Hager ADZ316D FI/LS 3X 1P+N 6kA B character. 16A 30mA Type A QC
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with 3 x 1-pole circuit breaker for 230 V AC circuits and a fault current protection circuit in the compact housing. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 16 A and at the access up to 63 A, contact protection according to IP2x DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Number of modules: 4 Rated operating voltage Ue: 230 V



Rated current
16 A


Trigger characteristic
B


Rated value
6


Type of differential protection
A


Sensitivity
30 mA


Number
4 P


Number of modules
4


Rated operating voltage Ue
230 V


Insulation voltage
500 V


Frequency
50 Hz


Torque
2Nm


Total loss power at rated current
10.9 W


Device life, electrical switching games
2000


Machine life mechanical switching games
2000


Operating temperature
-5 to 40 °C


Storage temperature
-55 to 70 °C


Height installed product
86 mm


Wide installed product
71 mm


Deep Installed Product
70 mm


€81.82
Hager ADZ363D FI/LS 3X 1P+N 6kA C character. 13A 30mA Type A QC
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with 3 x 1-pole circuit breaker for 230 V AC circuits and a fault current protection circuit in the compact housing. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 16 A and at the access up to 63 A, contact protection according to IP2x DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 13 A Trigger characteristic: C Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Number of modules: 4 Rated operating voltage Ue: 230 V



Rated current
13 A


Trigger characteristic
C


Rated value
6


Type of differential protection
A


Sensitivity
30 mA


Number
4 P


Number of modules
4


Rated operating voltage Ue
230 V


Insulation voltage
500 V


Frequency
50 Hz


Torque
2Nm


Total loss power at rated current
9.6 W


Device life, electrical switching games
2000


Machine life mechanical switching games
2000


Operating temperature
-5 to 40 °C


Storage temperature
-55 to 70 °C


Height installed product
86 mm


Wide installed product
71 mm


Deep Installed Product
70 mm


€111.30
Hager ADZ366D FI/LS 3X 1P+N 6kA C character. 16A 30mA Type A QC
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with 3 x 1-pole circuit breaker for 230 V AC circuits and a fault current protection circuit in the compact housing. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 16 A and at the access up to 63 A, contact protection according to IP2x DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: C Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Number of modules: 4 Rated operating voltage Ue: 230 VRated current16 ATrigger characteristicCRated value6Type of differential protectionASensitivity30 mANumber4 PNumber of modules4Rated operating voltage Ue230 VInsulation voltage500 VFrequency50 HzTorque2NmTotal loss power at rated current10.9 WDevice life, electrical switching games2000Machine life mechanical switching games2000Operating temperature-5 to 40 °CStorage temperature-55 to 70 °CHeight installed product86 mmWide installed product71 mmDeep Installed Product70 mm
€108.93
Hager CDA225D fault current switch 2 polig 6kA 25A 30mA Type A
3-8 working days
Residual current circuit breaker 2-pole 6kA 25A 30mA type A. Residual current circuit breaker (FI) according to EN 61008-1, DIN EN 61008-2-1, VDE 0664 part 10 + 11, protection against accidental contact IP2x according to DIN VDE 0106 part 100 .Suitable for retrofitting additional equipment (mounting without tools). Wire push-in protection terminals, bottom bi-connect terminals, external blue test button. All products with VDE mark. Labeling option directly on the device.



Rated current
25A


Type of differential protection
A


Sensitivity
30mA


Number of Poles
2P


Surge current resistance (pulse fault currents 8/20µs)
0.25kA


Number of modules
2


Frequency
50Hz


Mounting type
DIN rail


Type of connection
screw technology


Connection cross section with flexible conductor
16mm²


Connection cross section with rigid conductor
25mm²


torque
2.8Nm


degree of protection
IP20


Insulation voltage
500V


Surge withstand voltage
4kV


Additional equipment possible
1


Operating temperature
-25 to 40 °C


Device lifetime mechanical switching cycles
4000


Device service life, electrical switching cycles
2000


Total power loss under rated current
3.4W


Degree of contamination according to IEC 60664 / IEC 60947-2
2


Height above sea level
2000m


Rated current at 20° C
25A


Rated current at 30° C
25A


Rated current at 35° C
25A


Rated current at 40° C
25A


Rated current at 45° C
25A


Rated current at 50°C
25A


Rated current at 55° C
25A


Rated current at 60°C
25A


Rated current at 65°C
25A


Rated current at 70°C
21A


Storage temperature
-55 to 70 °C


Height installed product
83mm


Wide installed product
35mm


Deep Installed Product
70mm


€64.39
Hager CDA240D fault current switch 2 polig 6kA 40A 30mA Type A
2-8 days



Rated current
40 A


Type of differential protection
A


Sensitivity
30 mA


Number
2 P


Impact current resistance (pulse fault currents 8/20μs)
0,25


Number of modules
2


Frequency
50 Hz


Assembly type
DIN rail


Connection type
Screw technology


Connection cross section with flexible conductor
16mm2


Connection cross section for rigid conductor
25mm2


Torque
2.8 Nm


Type of protection
IP20


Insulation voltage
500 V


Impact strength
4 kV


Additional equipment possible
1


Operating temperature
-25 to 40 °C


Machine life mechanical switching games
4000


Device life, electrical switching games
2000


Total loss power at rated current
9.2 W


Degree of contamination according to IEC 60664 / IEC 60947-2
2


Height above N.N.
2000 m


Rated current at 20° C
40 A


Rated current at 30° C
40 A


Rated current at 35° C
40 A


Rated current at 40° C
40 A


Rated current at 45° C
38 A


Rated current at 50°C
37 A


Rated current at 55° C
34 A


Rated current at 60°C
30 A


Rated current at 65°C
26 A


Rated current at 70°C
21 A


Storage temperature
-55 to 70 °C


Height installed product
83 mm


Wide installed product
35 mm


Deep Installed Product
70 mm


€68.18
Hager CDA425D fault current circuit breaker 4 polig 6kA 25A 30mA Type A
3-7 working days
fault current protection switch 4 polig 6kA 25A 30mA type A. fault current protection switch (FI) according to EN 61008-1, DIN EN 61008-2-1, VDE 0664 part 10 + 11, touch protection IP2x according to DIN VDE 0106 part 100. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, Bi-Connect terminals at the bottom, external blue test button. All products with VDE characters. Labeling option directly on the device.



Rated current
25 A


Type of differential protection
A


Sensitivity
30 mA


Number
4 P


Impact current resistance (pulse fault currents 8/20μs)
0,25


Number of modules
4


Frequency
50 Hz


Assembly type
DIN rail


Connection type
Screw technology


Connection cross section with flexible conductor
16mm2


Connection cross section for rigid conductor
25mm2


Torque
2.8 Nm


Type of protection
IP20


Insulation voltage
500 V


Impact strength
4 kV


Additional equipment possible
1


Operating temperature
-25 to 40 °C


Machine life mechanical switching games
4000


Device life, electrical switching games
2000


Total loss power at rated current
4.5 W


Degree of contamination according to IEC 60664 / IEC 60947-2
2


Height above N.N.
2000 m


Rated current at 20° C
25 A


Rated current at 30° C
25 A


Rated current at 35° C
25 A


Rated current at 40° C
25 A


Rated current at 45° C
25 A


Rated current at 50°C
25 A


Rated current at 55° C
25 A


Rated current at 60°C
25 A


Rated current at 65°C
22 A


Rated current at 70°C
18 A


Storage temperature
-55 to 70 °C


Height installed product
83 mm


Wide installed product
70 mm


Deep Installed Product
70 mm


€67.81
On sale!
Hager CDA440D fault current circuit breaker 4 polig 6kA 40A 30mA Type A
2-5 days
Rated current: 40 ANumber of poles: 4 PSensitivity: 30 mAType of differential protection: AImpact strength: 4 kVNumber of modules: 4AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50 HzTorque: 2,8NmConnection type: screw technologyTotal loss power at rated current: 6.5 WDevice life, electrical switching games: 2000Machine life mechanical switching games: 4000Connection cross-section with flexible conductor: 16mm2Connection cross section for rigid conductor: 25mm2Operating temperature: -25 to 40 °CStorage temperature: -55 to 70 °CHeight installed product: 83 mmWide installed product: 70 mmDeep installed product: 70 mm
€33.00
Hager CDA445D FI circuit breaker 4P 40A 30mAA type A rated current pre-sureable
2-5 days
Rated current: 40 ANumber of poles: 4 PSensitivity: 30 mAType of differential protection: AImpact strength: 4 kVNumber of modules: 4AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50 HzTorque: 2,8NmConnection type: screw technologyTotal loss power under rated current: 11.8 WDevice life, electrical switching games: 2000Machine life mechanical switching games: 4000Connection cross-section with flexible conductor: 16mm2Connection cross section for rigid conductor: 25mm2Operating temperature: -25 to 40 °CStorage temperature: -55 to 70 °CHeight installed product: 83 mmWide installed product: 70 mmDeep installed product: 70 mm
€77.13
Hager CDA463D fault current circuit breaker 4 polig 6kA 63A 30mA Type A
2-8 days
fault current protection switches 4 polig 6kA 63A 30mA type A. fault current protection switches (FI) according to EN 61008-1, DIN EN 61008-2-1, VDE 0664 part 10 + 11, touch protection IP2x according to DIN VDE 0106 part 100. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, Bi-Connect terminals at the bottom, external blue test button. All products with VDE characters. Labeling option directly on the device.



Rated current
63 A


Type of differential protection
A


Sensitivity
30 mA


Number
4 P


Impact current resistance (pulse fault currents 8/20μs)
0,25


Number of modules
4


Frequency
50 Hz


Assembly type
DIN rail


Connection type
Screw technology


Connection cross section with flexible conductor
16mm2


Connection cross section for rigid conductor
25mm2


Torque
2.8 Nm


Type of protection
IP20


Insulation voltage
500 V


Impact strength
4 kV


Additional equipment possible
1


Operating temperature
-25 to 40 °C


Machine life mechanical switching games
4000


Device life, electrical switching games
2000


Total loss power at rated current
18.5 W


Degree of contamination according to IEC 60664 / IEC 60947-2
2


Height above N.N.
2000 m


Rated current at 20° C
63 A


Rated current at 30° C
63 A


Rated current at 35° C
63 A


Rated current at 40° C
63 A


Rated current at 45° C
60 A


Rated current at 50°C
58 A


Rated current at 55° C
55 A


Rated current at 60°C
51 A


Rated current at 65°C
48 A


Rated current at 70°C
45 A


Storage temperature
-55 to 70 °C


Height installed product
83 mm


Wide installed product
70 mm


Deep Installed Product
70 mm


€125.98
Hager CDS240D fault current switch 2 polig 6kA 40A 30mA Type A QuickConnect
3-7 working days
2 polig 6kA 40A 30mA Type A QuickConnect fault current protection switch according to EN 61008-1, DIN EN 61008-2-1 and VDE 0664 Part 10 + 11. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11 at access up to 63 A, IP2x touch protection according to DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Suitable for subsequent installation of additional equipment. Nominal current: 40 A Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Impact current strength (impulsive fault currents 8/20μs): 0.25 kA Number of modules: 2 Frequency: 50 HzRated current40 AType of differential protectionASensitivity30 mANumber2 PImpact current resistance (pulse fault currents 8/20μs)0,25Number of modules2Frequency50 HzAssembly typeDIN railConnection typeQuickConnectConnection cross section with flexible conductor16mm2Connection cross section for rigid conductor25mm2Torque2.8 NmType of protectionIP20Insulation voltage500 VImpact strength4 kVAdditional equipment possible1Operating temperature-25 to 40 °CMachine life mechanical switching games4000Device life, electrical switching games2000Total loss power at rated current9.2 WDegree of contamination according to IEC 60664 / IEC 60947-22Height above N.N.2000 mRated current at 30° C40 AStorage temperature-55 to 70 °CHeight installed product83 mmWide installed product35 mmDeep Installed Product70 mm
€71.97
Hager CDS425D fault current switch 4 polig 6kA 25A 30mA Type A QuickConnect
3-7 working days
EN 61008-1, DIN EN 61008-2-1 and VDE 0664 Part 10 + 11. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11 at access up to 63 A, IP2x touch protection according to DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Suitable for subsequent installation of additional equipment. Nominal current: 25 A Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Impact current strength (impulsive fault currents 8/20μs): 0.25 kA Number of modules: 4 Frequency: 50 Hz Rated current25 AType of differential protectionASensitivity30 mANumber4 PImpact current resistance (pulse fault currents 8/20μs)0,25Number of modules4Frequency50 HzAssembly typeDIN railConnection typeQuickConnectConnection cross section with flexible conductor16mm2Connection cross section for rigid conductor25mm2Torque2.8 NmType of protectionIP20Insulation voltage500 VImpact strength4 kVAdditional equipment possible1Operating temperature-25 to 40 °CMachine life mechanical switching games4000Device life, electrical switching games2000Total loss power at rated current4.5 WDegree of contamination according to IEC 60664 / IEC 60947-22Height above N.N.2000 mRated current at 30° C25 AStorage temperature-55 to 70 °CHeight installed product83 mmWide installed product70 mmDeep Installed Product70 mm
€71.43
Hager CDS440D FI circuit breaker A 40A/4 30mA 250A, QC 4 polig 6kA 40A 30mA Type A QuickConnect
2-5 days
4pin 6kA 40A 30mA Type A QuickConnect Safety switch (FI) according to EN 61008-1, DIN EN 61008-2-1, VDE 0664 Part 10 + 11, QuickConnect - Clamp at the access for railing up to 63A IP2x according to DIN VDE 0106 part 100. Suitable for Additional equipment (mounting) without tool). Connection terminals with Wire insertion protection, external blue test button. All Products with VDE characters. Labeling option directly on the device. Rated current: 40 A Number of poles: 4 P Sensitivity: 30 mA Type of differential protection: A Impact strength: 4 kV Number of modules: 4 AC voltage: 230/400 V Frequency: 50 Hz
€77.28