List of products by brand Eaton

Eaton PLSM-C10-MW LS switch 10A/1pol/C 242202
2-5 days
Trigger characteristicCNumber of poles (total)1Number of secured poles1Rated currentA10Measurement voltageV230Measurement switching capacity Icn according to EN 60898 at 230 VKA10Measurement switching capacity Icn according to EN 60898 at 400 VKA10Measurement switching capacity Icu according to IEC 60947-2 at 230 VKA0Measurement switching capacity Icu according to IEC 60947-2 at 400 VKA0Type of voltageACEnergy limiting class3FrequencyHZ50 to 60Interconnecting neutral conductornoSuitable for underground installationnoOvervoltage category3Pollution2Width in division units1Installation depthmmANNEXAdditional equipment possibleyesType of protection (IP)IP20
€5.74
EATON PLSM-B13/3N-MW LS switch 13A/3pol+N/B 242515
2-5 days




Auslösecharakteristik

 
 
B



Polzahl (gesamt)

 
 
4



Anzahl der abgesicherten Pole

 
 
4



Bemessungsstrom

 
A
13



Bemessungsspannung

 
V
400



Bemessungsschaltvermögen Icn nach EN 60898 bei 230 V

 
kA
10



Bemessungsschaltvermögen Icn nach EN 60898 bei 400 V

 
kA
10



Bemessungsschaltvermögen Icu nach IEC 60947-2 bei 230 V

 
kA
0



Bemessungsschaltvermögen Icu nach IEC 60947-2 bei 400 V

 
kA
0



Spannungsart

 
 
AC



Energiebegrenzungsklasse

 
 
3



Frequenz

 
Hz
50 - 60



Mitschaltender Neutralleiter

 
 
ja



Geeignet für Unterputz-Installation

 
 
nein



Überspannungskategorie

 
 
3



Verschmutzungsgrad

 
 
2



Breite in Teilungseinheiten

 
 
4



Einbautiefe

 
mm
70.5



Zusatzeinrichtungen möglich

 
 
ja



Schutzart (IP)

 
 
IP20


€42.00
Eaton PLSM-C6-MW LS switch 6A/1pol/C 242200
2-5 days
Trigger characteristicCNumber of poles (total)1Number of secured poles1Rated currentA6Measurement voltageV230Measurement switching capacity Icn according to EN 60898 at 230 VKA10Measurement switching capacity Icn according to EN 60898 at 400 VKA10Measurement switching capacity Icu according to IEC 60947-2 at 230 VKA0Measurement switching capacity Icu according to IEC 60947-2 at 400 VKA0Type of voltageACEnergy limiting class3FrequencyHZ50 to 60Interconnecting neutral conductornoSuitable for underground installationnoOvervoltage category3Pollution2Width in division units1Installation depthmmANNEXAdditional equipment possibleyesType of protection (IP)IP20
€8.35
On sale!
Eaton Überspannungsableiter steckbar, 3p+N, 280VAC, 20kA 167620
2-5 days
For the protection of consumer equipment against transient overvoltages caused by indirect flashes and switching operations, test class II according to IEC 61643-1+A1, SPD type T2 according to EN 61643-11, auxiliary switch SPC-S-HK for remote control, displaceable with all Xtra Combination switching devices caused by indirect flashes and switching operations, test class II according to IEC 61643-1+
€97.00
Eaton PLSM-C6/1N-MW LS switch 6A/1pol+N/C 242266
2-5 days
Trigger characteristicCNumber of poles (total)2Number of secured poles2Rated currentA6Measurement voltageV230Measurement switching capacity Icn according to EN 60898 at 230 VKA10Measurement switching capacity Icn according to EN 60898 at 400 VKA10Measurement switching capacity Icu according to IEC 60947-2 at 230 VKA0Measurement switching capacity Icu according to IEC 60947-2 at 400 VKA0Type of voltageACEnergy limiting class3FrequencyHZ50 to 60Interconnecting neutral conductoryesSuitable for underground installationnoOvervoltage category3Pollution2Width in division units1.5Installation depthmmANNEXAdditional equipment possibleyesType of protection (IP)IP20
€16.80
Eaton Neozed sleeve adapter D02/50A 50GN02
2-5 days
Safety accessories, fit insert for fuse, low voltage, 50 A, AC 400 V, D02, IEC, color coded, E18, prevents the insertion of fuse insert with incorrect current value
€0.26
Eaton PLSM-B6-MW LS switch 6A/1pol/B 242174
2-5 days
Trigger characteristicBNumber of poles (total)1Number of secured poles1Rated currentA6Measurement voltageV230Measurement switching capacity Icn according to EN 60898 at 230 VKA10Measurement switching capacity Icn according to EN 60898 at 400 VKA10Measurement switching capacity Icu according to IEC 60947-2 at 230 VKA0Measurement switching capacity Icu according to IEC 60947-2 at 400 VKA0Type of voltageACEnergy limiting class3FrequencyHZ50 to 60Interconnecting neutral conductornoSuitable for underground installationnoOvervoltage category3Pollution2Width in division units1Installation depthmmANNEXAdditional equipment possibleyesType of protection (IP)IP20
€8.35
Eaton SPCT2-335-335-3+NPE overvoltage arrester 3+N 335VAC 20kA 167622
2-5 days




Design of poles



3 + N / P



Rated leakage current (8/20)


KA
20



Rated voltage AC


V
335



Rated voltage DC


V
0



Maximum permanent voltage AC


V
335



Highest continuous voltage DC


V
0



Max. PV voltage


V
0



Protection level


KV
1.6



Protection level L-N


KV
0



Protection level N-PE


KV
0



Short circuit



no



Assembly type



Hat rail 35 mm



Size



4 THE



Max. Conductor cross-section rigid (one/multiple)


mm2
25



Max. Conductor cross section flexible (fine)


mm2
0



With telecommunication contact



no



Integrated Preservation



no



Signaling on the device



optical



Test class type 2



yes



Type of protection (IP)



IP20


€98.40
Eaton Z-SV-10/3P+3N-3TE/13 Block displacement 13TE (Stift) End caps 10mm2, 50A, 4-ph 264927
2-5 days
Block displacement for PLN. (1TE), delivery with end capsNumber of phases4Number3Suitable for number of devices13Partial dimensionmm1795Cross-sectionmm210Lengthmm232Number of division units3Duration of measurement IuA50Design of the electrical connectionPinInsulatedyesMeasurement surge voltageKV0Conditional measurement short-circuit current IqKA25Max. Rated operating voltage UeV415Measurement short-term current resistance IcwKA0Suitable for N-wire devicesyesSuitable for devices with auxiliary switchno
€33.58
On sale!
Eaton SPBT12-280/3 Overvoltage arrester 3pin 280V, TN-C set 158330
2-5 days
For the protection of consumer equipment against transient overvoltages caused by direct and indirect flashes, as well as switching operations, application according to IEC 60364-5-53 Section 534, test classes I, II according to IEC 61643-1, SPD type T1, T2 according to EN 61643-11, flash protection class III and IV according to IEC 62305, execution without remote message




Net form



TN-C



Design of poles



3



Rated leakage current (8/20)


KA
25



Rated voltage AC


V
280



Rated voltage DC


V
0



Maximum permanent voltage AC


V
280



Highest continuous voltage DC


V
0



Max. PV voltage


V
0



Protection level


KV
1.5



Protection level L-N


KV
0



Protection level N-PE


KV
0



Short circuit



no



Assembly type



Hat rail 35 mm



Size



THREE TEA



Max. Conductor cross-section rigid (one/multiple)


mm2
25



Max. Conductor cross section flexible (fine)


mm2
0



With telecommunication contact



no



Integrated Preservation



no



Signaling on the device



optical



Test class type 2



yes



Type of protection (IP)



IP20


€173.90