Best sellers

Dehn 390050 MV CLEMME 8-10
2-7 days
for universal use as cross, T and parallel clamps, two-piece, thread in the bottom part with hexagonal screw M10 DIN 933
€1.76
Legrand 664731 Niloe socket SL without expansion claws ultrawhite
2-8 days
Legrand 664731 Niloe socket SL without expansion claws ultrawhiteInserts are supplied including rocker / cover and protective cover. Fastening by screws or spreader claws - inserts for screw fastening can be used with spreader claws. 6650 99. Connection by plug (SL) or screw terminals (SK).
€4.25
ABB 2CDS251001R0134 S201-C13 automatic fuse C-Char., 6 kA, 13 A, 1P
2-7 days
The automatic safety devices of the S 200 series protect cables and cables from overload and short circuit according to DIN VDE 0100-430 and DIN VDE 0100-530. They meet the construction requirements DIN VDE 0641-11 and IEC/EN 60898-1, DIN VDE 0660-101 and IEC/EN60947-2 and UL1077. Their patented connection terminal ensures easy and secure contacting and handling by means of a printing plate. For better visibility conditions during wiring, the connection opening for lines lies above the connection opening for the phase rail. Conductor cross sections up to 35 mm2 can be connected directly to the device via the connection terminal with insulation in protection class IP20. The extensive range of accessories offers you everything you need for your installation tasks. Numerous authorisations make the S 200 fit for worldwide use. Each device is subjected to three-fold intensive tests on quality and performance before delivery.
€8.49
Eaton Z-SLS/CEK35/3 Neozed Lasttrennschalter D02/D01 35A 3Polig kodiert 4,5TE 248245
2-5 days
Stromkodierung durch Sicherungsset plombierbar Einspeisung beidseitig möglich Komplett mit unverlierbarer Stromkodierung Standard, leer




Bemessungsbetriebsspannung

 
 
60 - 400 V AC



Pole

 
 
3



Bemessungsdauerstrom Iu bei max. Querschnitt

Iu
A
35



Sicherungseinsatz

 
Baugröße
D02: 25 - 63 AD01: 10 - 16 A




Technische Daten



Elektrisch



Polzahl

 
 
1P1P+N3P3P+N



Bemessungsbetriebsspannung

Ue
V
 



Bemessungsbetriebsspannung

Ue
V AC
400



Bemessungsdauerstrom

Iu
A
1P, 1P+N 10, 16, 25 A3P, 3P+N 16, 25, 35, 50, 63 A



Bemessungskurzschlusseinschaltvermögen

Icm
 
50 kAeff



Schaltkategorie

 
 
A 22 B



Überspannungskategorie

 
 
IV



Bemessungsstoßspannungsfestigkeit

Uimp
kV
6



Stromwärmeverlust pro Strombahn bei Ie

 
W
0.5



Verlustleistung

 
 
 



Verlustleistung pro Strombahn mit Sicherungseinsatz bei Ie

 
W
7.5


Mechanisch



Kappen-Einbaumaß

 
mm
45



Gehäusesockelmaß

 
mm
86



Einbaubreite

 
mm
27/Pol (1.5 TE)



Gewicht

 
g
147441



Montage

 
 
Schnellbefestigung für Hutschiene IEC/EN 60715



Schutzart

 
 
IP20



Klemmen

 
 
Liftklemmen



Anschlussquerschnitte

 
mm²
 



eindrähtig

 
mm2
1.5 - 35



Temperaturbereich

 
°C
-25 … +60



Brandklasse nach UL94

 
 
V0, Glühdrahtprüfung 960 °C



Anzugsdrehmoment Anschlussschrauben

 
Nm
max. 4.5


€59.95
Kaiser 1555-21 Branch switch socket ECON 15 without screw
2-5 days
airtight design with sealing membranes4 screw domes, 2 spreader claw fieldsDimensions according to DIN 49073for tubes M20/M25depth: 66 mmInstallation opening: 60 mmtoolless line and tube guides in the connecting region up to M25: 2 toolless line and pipe guides up to 11 mm below the neck: 2 toolless line and pipe feeders up to M25 at the container circumference: 4 toolless line and tube guides up to 11 mm at the circumference of the can: 4
€1.91
Dietzel FXP-Turbo Schlauch 40 GR 25M Panzerflex Rohr grau
1-5 Tage
Flexible corrugated PVC tank pipe for medium mechanical stress. Use: as impact-resistant universal protective tube for installation and laying in hollow walls and concrete ceilings Color: Grey (RAL 7037) Pressure strength: >750 N Marking: EN 3341 Application: -25° C to +60° C
€39.50
On sale!
PROTEC.class PHLAK2522BL main line branch terminal
2-7 days
Main line branch terminals 25/16 mm2, 1-pole. Classy. Mounting on 35 mm support rail according to. EN 50022 / EN 60715. e.g. for installation small distributors and counter positions according to. VDE 0603. Installation small distributor and counter positions AC 400V. Main line branch terminals VDE 0603-2, connection material for low voltage circuits for household and similar purposes VDE 0613, Part 1 / EN 60998-1. Color coding corresponding to valid vein colors. Mounting horizontally or vertically. Voltage: 1000 VDE certified. Suitable for Cu and Al conductors. Inputs max. 25 mm2: 2nd outputs max. 16 mm2: 2nd clamping body: brass, (galvanized). Clamp screws: steel, galvanized. Insulation housing: plastic, (polyamide) impact-resistant, halogen-free. Main line 1.5 - 25 mm2 rigid/several, 2.5 Nm. branch line: 1.5 - 16 mm2 rigid/multiplier, 2 Nm. Stripping length 16 mm. Bushing clamp with 2 screws per clamping point screws with combination slot Pozidriv Z2. IP 20, fingerproof. Corners rounded. Number of poles: 1 Colour: blue
€3.67
Eaton PLHT-C32-V LS switch 32A/1pol/C 25KA, V-special type 248104
2-5 days
Circuit breaker, 1-pole, rated current 32A, tripping characteristic C, rated operating voltage 230/400V, rated switching capacity according to IEC/EN 60947-2: 25kA, cap mounting dimension 45mm, installation width 1.5TE (27mm), hat rail mounting, clamping cross section 2.5-50 sqm
€37.39