List of products by brand Hager

Hager CDS463D fault current switch 4 polig 6kA 63A 30mA Type A QuickConnect
3-7 working days
4 polig 6kA 63A 30mA Type A QuickConnect fault current protection switch according to EN 61008-1, DIN EN 61008-2-1 and VDE 0664 Part 10 + 11. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11 at access up to 63 A, IP2x touch protection according to DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Suitable for subsequent installation of additional equipment. Nominal current: 63 A Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Impact current strength (impulsive fault currents 8/20μs): 0.25 kA Number of modules: 4 Frequency: 50 Hz



Rated current
63 A


Type of differential protection
A


Sensitivity
30 mA


Number
4 P


Impact current resistance (pulse fault currents 8/20μs)
0,25


Number of modules
4


Frequency
50 Hz


Assembly type
DIN rail


Connection type
Screw technology


Connection cross section with flexible conductor
16mm2


Connection cross section for rigid conductor
25mm2


Torque
2.8 Nm


Type of protection
IP20


Insulation voltage
500 V


Impact strength
4 kV


Additional equipment possible
1


Operating temperature
-25 to 40 °C


Machine life mechanical switching games
4000


Device life, electrical switching games
2000


Total loss power at rated current
18.5 W


Degree of contamination according to IEC 60664 / IEC 60947-2
2


Height above N.N.
2000 m


Rated current at 30° C
63 A


Storage temperature
-55 to 70 °C


Height installed product
83 mm


Wide installed product
70 mm


Deep Installed Product
70 mm


€132.55
On sale!-9%
Hager MCN516 LS switch 16A/1pol+N/C 6kA
2-5 Tage
Circuit breaker 1polig+N 6kA C-Characteristic 16A 2 Modules Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 16 ATrigger characteristic: CNominal shutdown capacity: 6 kANumber of poles: 2 PNumber of modules: 2AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal power loss under rated current: 4.4 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 35 mmDeep installed product: 70 mm
€7.96
€8.75
On sale!
Hager MBN513 LS switch 13A/1pol+N/B 6kA
2-5 Tage
Circuit breaker 1polig+N 6kA B-Characteristic 13A 2 Modules Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 13 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 2 PNumber of modules: 2AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power under rated current: 4.6 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 35 mmDeep installed product: 70 mm
€8.75
On sale!-5%
Hager MCN513 LS switch 13A/1pol+N/C 6kA
2-5 Tage
Circuit breaker 1polig+N 6kA C-Characteristic 13A 2 Modules Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 13 ATrigger characteristic: CNominal shutdown capacity: 6 kANumber of poles: 2 PNumber of modules: 2AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 4.2 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 35 mmDeep installed product: 70 mm
€7.34
€7.73
On sale!
Hager MCN616 LS switch 16A/3pol+N/C 6kA
2-5 days
Circuit breaker 3polig+N 6kA C-Characteristic 16A 4 Modules Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails.Rated current: 16 ATrigger characteristic: CNominal shutdown capacity: 6 kANumber of poles: 4 PNumber of modules: 4AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 8.2 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 70 mmDeep installed product: 70 mm
€35.50
On sale!
Hager CJG440D FI switch 4P 40A 30mA G/A-VSA G type pre-securable
2-5 days
FI switch 4pin 6kA 40A 30mA type G/A rated current pre-sureableRated current: 40 ANumber of poles: 4 PSensitivity: 30 mAType of differential protection: A GImpact strength: 4 kVNumber of modules: 4AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50 HzTorque: 2,8NmConnection type: screw technologyTotal loss power at rated current: 6.5 WDevice life, electrical switching games: 2000Machine life mechanical switching games: 4000Connection cross-section with flexible conductor: 16mm2Connection cross section for rigid conductor: 25mm2Operating temperature: -25 to 40 °CStorage temperature: -55 to 70 °CHeight installed product: 83 mmWide installed product: 70 mmDeep installed product: 70 mm
€69.50
Hager CDA440D fault current circuit breaker 4 polig 6kA 40A 30mA Type A
2-5 days
Rated current: 40 ANumber of poles: 4 PSensitivity: 30 mAType of differential protection: AImpact strength: 4 kVNumber of modules: 4AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50 HzTorque: 2,8NmConnection type: screw technologyTotal loss power at rated current: 6.5 WDevice life, electrical switching games: 2000Machine life mechanical switching games: 4000Connection cross-section with flexible conductor: 16mm2Connection cross section for rigid conductor: 25mm2Operating temperature: -25 to 40 °CStorage temperature: -55 to 70 °CHeight installed product: 83 mmWide installed product: 70 mmDeep installed product: 70 mm
€44.64
Hager CNA440D FI switch 4P 40A 100mA S/A-VS
2-5 days
4pin 6kA 40A 100mA type S selective fault current protection switchRated current: 40 ANumber of poles: 4 PSensitivity: 100 mAType of differential protection: A SELImpact strength: 4 kVNumber of modules: 4AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50 HzTorque: 2,8NmConnection type: screw technologyTotal loss power at rated current: 5 WDevice life, electrical switching games: 2000Machine life mechanical switching games: 4000Connection cross-section with flexible conductor: 16mm2Connection cross section for rigid conductor: 25mm2Operating temperature: -25 to 40 °CStorage temperature: -55 to 70 °CHeight installed product: 83 mmWide installed product: 70 mmDeep installed product: 70 mm
€95.40