Eltako

Eltako R12-110-24VDC INSTALLATION RELAY
Eltako R12-110-24VDC INSTALLATION RELAY
3-10 days
Switching relay for mounting on support rails DIN-EN 60715 TH35 rated switching power 16 A/250 W AC or. 10 A/400 W AC Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W. Number of contacts as locks: 1 Number of contacts as openers: 1 TLE: 1 Rated control supply voltage Us at AC 50 Hz: 24 - W Voltage type for actuation: DC
€32.35
Eltako R12-110-12VDC INSTALLATION RELAY
Eltako R12-110-12VDC INSTALLATION RELAY
3-10 days
Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W. Mounting type: DIN rail Measurement current: 16 A Number of lockers: 1 Number of changers: 0 Number of openers: 1 Width in division units: 1 Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Fluorescent lamp load (Duo circuit): 2300 VA Max. Incandescent lamp load: 2300 W supply voltage range: 230 - 230 W control voltage 1: 12 - 12 W control voltage type 1: DC frequency of control voltage 1: 50 - 50 Hz Max. Fluorescent lamp load: 2300 VA voltage type of supply voltage: DC Max. Switching current (cos phi = 0.6): 10 A Installation depth: 55 mm Function: other
€32.35
Eltako IFES12-20TS/401204R0 REMOTE SWITCH 10A 12
Eltako IFES12-20TS/401204R0 REMOTE SWITCH 10A 12
3-10 days
Serial voltage 12W AC, current consumption 5ma, nominal current/voltage 10A/250V AC, switching sequence 0/1/2/1+2/0, no annoying switching noises, for DIN rails and screw fastening, 100% switch-on time, increased insensitivity to insecure contact of the probe, minimum power consumption, according to DIN WDE 0637 and EMV directive, contact-protected width. Bulb load: 2000 W Max. Fluorescent lamp load (Duo circuit): 1000 VA Max. Luminous lamp load (parallel compensated): 400 VA manual operation possible: No series switch. Electricity consumption 5ma. Sensor type: not illuminated. Serial switch, switching sequence 0/1/2/1+2/0. No troublesome switching noises. 100% switch-on time. Increased insensitivity to insecure contact of the probe. Minimum power consumption. In accordance with DIN WDE 0637 and EMC Directive. Protected against touch.
€33.44
Eltako KR09-230VAC COUPLED RELAY
Eltako KR09-230VAC COUPLED RELAY
3-10 days
Coupling relay width 9 mm for support rails DIN EN 60715 TH35, switching position indicator with LED. Only 1/2 division unit = 9 mm wide, 55 mm deep. Safe separation according to WDE 0106, part 101 Voltage type for actuation: AC Number of contacts as closer: 1 Rated control voltage Us at AC 50 Hz: 230 - W Coupling relays. No standby loss. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Control indicator with LED. Only 0.2W. Safe separation according to WDE 0106, part 101, therefore also usable as a coupling relay.
€33.99
Eltako KR09-24VUC
Eltako KR09-24VUC
3-10 days
Coupling relay width 9 mm for support rails DIN EN 60715 TH35, switching position indicator with LED. Only 1/2 division unit = 9 mm wide, 55 mm deep. Safe separation according to WDE 0106, part 101 Mounting type: DIN rail Measurement current: 6 A Number of locks: 1 Number of changers: 0 Number of openers: 0 Width in division units: 0.5 Max. Fluorescent lamp load (parallel compensated): 300 VA Max. Luminous lamp load (Duo circuit): 600 VA Max. Incandescent lamp load: 500 W supply voltage range: 250 - 250 W control voltage 1: 24 - 24 W control voltage type 1: AC/DC frequency of control voltage 1: 50 - 50 Hz Max. Luminous lamp load: 600 VA voltage type of supply voltage: AC Max. Switching current (cos phi = 0.6): 2 A Installation depth: 55 mm Function: partially electronic coupling relays. No standby loss. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Control indicator with LED. Only 0.2W. Safe separation according to WDE 0106, part 101, therefore also usable as a coupling relay.
€33.99
Eltako ETR61NP-230V separation relay
Eltako ETR61NP-230V separation relay
3-10 days
Frequency range: 50 - 50 Hz Nominal voltage: 230 W Mounting type: other central input: Yes No Number of connectable motors: 1 Switching current: 10 A separator relay 230W. 1 lock not potential-free 10A/250V AC. Stand-by loss only 0.5 Watt. For installation. 45mm long, 45mm wide, 18mm deep. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Control input with internally generated low voltage 24W DC. galvanically separated from the power supply and the working contact (PELV). Therefore, no external low-voltage power supply is required. With two L-terminals and 2 N-terminals for easy and fast installation. Power supply 230W.
€34.98
Eltako TLZ12-8 Staircase Time Clock
Eltako TLZ12-8 Staircase Time Clock
3-10 days
Rated voltage: 50 %. Bulb load: 2000 W Max. Lamp load: 1000 VA Max. Fluorescent lamp load (Duo circuit): 1000 VA Max. Fluorescent lamp load (parallel compensated): 500 VA stairlight time switch, without switch-off warning. Stand-by-loss only 0.7 Watt. Time setting about 0.2 to 12 minutes. Own continuous light switch with the large rotary switch. For 3- and 4-wire circuits, switchable, with attic lighting at 4-wire circuit. Automatic detection of the circuit type. Without disconnection and contact circuit in the zero passage. With double connections for probe and lamp, so that it can be connected either at the top and bottom or only at the bottom.
€35.63
Eltako P3K12-230V PHASENKONTROL
Eltako P3K12-230V PHASENKONTROL
3-10 days
Design of the electrical connection screw connection, measurement control supply voltage Us at AC 50 Hz 230 ... 400V, measurement control supply voltage Us at AC 60 Hz 230 ... 400V, voltage type for actuation AC, function phase failure detection, width 17.5mm, for optical monitoring of 1 to 3 phases 230 V. Display by three red light-emitting diodes for 230 V AC. Number of contacts as locks: 0 Number of contacts as openers: 0 Type of electrical connection: Screw connection Type of voltage for actuation: AC Number of contacts as changer: 0 Width: 18 mm Height: 58 mm Depth: 58 mm Function Overvoltage detection: No Rated control voltage Us at AC 50 Hz: 230 - 230 V With removable clamps: No Function Phase sequence detection: No Function. Series installation unit with 1 division unit. For optical monitoring of 1 to 3 external conductors 230V. Display with three red light-emitting diodes.
€40.99
Eltako ES12DX-UC power surge switch
Eltako ES12DX-UC power surge switch
3-10 days
Current surge switches, electronic for mounting on support rail DIN-EN 60715 TH35 potential-free 16A/250V AC, incandescent lamps 200W No stand-by loss, maximum current as a sum over both contacts 20A at 230V, connection terminal occupancy is identical with current surge switches S12 current surge switches, stand-by consumption of only 0.1 Watt. If the contact is used for controlling switching devices which themselves do not switch in the zero passage, (N) should not be connected, since the additional closing delay otherwise causes the opposite. The simultaneous use of two potentials at the tax inputs is not permissible. Very low switching noise. No constant power supply required, therefore no stand-by loss. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. The relay contact can be open or closed during commissioning and synchronizes during the first actuation. The connection terminal occupancy is identical to the electromechanical current surge switch. Width in division units: 1 Number of locks: 1 Rated switching current: 16 A Control voltage type 1: AC/DC Installation depth: 58 mm Function: electronic switch Mounting type: DIN rail Frequency of control voltage 1: 50 - 50 Hz Voltage type of supply voltage: AC Supply voltage range: 250 - 250 W Max. Bulb load: 2000 W Max. Lamp load: 1000 VA Max. Fluorescent lamp load (Duo circuit): 1000 VA Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 4 A manual operation possible: No
€41.63
Eltako ES75-100-12..24V UC POWER SWITCH E
Eltako ES75-100-12..24V UC POWER SWITCH E
3-10 days
Electronic power surge switches for control voltages of 12-24 W AC and DC (UC), with interconnected transformer for galvanic separation between control and circuit. For bulbs up to 500 W and fluorescent lamps in DUO circuit up to 1000 W. Low switching noise. Electric shock switch for luminaire installation 12..24V UC. 1 lock not potential-free 10A/250V AC. Stand-by-loss only 1 watt. For installation mounting. 85mm long, 40mm wide, 28mm deep. With integrated transformer for galvanic isolation between control circuit and circuit to meet the requirements for low-voltage protection. Control voltage 12 to 24W UC, control current 10ma at 24W. Constant power supply 230W. For bulb and halogen lamp load (for lamps with max. 150W) up to 500W and fluorescent lamps with KWG in DUO circuit up to 1000VA. Fluorescent lamps with KWG parallel compensated 300VA. Temperature at the installation point between -20°C and +50°C. minimum duration/command pause 20/300ms. 4-pin pin housing for plug STOCKO MKF13264-6-0-404, 230V side 6-pin clamping bar with plug terminals, maximum conductor cross-section 2.5qmm. A Stocko plug is attached to any device. Number of locks: 1 Rated current: 10 A Control voltage 1: 12 - 24 W Control voltage type 1: AC/DC Installation depth: 28 mm Function: other assembly type: other voltage type of supply voltage: AC Supply voltage range: 250 - 250 W Max. Bulb load: 500 W Max. Lamp load (Duo circuit): 1000 VA
€41.63
Eltako ER12 DX-UC Universalsp. Relay
Eltako ER12 DX-UC Universalsp. Relay
3-10 days
Switching relay for mounting on support rails DIN-EN60715 TH35 No heat losses due to internal bistable relay,DX=Eltako-Duplex technology, switch in the zero crossing of the sine wave of a 230V switching voltage, low switching noise, control indicator with light-emitting diode, integrated freewheel/lowering diode (A1 =+, A2 =−) switching relays. No standby loss. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. To this end, simply connect the N conductor to the terminal (N) and L to 1 (L). This results in a stand-by consumption of only 0.1 Watt. If the contact is used for controlling switching devices which themselves do not switch in the zero passage, (N) should not be connected, since the additional closing delay otherwise causes the opposite. Very low switching noise. Control indicator with light-emitting diode. The connection terminal occupancy is identical to the electromechanical switching relay R12-100-. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. The relay contact can be open or closed during commissioning and synchronizes during the first actuation. This relay is not suitable for feedback with the switching voltage of a dimming switch. The electronics have no own power supply and therefore no stand-by loss. Only when the control contact is closed is the microcontroller which switches the bistable relay in the correct direction. When the control contact is opened or a falling control voltage is switched back. TLE: 1 Number of contacts as closer: 1 Rated control voltage Us at AC 50 Hz: 8 - 230 V
€41.63
Eltako NLZ61NP-230V Restart switch 1 S
Eltako NLZ61NP-230V Restart switch 1 S
3-10 days
After running switch for installation not potential-free 10A/250V AC, stand-by-loss only 0.7 Watt, contact circuit in the zero passage for the protection of the contacts and consumers, state-of-the-art hybrid technology combines the advantages of wear-free electronic control with the high power of special relays, control voltage, supply and switching voltage 230W, follow-up time 1 to 12 minutes, response delay 0 to 12 minutes control voltage 1: 230 - 230 W. Time range from/to: 0 - 12 2. Time range from/to: 12 - 1 function: response and fall delay Number of locks: 1 switching power bulbs: 2000 W supply voltage range: 250 - 250 W installation height: 18 mm rated current at 250 W AC: 10 A switching power fluorescent lamps DUO: 1000 VA 1. Time range unit: minutes/hours 2. Time range unit: seconds/minutes assembly type: Unterputz follow-up switch 230W. 1 lock not potential-free 10A/250V AC. Stand-by-loss only 0.7 Watt. For installation. 45mm long, 45mm wide, 18mm deep. Contact circuit in the zero passage to protect the contacts and consumers. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Control voltage, supply and switching voltage 230W. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Adjustable with the upper rotary switch for 1 to 12 minutes. Response delay 0 to 12 minutes with the lower rotary switch adjustable. Function: With the closing of the control contact (light switch), the response delay AV (if not set 0) begins, at whose end the fan is switched on wi
€42.19
Eltako ER61 UC relay UP
Eltako ER61 UC relay UP
3-10 days
Switching relays for installation and AP mounting potential-free 10A/250V AC, No stand-by loss Universal control voltage 8-230 W UC, bistable relay as working contact, very low switching noise, due to the use of a bistable relay, there is no coil loss power and no heating as a result of switching relay UC. 1 changer potential-free 10A/250V AC, light bulbs 2000W. No standby loss. For installation and AP mounting. 45 mm long, 45mm wide, 18mm deep. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Universal control voltage 8..230V UC. Very low switching noise. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. The relay contact can be open or closed during commissioning and synchronizes during the first actuation. This relay is not suitable for feedback with the switching voltage of a dimming switch. Use only the relays ESR12DDX-UC, ESR12NP-230V+UC or ESR61NP-230V+UC. The electronics have no own power supply and therefore no stand-by loss. Only when the control contact is closed is the microcontroller which switches the bistable relay in the correct direction. When the control contact is opened or a falling control voltage is switched back. Number of contacts as changer: 1 measurement control supply voltage Us at AC 50 Hz: 8 - 230 W
€42.19
Eltako TLZ61NP-230V Stair Time Switch
Eltako TLZ61NP-230V Stair Time Switch
3-10 days
Steplight time switch, electronic for installation and AP installation, 10A/250V AC, control voltage 230W AC, Glow lamp current 50ma, with pumps, switch-off warning and pushbutton continuous light, in addition the function: current surge switch with drop-back delay ESW, contact circuit in the zero crossing of the sine wave to the device and lamp-saving stairlight time switch 230W. 1 lock not potential-free 10A/250V AC, incandescent lamps up to 2000W, ESL and LED lamps up to 200W, switch-off warning and push-button continuous light. Stand-by-loss only 0.7 Watt. With ESL optimization.For installation. 45mm long, 45mm wide, 18mm deep. Contact circuit in the zero passage for protecting the contacts and lamps. In particular, this extends the service life of energy-saving lamps. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Control, supply and switching voltage 230W. Time setting 1 to 12 minutes. Glow lamp current up to 50ma, depending on the ignition voltage of the glow lamps. For 3- and 4-wire circuits, switchable, with attic lighting at 4-wire circuit. Automatic detection of the circuit type. After a power failure, the illumination is switched on again when the time sequence has not yet been completed. When switched off, the lighting flickers approx. 30 seconds before the time sequence beginning and a total of 3 times in shorter time intervals. When the pushbutton permanent light is switched on, it is possible to set for longer than 1 second by means of buttons, which is switched off automatically after 60 minutes or can be switched off with buttons for longer than 2 seconds. If the pushbutton continuous light and the switch-off pre-warning are switched on, the switch-off pre-warning takes place after the switch-off of the continuous light. Become a full or part
€42.73
Eltako ER12-001-8..230V UC relay
Eltako ER12-001-8..230V UC relay
3-10 days
Control relays for support rails DIN EN 60715 TH35 switching position indicator by light-emitting diode, low control power requirement, low switching noise, for small currents, low self-heating, with integrated free-wheeling/lowering diode (A1=+, A2=′′), ER12-001-12 ̊230 W UC according to WDE 010, part 101, therefore also used as coupling relay A250. No standby loss. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Low switching noise. Control indicator with light-emitting diode. Integrated freewheel/leak diode (A1 =+, A2 =−). Safe separation according to WDE 0106, part 101, therefore also usable as a coupling relay. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. The relay contact can be open or closed during commissioning and synchronizes during the first actuation. This relay is not suitable for feedback with the switching voltage of a dimming switch. The electronics have no own power supply and therefore no stand-by loss. Only when the control contact is closed is the microcontroller which switches the bistable relay in the correct direction. When the control contact is opened or a falling control voltage is switched back. TLE: 1 Number of contacts as changer: 1 Rated control voltage Us at AC 50 Hz: 230 - 230 W
€43.28