Best sellers

Eaton PLSM-B6-MW LS switch 6A/1pol/B 242174
2-5 days
Trigger characteristicBNumber of poles (total)1Number of secured poles1Rated currentA6Measurement voltageV230Measurement switching capacity Icn according to EN 60898 at 230 VKA10Measurement switching capacity Icn according to EN 60898 at 400 VKA10Measurement switching capacity Icu according to IEC 60947-2 at 230 VKA0Measurement switching capacity Icu according to IEC 60947-2 at 400 VKA0Type of voltageACEnergy limiting class3FrequencyHZ50 to 60Interconnecting neutral conductornoSuitable for underground installationnoOvervoltage category3Pollution2Width in division units1Installation depthmmANNEXAdditional equipment possibleyesType of protection (IP)IP20
€8.36
Berker 3037 cross switch insert
2-7 days
Rated voltage: 250 V ACSwitching current: 10 AXConnection terminals: according to VDE 0632-1for lighting and control circuitwith connectors
€14.90
Eaton Z-SV-10/3P+3N-3TE/13 Block displacement 13TE (Stift) End caps 10mm2, 50A, 4-ph 264927
2-5 days
Block displacement for PLN. (1TE), delivery with end capsNumber of phases4Number3Suitable for number of devices13Partial dimensionmm1795Cross-sectionmm210Lengthmm232Number of division units3Duration of measurement IuA50Design of the electrical connectionPinInsulatedyesMeasurement surge voltageKV0Conditional measurement short-circuit current IqKA25Max. Rated operating voltage UeV415Measurement short-term current resistance IcwKA0Suitable for N-wire devicesyesSuitable for devices with auxiliary switchno
€33.59
On sale!
Eaton SPBT12-280/3 Overvoltage arrester 3pin 280V, TN-C set 158330
2-5 days
For the protection of consumer equipment against transient overvoltages caused by direct and indirect flashes, as well as switching operations, application according to IEC 60364-5-53 Section 534, test classes I, II according to IEC 61643-1, SPD type T1, T2 according to EN 61643-11, flash protection class III and IV according to IEC 62305, execution without remote message




Net form



TN-C



Design of poles



3



Rated leakage current (8/20)


KA
25



Rated voltage AC


V
280



Rated voltage DC


V
0



Maximum permanent voltage AC


V
280



Highest continuous voltage DC


V
0



Max. PV voltage


V
0



Protection level


KV
1.5



Protection level L-N


KV
0



Protection level N-PE


KV
0



Short circuit



no



Assembly type



Hat rail 35 mm



Size



THREE TEA



Max. Conductor cross-section rigid (one/multiple)


mm2
25



Max. Conductor cross section flexible (fine)


mm2
0



With telecommunication contact



no



Integrated Preservation



no



Signaling on the device



optical



Test class type 2



yes



Type of protection (IP)



IP20


€173.91
Berker W1 47843515 AP outlet with hinged lid 2x horizontal W.1 grey matt IP55
2-5 days
IP55Nennial voltage: 250 V ACRated current: 16 AOperating temperature: -40/60 °CConnection terminals: according to VDE 0620-1with full-surface seal on the rear side of the housing for rear line introduction and cleaning compensation with falling flap cover, manually lockable with 2 snap-in places for Wago 2-wire connection clamps in housing bottom with Wago 2-wire connection terminal for horizontal mounting with an introduction for 2 lines and an introduction for pipe or pipe Wired inserts with connectors The upper and lower introduction for lines are arranged laterally offset and are therefore particularly suitable for mounting next to door frames or the like. Stainless steel hinged cover springs, pins of the ZAMAK quick release. grey/light grey matt 2 line introductions
€21.60
On sale!
BEG Bewegungsmelder LUXOMAT LC-plus-280-WS weiß
2-5 days
Adjustable ball head optics with up to 280° detection range and 360° under creep protectionCovering of unneeded detection zones by clipping steplessly displaceable lamellae (borons), whereby all detection areas below 280°, such as, for example, 130° or 230°, can be realized.Special base for outdoor rear mounting includedFixed work program for immediate commissioning with set twilight value of about 20 lux and a follow-up time of 3 minutesAdjustment of insulation value and follow-up time via two potentiometers on the underside of the ball headOption: Remote control IR-LC-plus or IR-LC-Mini for additional settings, such as continuous light ON or OFF at any time.Easy mounting by single-hand plug baseAreas of application:e.g. house entrances, garage and plot entrances or whole house pagesPower supply: 110 – 240 VAC, 50/60 HzSwitching power:2000 W, cosφ =1, 1000 VA, cosφ =0.5Range: approx. 16 m (tangential)Time setting: approx. 15 s - 16 min.Twilight switch: approx. 2 - 2000 LuxProtection class: IP44 / II / CEDimensions: L 100 x B 68 x H 78 mmHigh-quality UV-resistant polycarbonate housingAmbient temperature: -25°C to +50°C
€77.76
Perforated tape metal mounting tape 12x0.7 mm, corrugated hole 5.1 mm, L10 m Siblik
2-3 Days


Metal mounting bandHollow assembly belt – side edge “well” – the ideal universal fastening!
The easy formability makes the assembly belt a universal problem-solving device.
The area of application ranges from ceiling suspension to self-bent fastening clamp.
Band length: 10 m
Thickness: 0.7 mm
Width: 12 mm
Hole: 5.1 mm
Material: galvanized steel strip
Packaging unit: 10 pcs.
Packaging: in practical plastic roll-off box

perforated metal mounting band, corrugated or straight
easy formability
Application: from ceiling suspension to self-bent fastening clamp
Material: galvanized steel strip
Band length: 10 m
Packaging: in practical plastic roll-off box



€3.60
PROTEC.class PWDB26510AA Wiring bridge 265mm
2-7 days
Wiring bridges AE/AE. For wiring of LS,- FI,- and similar switching devices. For example, for installation small distributors and counter positions according to WDE 0603. EN 60439-1 / WDE 0660, part 500. WDE 0100, part 523: 6 mm2: max. 54 A, 10 mm2: max. 73 A. Rated voltage: 450 / 750 W. Insulation material: PWTSC (type of lead H07V-K). Head: Flexible. Cable end: Aderend sleeve on both sides. Color: black. Length: 265 mm cross-section: 10 mm2
€1.64
Eaton PFIM-40/4/003-A-MW FI circuit breaker A 40A/4 30mA 250A 235439
2-5 days




Number



4



Measurement voltage


V
400



Rated current


A
40



Measurement error current


A
0.03



Assembly type



DIN rail



Error current type



A



Selective type



no



Short-circuit strength (Icw)


KA
10



Impact resistance


KA
0.25



Frequency



50 Hz



Additional equipment possible



yes



Type of protection (IP)



IP20



Size (according to DIN 43880)



1



Width in division units



4



Installation depth


mm
ANNEX



Short-term delayed type



no


€85.21