Best sellers

Hager ACS916D FI/LS 1P+N 6kA B-Characteristic 16A 10mA Type A QC
2-5 days
1P+N 6kA B-Characteristic 16A 10mA type A QC fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 10 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V



Rated current
16 A


Trigger characteristic
B


Rated value
6


Type of differential protection
A


Sensitivity
10 mA


Number
2 P


Number of modules
2


Rated operating voltage Ue
240 V


Insulation voltage
500 V


Impact strength
4,000 V


Frequency
50 Hz


Torque
2.1Nm


Device life, electrical switching games
2000


Machine life mechanical switching games
2000


Connection cross section with flexible conductor
1 - 16mm2


Connection cross section for rigid conductor
1 - 25mm2


Operating temperature
-25 to 40 °C


Storage temperature
-25 to 70 °C


Height installed product
94 mm


Wide installed product
35 mm


Deep Installed Product
68 mm


€66.00
Hager CDS463D fault current switch 4 polig 6kA 63A 30mA Type A QuickConnect
3-7 working days
4 polig 6kA 63A 30mA Type A QuickConnect fault current protection switch according to EN 61008-1, DIN EN 61008-2-1 and VDE 0664 Part 10 + 11. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11 at access up to 63 A, IP2x touch protection according to DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Suitable for subsequent installation of additional equipment. Nominal current: 63 A Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Impact current strength (impulsive fault currents 8/20μs): 0.25 kA Number of modules: 4 Frequency: 50 Hz



Rated current
63 A


Type of differential protection
A


Sensitivity
30 mA


Number
4 P


Impact current resistance (pulse fault currents 8/20μs)
0,25


Number of modules
4


Frequency
50 Hz


Assembly type
DIN rail


Connection type
Screw technology


Connection cross section with flexible conductor
16mm2


Connection cross section for rigid conductor
25mm2


Torque
2.8 Nm


Type of protection
IP20


Insulation voltage
500 V


Impact strength
4 kV


Additional equipment possible
1


Operating temperature
-25 to 40 °C


Machine life mechanical switching games
4000


Device life, electrical switching games
2000


Total loss power at rated current
18.5 W


Degree of contamination according to IEC 60664 / IEC 60947-2
2


Height above N.N.
2000 m


Rated current at 30° C
63 A


Storage temperature
-55 to 70 °C


Height installed product
83 mm


Wide installed product
70 mm


Deep Installed Product
70 mm


€150.54
Hager CDS425D fault current switch 4 polig 6kA 25A 30mA Type A QuickConnect
3-7 working days
EN 61008-1, DIN EN 61008-2-1 and VDE 0664 Part 10 + 11. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11 at access up to 63 A, IP2x touch protection according to DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Suitable for subsequent installation of additional equipment. Nominal current: 25 A Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Impact current strength (impulsive fault currents 8/20μs): 0.25 kA Number of modules: 4 Frequency: 50 Hz Rated current25 AType of differential protectionASensitivity30 mANumber4 PImpact current resistance (pulse fault currents 8/20μs)0,25Number of modules4Frequency50 HzAssembly typeDIN railConnection typeQuickConnectConnection cross section with flexible conductor16mm2Connection cross section for rigid conductor25mm2Torque2.8 NmType of protectionIP20Insulation voltage500 VImpact strength4 kVAdditional equipment possible1Operating temperature-25 to 40 °CMachine life mechanical switching games4000Device life, electrical switching games2000Total loss power at rated current4.5 WDegree of contamination according to IEC 60664 / IEC 60947-22Height above N.N.2000 mRated current at 30° C25 AStorage temperature-55 to 70 °CHeight installed product83 mmWide installed product70 mmDeep Installed Product70 mm
€85.72
Hager KJ10S counter clamp AC 63 A, lockable, with TRE terminal
2-8 days
AC 63 A, lockable, with TRE terminal. Counter clamp according to DIN VDE 0603-3, Suitable for electricity meters according to DIN 43857,for the fast and safe change of electricity meters, nominal current: 63A, 1-pole, With 2. Connection for N conductor, 1 control line terminal per phase, terminal cross section main line up to 25mm2, terminal cross section control line up to 6mm2, color: RAL 9010, dimensions (LxBxH)= 90x40x32
€43.61