List of products by brand Hager

Hager HTS163E SLS switch 1P E-63A busbar L2
2-7 days
SLS switch 1 polig E-characteristic 63A for busbar Quickconnect. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 Baugroesse 6. SLS in different pole shape, one-pole switching, with separate contact position display. Plug contacting for direct busbar mounting. The standard multifunction closure allows the following locks: 1.for the customer to switch against unintentional or intentional, 2.for the installer with a padlock when working in the system, 3.for the WNB with plomb wire, padlock or special key.
€73.33
Hager HTN150E SLS switch 1P E-50A DIN rail
2-7 days
SLS switch 1 polig E-characteristic 50A for DIN rail mounting. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 size 2. SLS in 1- or 3-pole design, one-pole switching, with separate contact position display. For direct mounting on a hat rail. The standard (no suggestions) allows the following limitations: for the customer against unintentional or intentional switching; for the installer with a padlock when working in the plant; for the WNB with plombier wire, padlock or special key.
€73.33
Hager HTS125E SLS switch 1P E-25A busbar QC
2-7 days
SLS switch 1 polig E-characteristic 25A for busbar Quickconnect. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 Size 6. SLS in different pole shape, one-pole switching, with separate contact position display. Plug contacting for direct busbar mounting. The standard multi-function closure allows the following closures: for the customer against unintentional or misconductive switching, for the installer with a padlock when working in the plant, for the WNB with plomb wire, padlock or special key.
€69.37
Hager HTS150E SLS switch 1P E-50A busbar QC
2-7 days
SLS switch 1 polig E-characteristic 50A for busbar Quickconnect. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 Size 6. SLS in different pole shape, one-pole switching, with separate contact position display. Plug contacting for direct busbar mounting. The standard multi-function closure allows the following closures: for the customer against unintentional or misconductive switching, for the installer with a padlock when working in the plant, for the WNB with plomb wire, padlock or special key.
€73.33
Hager HTN163E SLS switch 1P E-63A DIN rail
2-7 days
SLS switch 1 polig E-characteristic 63A for DIN rail mounting. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 size 2. SLS in 1- or 3-pole design, one-pole switching, with separate contact position display. For direct mounting on a hat rail. The standard (no suggestions) allows the following limitations: for the customer against unintentional or intentional switching; for the installer with a padlock when working in the plant; for the WNB with plombier wire, padlock or special key.
€75.32
Hager ADA516D fault current circuit breaker 1P+N 10kA B-16A 30mA Type A
2-5 days
1P+N 10kA B-16A 30mA Type A fault current circuit breaker according to EN 61009-1 and EN 61009-2-1. IP2x contact protection according to DIN VDE 0660 part 514. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, Bi-Connect terminals below, external blue test button for half-yearly actuation and fault current display. Easy removal from the phase rail composite. All products with VDE characters. Labeling option directly on the device. Rated current: 16 A Trigger characteristic: B Switching capacity Icn AC according to IEC 60898-1: 10 kA Type of fault current protection: A Rated fault current: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V
€62.37
Hager HAB306 power breaker 3pin 63A
2-5 days
Load disconnector 3pin 63A for hat rail or mounting plate Load disconnector for mounting on hat rail or mounting plate, rotary drive directly on the device in the OFF state can be locked with a padlock. Ensures switching on and off under load and a safety disconnect function in all low-voltage circuits. Rated current: 63 A Rated operating voltage Ue: 380/415 V Isolation voltage: 800 V Number of poles: 3 P Number of modules: 2.57 Operating temperature: -20 ... 70 °C Connection type: Screwing technology Connection cross-section with rigid conductor: 16mm2
€63.76
Hager HAC308 3pin 80A
2-5 days
3pin 80A load disconnector for hat rail or mounting plate load disconnector for mounting on hat rail or mounting plate, rotary drive directly on the device in the OFF state can be locked with a padlock. Ensures switching on and off under load and a safety disconnect function in all low-voltage circuits. Rated current: 80 A Rated operating voltage Ue: 380/415 V Isolation voltage: 800 V Number of poles: 3 P Number of modules: 3 Operating temperature: -20 ... 70 °C Connection type: Screwing technology Connection cross-section with rigid conductor: 35mm2
€84.44
hager HAC408 Lasttrennschalter 4polig 80A
2-5 days
4 pole 80A load disconnector for hat rail or mounting plate load disconnector for mounting on hat rail or mounting plate, rotary drive directly on the device in the OFF state can be locked with a padlock. Ensures switching on and off under load and a safety disconnect function in all low-voltage circuits. Rated current: 80 A Rated operating voltage Ue: 380/415 V Isolation voltage: 800 V Number of poles: 4 P Number of modules: 4 Operating temperature: -20 ... 70 °C Connection type: Screwing technology Connection cross-section with rigid conductor: 35mm2
€115.21