Best sellers

Eltako ESR12NP-230V+UC Electric shock relay
3-10 days
Current surge relays for mounting on support rails DIN-EN 60715 TH35 16A/250V AC not potential-free, control input 230W AC and additional universal control voltage 8 to 230W UC, with rotary switches for the functions ER = switching relays, ES = current surge switches and ESW = current surge switches with reverse deceleration of 2 to 120 minutes plus switchable switch-off warning and push-off light. Relapse delay with switch-off warning and push-button continuous light can be switched on. Stand-by loss only 0.5 Watt. Contact circuit in the zero passage for protecting the contacts and lamps, in particular this extends the service life of energy-saving lamps. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Control voltage additionally with galvanically separated universal control voltage. Very low switching noise. Precise time setting of the relapse delay RV in the function ESW from 2 to 120 minutes with minute scale. With control LED. This flashes after 15 minutes with blocked probe (not in function ER). At the 230V control input Glow lamp current up to 150ma, regardless of the ignition voltage (not in function ER). In the relay functions suitable for feedback with the switching voltage of a dimming switch. If the supply voltage fails, it is switched off in a defined manner. The current surge switch automatically switches off after the set delay time has expired if the manual out command has not been given. Time range up to 120 minutes adjustable.
€47.91
Eltako S12-100-12V AC STROMSTOSSCHALEN
3-10 days
Current surge switches for mounting on support rails DIN-EN 60715 TH35 rated switching power 16 A / 250 W AC or. 10 A / 400 W AC with manual actuation and switching position display mechanical storage of the switching position Number of locks: 1 width in division units: 1 dimensioning switching current: 16 A control voltage 1: 12 - W control voltage type 1: AC installation depth: 55 mm assembly type: DIN rail frequency of control voltage 1: 50 - 50 Hz voltage type of supply voltage: AC supply voltage range: 250 - 250 W Max. Bulb load: 2300 W Max. Lamp load: 2300 VA Max. Fluorescent lamp load (Duo circuit): 2300 VA Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 10 A manual operation possible: Yes Electromechanical power surge switch with manual actuation and switching position display. Switch-on time 100%. 5-6W. Contact distance 3mm. Distance control connections/contact > 6mm. Suitable for connection to an SELV network.
€19.25
Kathrein ESD 30 Einzelanschlussdose 3fach
2-5 Tage
Bei durchgehenden Frequenzbalken werden auch die Frequenzlücken unter- und oberhalb des FM-Bereiches und zwischen UHF- und Sat-ZF-Bereich übertragen. Einzeldose (1x IEC TV, 1x IEC Radio, 1x F-Sat). Überträgt Fernspeisespannung über den Sat-Auslass
€10.48
H07V-K YF 2,5 GELB-GRÜN flexible Verdrahtungsleitung 100m
2-5 Tage
PVC Verdrahtungsleitung Verwendung: In trockenen Räumen, in Betriebsmitteln, Schalt- und Verteilungsanlagen und als Potentialausgleichsleitung in Rohr auf und unter Putz sowie bei geschützter Verlegung in und an Leuchten. Für innere Verdrahtung von Geräten mit einer Nennspannung bis 1000 V Wechselstrom und mit einer Nennspannung bis 750 V Gleichstrom gegen Erde. Nicht zulässig für unmittelbare Verlegung in Putz.
€48.02
Berker 47516089 outlet SCHUKO m folding lid Q1/Q3 polar white
2-7 days
Socket SCHUKO with hinged cover Q.1/Q.3 polar white, velvet. SCHUKO® socket with self-closing hinged cover, with increased contact protection, with imprint, with plug clamps according to WDE 0620 designed and approved as connecting clamps, with one-piece grounding bracket. Underput installation, area program. Material: plastic, thermoplastic, break-proof, halogen-free. SCHUKO® socket with self-closing hinged cover, with increased contact protection, with imprint, with plug clamps according to WDE 0620 designed and approved as connecting clamps, with one-piece grounding bracket. Underput installation, area program. Material: plastic, thermoplastic, break-proof, halogen-free.
€22.04
XYMM-J 5x2,5 50m Bund PVC-Baustellenleitung K35 GE
2-5 Tage
PVC Baustellenleitung Verwendung: Für den Anschluss von Betriebsmitteln besonders auf Baustellen. In trockenen und feuchten Räumen, im Freien und in explosionsgefährdeten Betrieben.
€191.67
Pipelife MM50 Flexmuff 50 tension resistant gr 15 pieces
2-5 days
Flexmuff, grey similar to RAL 7037, infgest and dense, made of halogen-free base material, non-flammable, for medium mechanical stress, for flexible electrical installation pipes for tight and tensile connection of pipes
€18.45
Hager CDA240D fault current switch 2 polig 6kA 40A 30mA Type A
2-8 days



Rated current
40 A


Type of differential protection
A


Sensitivity
30 mA


Number
2 P


Impact current resistance (pulse fault currents 8/20μs)
0,25


Number of modules
2


Frequency
50 Hz


Assembly type
DIN rail


Connection type
Screw technology


Connection cross section with flexible conductor
16mm2


Connection cross section for rigid conductor
25mm2


Torque
2.8 Nm


Type of protection
IP20


Insulation voltage
500 V


Impact strength
4 kV


Additional equipment possible
1


Operating temperature
-25 to 40 °C


Machine life mechanical switching games
4000


Device life, electrical switching games
2000


Total loss power at rated current
9.2 W


Degree of contamination according to IEC 60664 / IEC 60947-2
2


Height above N.N.
2000 m


Rated current at 20° C
40 A


Rated current at 30° C
40 A


Rated current at 35° C
40 A


Rated current at 40° C
40 A


Rated current at 45° C
38 A


Rated current at 50°C
37 A


Rated current at 55° C
34 A


Rated current at 60°C
30 A


Rated current at 65°C
26 A


Rated current at 70°C
21 A


Storage temperature
-55 to 70 °C


Height installed product
83 mm


Wide installed product
35 mm


Deep Installed Product
70 mm


€81.82