Hager KH25C Hauptl. Breakdown. 5P, 2x25/2x16mm2, fingerproof
2-8 days



Number
5 P


Connection cross section for rigid conductor
1.5 - 25mm2


Torque
2.8 Nm


Rated voltage
400 V


Rated current
80 A


Colour
pure white RAL 9010


Assembly type
Locked and screwable


Height installed product
65.9 mm


Wide installed product
102.4 mm


Deep Installed Product
45,5 mm


€21.82
Hager MBN613 LS switch 13A/3pol+N/B 6kA
2-5 days
Circuit breaker 3polig+N 6kA B-Characteristic 13A 4 modules circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 13 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 4 PNumber of modules: 4AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 6.7 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 70 mmDeep installed product: 70 mm
€38.00
Hager MCS316 LS switch 16A/3pol/C 6kA, QC QuickConnect cable protection switch 3 polig 6kA C-characteristics 16A 3 modules
2-5 days
3polig 6kA C-characteristic 16A Quick Connect 3 Modules Cable protection switch with QuickConnect - terminal DIN EN 60898-1 (VDE 0641 part 11):2003-12; EN 60898-1:2003; EN 60898-1, pr A1:2003, at the exit to 16A and access for the deposit up to 63A. Contact protection according to IP2x DIN VDE 0106 part 100 with VDE Signs. LS with time-delayed thermal trigger for Overload protection and electromagnetic trigger for Short circuit protection. Suitable for retrofit cultivation of Additional equipment; Labeling option directly at Device and individual withdrawal from the phase rail composite by unlatching the quick-fit rail mounting. Rated current: 16 A Trigger characteristic: C Nominal shutdown capacity: 6 kA Number of poles: 3 P Number of modules: 3 Operating voltage AC current: 230/400 V Frequency: 50/60 Hz Connection type: QuickConnect
€33.36
Hager GD108N Mini distributor AP,Gamma,1x8TE,o.door,B182xH180xT82mm
2-5 Tage
Mini distributor IP30 8 space units Mini distributor as micro distributor made of plastic for the installation of row-mounted units according to the standard DIN 43 880 as contact protection cover according to BGV A2 for Geraete up to 63 A, 400 V /50 Hz, protection class IP30. For splash mounting with 46 mm barley slot, serially plombable.Mounting type: plasterMaterial of housing: plasticProtection type: IP30Protection class: Protection class IINumber of distribution rows: 1RAL colour number: 9010Number of modules: 8Color: whiteDoor closure type: without closureHeight installed product: 180 mmWide installed product: 182 mmDeep installed product: 82 mm
€17.43
Hager KJ10AT counter clamp AC 50A
2-7 days
Counter clamp AC 50A counter connection clamp designed as a counter clamp for the fast and secure installation and arm of energy meters of different manufacturers and systems with counter pin spacing according to DIN 43857. The counter clamp was tested according to ÖVE R21:2015 with 50A rated current when using the standard pin and is available with an extensive accessory.
€26.33
On sale!
Hager VU48AT Kleinverteiler UP,Volta,4x12(+2)TE,IP30,B335xH740xT90mm
2-5 days



Number of rows:
4


Width in division units:
12


Material of housing:
Plastic


Protection type (IP):
IP30


Height:
755 mm


Width:
348 mm


Depth:
94.5 mm


Installation depth:
94.5 mm


With transparent lid:
No


Access:
Yes


EMC version:
No


Color:
white


RAL number:
9010


€82.20
Hager SBN116 Switch 1P 16A
2-5 days
Switch 16A 1 Locker 230V AC 1PLE Switch off according to EN 60669-1/669-2-4 with VDE characters, IP2x touch protection according to BGV A3. Suitable for retrofit installation of additional equipment; Labeling option directly on the device. Rated current: 16 ANumber of poles: 1 PNumber of modules: 1AC voltage: 230 VInsulation voltage: 440 VImpact strength: 4000 VFrequency: 50/60 HzConnection type: screw technologyTotal loss power at rated current: 0.4 WMachine life mechanical switching games: 200000Connection cross section for flexible conductor: 1.5 - 10mm2Connection cross section for rigid conductor: 1.5 - 16mm2Operating temperature: -20 to 50 °CStorage temperature: -40 to 80 °CHeight installed product: 83 mmWide installed product: 17.5 mmDeep installed product: 68 mm
€11.69
Hager ADG513D FI/LS 1P+N 10kA B- 13A 30mA Type A-G
2-5 days
1P+N 10kA B- 13A 30mA type A-G fault current circuit breaker according to EN 61009-1 and EN 61009-2-1, short-term delayed according to ÖVE E 8601. IP2x contact protection according to DIN VDE 0660 part 514. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, Bi-Connect terminals below, external blue test button for half-yearly actuation and fault current display. Easy removal from the phase rail composite. All products with ÖVE characters. Labeling option directly on the device. Nominal current: 13 A Trigger characteristic: B Switching capacity Icn AC according to IEC 60898-1: 10 kA type of fault current protection: A G Rated fault current: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 230 V
€74.84
Hager MBN625 LS switch 25A/3pol+N/B 6kA
2-5 days
3polig+N 6kA B-Characteristic 25A 4 ModulesCircuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 25 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 4 PNumber of modules: 4AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 10,1 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 70 mmDeep installed product: 70 mm
€72.04
Hager MBN106 LS switch 6A/1pol/B circuit breaker 1 polig 6kA B-characteristic 6A 1 module
2-5 days
Rated current: 6 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 1 PNumber of modules: 1AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 1.3 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 17.5 mmDeep installed product: 70 mm
€9.22