Best sellers

Berker 16216089 rocker m 2 lenses Q1/Q3 polar white
2-7 days
Rocker with 2 adjacent lenses Q.1/Q.3 polar white, velvet. rocker with 2 attached lenses (orange and clear.) For Wipp switches and Wipptast switches Off/exchange/cross, Wipptaster, Taster-BA 1-speed and Grouptaster-BA 1-speed. For lighting and control circuit. Underput installation, area program. Material: plastic, thermoset, halogen-free. rocker with 2 attached lenses (orange and clear.) For Wipp switches and Wipptast switches Off/exchange/cross, Wipptaster, Taster-BA 1-speed and Grouptaster-BA 1-speed. For lighting and control circuit. Underput installation, area program. Material: plastic, thermoset, halogen-free.
€6.50
Triax 4-Loch-Antennen-Steckdose GAD 274 - 23274
2-5 Tage
GAD274
GAD 274 4-Loch Dose ist für den Einsatz in Netzen mit DVB-T-, UKW- und DVB-S (S2)-Übertragung über zwei getrennte Stichleitungen vom Sat-Multischalter oder LNB mit zusätzlichem zweiten SATAnschluss für den gleichzeitigen Betrieb von zwei Sat-Receivern (z.B. Twin-Sat-Receiver.) bestimmt. Ohne die Aufputzrahmen kann die Dose auch als Unterputzdose montiert werden.
€13.78
Eaton TLK 101066 Stair time switch Comfort, 6 functions, 1S
2-8 days
Automatic stairlight electronically, turn off, switch off, switch off, long-term function programmable, energy saving function, low switching noise, automatic 3-/4-wire detection, zero voltage safety by memory function, central control function, external voltage control input
€60.21
Hager ADZ366D FI/LS 3X 1P+N 6kA C character. 16A 30mA Type A QC
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with 3 x 1-pole circuit breaker for 230 V AC circuits and a fault current protection circuit in the compact housing. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 16 A and at the access up to 63 A, contact protection according to IP2x DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: C Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Number of modules: 4 Rated operating voltage Ue: 230 VRated current16 ATrigger characteristicCRated value6Type of differential protectionASensitivity30 mANumber4 PNumber of modules4Rated operating voltage Ue230 VInsulation voltage500 VFrequency50 HzTorque2NmTotal loss power at rated current10.9 WDevice life, electrical switching games2000Machine life mechanical switching games2000Operating temperature-5 to 40 °CStorage temperature-55 to 70 °CHeight installed product86 mmWide installed product71 mmDeep Installed Product70 mm
€130.72
Hager ADS916D FI/LS 1P+N 6kA B-Characteristic 16A 30mA
3-8 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V



Rated current
16 A


Trigger characteristic
B


Rated value
6


Type of differential protection
A


Sensitivity
30 mA


Number
2 P


Number of modules
2


Rated operating voltage Ue
240 V


Insulation voltage
500 V


Impact strength
4,000 V


Frequency
50 Hz


Torque
2.1Nm


Total loss power at rated current
5.2 W


Device life, electrical switching games
2000


Machine life mechanical switching games
2000


Connection cross section with flexible conductor
1 - 16mm2


Connection cross section for rigid conductor
1 - 25mm2


Operating temperature
-25 to 40 °C


Storage temperature
-25 to 70 °C


Height installed product
94 mm


Wide installed product
35 mm


Deep Installed Product
68 mm


€48.96
Hager ADS913D FI/LS 1P+N 6kA B-Characteristic 13A 30mA
2-5 days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 13 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V



Rated current
13 A


Trigger characteristic
B


Rated value
6


Type of differential protection
A


Sensitivity
30 mA


Number
2 P


Number of modules
2


Rated operating voltage Ue
240 V


Insulation voltage
500 V


Impact strength
4,000 V


Frequency
50 Hz


Torque
2.1Nm


Total loss power at rated current
3.8 W


Device life, electrical switching games
2000


Machine life mechanical switching games
2000


Connection cross section with flexible conductor
1 - 16mm2


Connection cross section for rigid conductor
1 - 25mm2


Operating temperature
-25 to 40 °C


Storage temperature
-25 to 70 °C


Height installed product
94 mm


Wide installed product
35 mm


Deep Installed Product
68 mm


€73.20
Eaton PLHT-C50-V LS switch 50A/1pol/C 25KA, V-special type 248106
2-7 Tage
Circuit breaker, 1-pole, rated current 50A, tripping characteristic C, rated operating voltage 230/400V, rated switching capacity according to IEC/EN 60947-2: 25kA, cap mounting dimension 45mm, installation width 1.5TE (27mm), hat rail mounting, clamping cross section 2.5-50 sqm
€90.04