Best sellers

Hager ADA566D 1P+N 10kA C-16A 30mA Type A
2-5 days
1P+N 10kA C-16A 30mA Type A fault current circuit breaker according to DIN VDE 0664 Part 20 / EN61009-1 and DIN VDE 0664 Part 21 / EN61009-2-1. Contact protection according to DIN VDE 0660 part 514. Bi-Connect terminals below, blue test button and fault current display. Easy removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Rated current: 16 A Trigger characteristic: C Switching capacity Icn AC according to IEC 60898-1: 10 kA Type of fault current protection: A Rated fault current: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V
€63.00
Hager ADA563D FI/LS 1P+N 10kA C-13A 30mA Type A
2-5 days
1P+N 10kA C-13A 30mA type A fault current circuit breaker according to EN 61009-1 and EN 61009-2-1. IP2x contact protection according to DIN VDE 0660 part 514. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, Bi-Connect terminals below, external blue test button for half-yearly actuation and fault current display. Easy removal from the phase rail composite. All products with VDE characters. Labeling option directly on the device. Rated current: 13 A Trigger characteristic: C Switching capacity Icn AC according to IEC 60898-1: 10 kA Type of fault current protection: A Rated fault current: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V
€69.85
Out-of-Stock
Jung A 1750 D WW Timer Standard, Display
Out-of-Stock
Timer Standard, with display, switching on solar or. Sunset (Astro function, adjustable for 18 countries,) Locking function, display switches off after 2 minutes, permanent display of the current time possible, programming each of one run-up and one run-off time for the weekly sections Mo - Fr and Sa - So, programming of two in- and two out commands for the weekly sections Mo - Fr and Sa - So, ventilation position of the attachment
Jung UAE 8 UPOK6E Data Box, Category 6 / Class E, Shielded LSA Plus Terminals, 8-pin
2-7 days
Data box, Category 6, Shielded LSA Plus Terminal Terminals, 8-pin, for 1 terminal, fulfilled requirements: RJ-45 Connection Boxes for Networks by Category 6, Class E (1 Gbit/s / 250 MHz), equivalent Cat. 6/Class E according to. ISO/IEC 11801:2011-06 and DIN EN 50173-1:2011-09 = 2500 plug-in cycles, suitable for RJ 11/12, suitable for Poe+ according to IEEE 802.3at
€27.62
Jung 3069-2 SIE Assembly adapter 30 °
2-7 days
N230, 3M: VOL-0001, VOL-0002, VOLOCK6ASND8, Assmann: DN 93612, DN 93615, Metzconnect (BTR): 130A10-I, 130B23-E, 130B21-E, Cobinet: 6920 0052, Dätwyler: 418 061, eku: t66851000, t668509. Adapter Keystone,) SETEC: 501415, 501414, SIEMON: MX6-K., MX5-K., Z6A-SK(XX), Z5A-SK(XX), Z6A-K01, Z6A-01, MX5-F01, MX6-01, MX6-F01, Z5-S01, MX5-01, Z6-K01
€5.75
Jung EDA 302 F Antenna Can, Universal-Sat/BK, 3-hole, Single dose
2-7 days
WHICH: TW, TW, TW, TW, TW, TW, TW, TW, TW, TW, TW, TW, TW, TW, TW, TW, TW, TW, TW, TW. + 24 V / 0.5 A, torsion-resistant, passivated zinc die casting can body, spring clamps, connection options on BK cable network or terrestrial antenna systems (all-round-dose), single box, termination of the uncoupled stub lines (stern structure) coming from the branch (multi-tap), multi-switch or Sat-LNB
€32.73