glow lamp symbol (L)/-A2(N). The simultaneous use of two potentials at the tax inputs is not permissible. Very low switching noise. No constant power supply required, therefore no stand-by loss. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. The relay contact can be open or closed during commissioning and synchronizes during the first actuation. If this current surge switch is in a circuit which is monitored with a field-free switch FR12-230V, it does not require an additional base load, but the monitoring voltage of the FR12-230V must be set to max. The electronics have no own power supply and therefore no power consumption in both contact positions. Only during the short control pulse of only 0.2 seconds, the control current, which activates the microcontroller, lets it read the last switching state from its non-volatile memory, switches the bistable relay accordingly in the opposite direction and writes the new switching state back into the memory. Number of contacts as lock: 1 Rated control voltage Us at AC 60 Hz: 250 - W
€39.44
Eltako ES75-100-12..24V UC POWER SWITCH E
3-10 days
Electronic power surge switches for control voltages of 12-24 W AC and DC (UC), with interconnected transformer for galvanic separation between control and circuit. For bulbs up to 500 W and fluorescent lamps in DUO circuit up to 1000 W. Low switching noise. Electric shock switch for luminaire installation 12..24V UC. 1 lock not potential-free 10A/250V AC. Stand-by-loss only 1 watt. For installation mounting. 85mm long, 40mm wide, 28mm deep. With integrated transformer for galvanic isolation between control circuit and circuit to meet the requirements for low-voltage protection. Control voltage 12 to 24W UC, control current 10ma at 24W. Constant power supply 230W. For bulb and halogen lamp load (for lamps with max. 150W) up to 500W and fluorescent lamps with KWG in DUO circuit up to 1000VA. Fluorescent lamps with KWG parallel compensated 300VA. Temperature at the installation point between -20°C and +50°C. minimum duration/command pause 20/300ms. 4-pin pin housing for plug STOCKO MKF13264-6-0-404, 230V side 6-pin clamping bar with plug terminals, maximum conductor cross-section 2.5qmm. A Stocko plug is attached to any device. Number of locks: 1 Rated current: 10 A Control voltage 1: 12 - 24 W Control voltage type 1: AC/DC Installation depth: 28 mm Function: other assembly type: other voltage type of supply voltage: AC Supply voltage range: 250 - 250 W Max. Bulb load: 500 W Max. Lamp load (Duo circuit): 1000 VA
€37.47
Eltako ESR12DDX-UC Electronic power surge.
3-10 days
multifunction power surge relay for mounting on support rail DIN-EN 60715 TH35 1+1 closer, it can be selected between 18 different power surge switches or relay functions with which Eltako-Duplex technology (DX) can switch the potential-free contacts when switching 230V AC / 50Hz in the zero crossing of the sine wave, supply and control voltage 8..230V UC, rated switching power 16A/250V AC TLE: 1 number of locks: 2 number of openers: 2 width in division units: 1 Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Fluorescent lamp load (Duo circuit): 1000 VA Max. Incandescent lamp load: 2000 W supply voltage range: 8 - 230 V control voltage 1: 8 - 230 V control voltage type 1: AC/DC frequency of control voltage 1: 50 - 50 Hz Max. Lamp load: 1000 VA Max. Switching current (cos phi = 0.6): 4 A Installation depth: 58 mm Function: partially electronic digital adjustable multi-function current surge relays. Stand-by loss only 0.03 to 0.4 Watt. To this end, simply connect the N conductor to the terminal (N) and L to 1(L) and/or 3(L). This results in an additional stand-by loss of only 0.1 Watt. Universal control voltage 8..230V UC. Supply voltage like the control voltage. The functions are entered according to the user manual with the MODE and SET keys and displayed digitally on an LC display, optionally also locked. The run-on time is constantly displayed. Due to the use of bistable relays, there is no coil loss power and no heating thereby even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Only for the power surge switch functions: If the supply voltage fails, it is switched off in a defined manner depending on the setting or the switching position is maintained (then + in the display next to the function shortening).
€57.64
Eltako ESR12NP-230V+UC Electric shock relay
3-10 days
Current surge relays for mounting on support rails DIN-EN 60715 TH35 16A/250V AC not potential-free, control input 230W AC and additional universal control voltage 8 to 230W UC, with rotary switches for the functions ER = switching relays, ES = current surge switches and ESW = current surge switches with reverse deceleration of 2 to 120 minutes plus switchable switch-off warning and push-off light. Relapse delay with switch-off warning and push-button continuous light can be switched on. Stand-by loss only 0.5 Watt. Contact circuit in the zero passage for protecting the contacts and lamps, in particular this extends the service life of energy-saving lamps. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Control voltage additionally with galvanically separated universal control voltage. Very low switching noise. Precise time setting of the relapse delay RV in the function ESW from 2 to 120 minutes with minute scale. With control LED. This flashes after 15 minutes with blocked probe (not in function ER). At the 230V control input Glow lamp current up to 150ma, regardless of the ignition voltage (not in function ER). In the relay functions suitable for feedback with the switching voltage of a dimming switch. If the supply voltage fails, it is switched off in a defined manner. The current surge switch automatically switches off after the set delay time has expired if the manual out command has not been given. Time range up to 120 minutes adjustable.
€39.93
Eltako ESR61NP 230V+UC power surge relays UP
3-10 days
Current surge switches for installation and AP mounting control input 230W AC and additional universal control voltage 8 to 230W UC, with a rotary switch for the functions ER = switching relays, ES = current surge switches and ESW = current surge switches with reverse deceleration number of contacts as closers: 1 measurement control voltage Us at AC 50 Hz: 8 - 230W current surge relay 230V+UC. 1 Locker not potential-free 10A/250V AC, incandescent lamps 2000W, fallback delay with switch-off warning and pushbutton continuous light can be switched on. Stand-by loss only 0.7 Watt. For installation. 45mm long, 45mm wide, 18mm deep. Contact circuit in the zero passage for protecting the contacts and lamps, in particular this extends the service life of energy-saving lamps. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Control voltage 230W, in addition with galvanically separated universal control voltage 8..230V UC. Supply and switching voltage 230W. Very low switching noise. Time setting up to 120 minutes in the function ESW. Sensors with a glow lamp current up to 50ma can be connected to the control input with a glow lamp symbol. If the supply voltage fails, it is switched off in a defined manner. If the delay time is set to a minimum in the ESW function, the relapse delay is switched off and the normal current surge switch function ES results. Switchable to the switching relay ER function. In the function ER, no glow lamp current is permissible and should only be used the control input A1-A2. In the function ER also suitable for feedback with the switching voltage of a dimming switch. When switched on
€39.93