List of products by brand Hager

Hager ADA516D fault current circuit breaker 1P+N 10kA B-16A 30mA Type A
2-5 days
1P+N 10kA B-16A 30mA Type A fault current circuit breaker according to EN 61009-1 and EN 61009-2-1. IP2x contact protection according to DIN VDE 0660 part 514. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, Bi-Connect terminals below, external blue test button for half-yearly actuation and fault current display. Easy removal from the phase rail composite. All products with VDE characters. Labeling option directly on the device. Rated current: 16 A Trigger characteristic: B Switching capacity Icn AC according to IEC 60898-1: 10 kA Type of fault current protection: A Rated fault current: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V
€52.74
Hager HAB406 power breaker 4pin 63A
2-5 days
4 pole 63A load disconnector for hat rail or mounting plate load disconnector for mounting on hat rail or mounting plate, rotary drive directly on the device in the OFF state can be locked with a padlock. Ensures switching on and off under load and a safety disconnect function in all low-voltage circuits. Rated current: 63 A Rated operating voltage Ue: 380/415 V Insulation voltage: 800 V Number of poles: 4 P Number of modules: 3.42 Operating temperature: -20 ... 70 °C Connection type: Screwing technology Connection cross-section with rigid conductor: 16mm2
€84.96
Hager HAC306 Power breaker 3pin 63A
2-5 days
Load disconnector 3pin 63A for hat rail or mounting plate Load disconnector for mounting on hat rail or mounting plate, rotary drive directly on the device in the OFF state can be locked with a padlock. Ensures switching on and off under load and a safety disconnect function in all low-voltage circuits. Rated current: 63 A Rated operating voltage Ue: 380/415 V Isolation voltage: 800 V Number of poles: 3 P Number of modules: 3 Operating temperature: -20 ... 70 °C Connection type: Screwing technology Connection cross-section with rigid conductor: 35mm2
€75.75
Hager ADZ363D FI/LS 3X 1P+N 6kA C character. 13A 30mA Type A QC
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with 3 x 1-pole circuit breaker for 230 V AC circuits and a fault current protection circuit in the compact housing. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 16 A and at the access up to 63 A, contact protection according to IP2x DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 13 A Trigger characteristic: C Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Number of modules: 4 Rated operating voltage Ue: 230 V



Rated current
13 A


Trigger characteristic
C


Rated value
6


Type of differential protection
A


Sensitivity
30 mA


Number
4 P


Number of modules
4


Rated operating voltage Ue
230 V


Insulation voltage
500 V


Frequency
50 Hz


Torque
2Nm


Total loss power at rated current
9.6 W


Device life, electrical switching games
2000


Machine life mechanical switching games
2000


Operating temperature
-5 to 40 °C


Storage temperature
-55 to 70 °C


Height installed product
86 mm


Wide installed product
71 mm


Deep Installed Product
70 mm


€133.56
Hager SU215 Summer 230V/0,03A, 6.5VA 1 PLE
2-8 days
Summer for DIN rail with protection against short circuit or overload through an integrated thermal switch on the primary side, continuous operation up to 1 hour. Total loss power at rated current:6,5 W
€33.62