Eltako WNT12-12VDC-12W1A Wide-switched.
Eltako WNT12-12VDC-12W1A Wide-switched.
3-10 days
Wide-range switching power supply for mounting on support rail DIN-EN 60715 TH35 overload and overtemperature protection by disconnecting with automatic switch-on after the fault removal (autorecovery function) wide-range switching power supply. Stand-by-loss only 0.2 Watt. With a load greater than 50% of the rated power and always with adjacent switching power supply components greater than 12 watts of rated power, and with dimmers, a 1/2 division unit is required on both sides with the distance pieces DS12. Efficiency 83%. Stabilized output voltage ±1%, low residual ripple. Short circuit. Overload and overtemperature protection by switching off with automatic switching on after eliminating errors (autorecovery function). Secondary voltage 1: 12 W Width: 18 mm Max. Output power: 12 W Max. Output current: 1.0 A width in division units: 1
€62.41
Eltako WNT12-12VDC-24W/2A power supply
Eltako WNT12-12VDC-24W/2A power supply
3-10 days
Wide-range switching power supply for mounting on support rail DIN-EN 60715 TH35 overload and overtemperature protection by disconnecting with automatic switch-on after the fault removal (autorecovery function) wide-range switching power supply. Stand-by-loss only 0.2 Watt. With a load greater than 50% of the rated power and always with adjacent switching power supply components greater than 12 watts of rated power, and with dimmers, a 1/2 division unit is required on both sides with the distance pieces DS12. Efficiency 83%. Stabilized output voltage ±1%, low residual ripple. Short circuit. Overload and overtemperature protection by switching off with automatic switching on after eliminating errors (autorecovery function). Secondary voltage 1: 12 W Width: 36 mm Max. Output power: 24 W Max. Output current: 2.0 A width in division units: 2
€68.96
Eltako WNT12-24VDC-12W/0.5A power supply
Eltako WNT12-24VDC-12W/0.5A power supply
3-10 days
Wide-range switching power supply for mounting on support rail DIN-EN 60715 TH35 overload and overtemperature protection by disconnecting with automatic switch-on after the fault removal (autorecovery function) wide-range switching power supply. Stand-by-loss only 0.2 Watt. With a load greater than 50% of the rated power and always with adjacent switching power supply components greater than 12 watts of rated power, and with dimmers, a 1/2 division unit is required on both sides with the distance pieces DS12. Efficiency 86%. Stabilized output voltage ±1%, low residual ripple. Short circuit. Overload and overtemperature protection by switching off with automatic switching on after eliminating errors (autorecovery function). Secondary voltage 1: 24 W Width: 18 mm Max. Output power: 12 W Max. Output current: 0.5 A width in division units: 1
€62.41
Eltako WNT12-24VDC-24W/1A power supply
Eltako WNT12-24VDC-24W/1A power supply
3-10 days
Wide-range switching power supply for mounting on support rail DIN-EN 60715 TH35 Overload and overtemperature protection by switching off with automatic switching on after the fault elimination (autorecovery function) secondary voltage 1: 24 W Width: 36 mm Max. Output power: 24 W Max. Output current: 1.0 A width in division units: 2 wide range switching power supply. Stand-by-loss only 0.2 Watt. With a load greater than 50% of the rated power and always with adjacent switching power supply components greater than 12 watts of rated power, and with dimmers, a 1/2 division unit is required on both sides with the distance pieces DS12. Efficiency 87%. Stabilized output voltage ±1%, low residual ripple. Short circuit. Overload and overtemperature protection by switching off with automatic switching on after eliminating errors (autorecovery function).
€68.96
Eltako WSZ15D-32A MID AC counter MID ge
Eltako WSZ15D-32A MID AC counter MID ge
3-10 days
Electronic AC meter for mounting on support rail DIN-EN 60715 TH35, maximum current 32A, stand-by loss only 0.4 Watt, accuracy class B (1)%, with SO interface TLE: 1 current A: 5(32) Certified: MID calibrated tariff version of the electricity meter: tariff
€74.42
Eltako WSZ15D-65A MID AC counter MID ge
Eltako WSZ15D-65A MID AC counter MID ge
3-10 days
Electronic AC meter for mounting on support rail DIN-EN 60715 TH35, maximum current 32A, stand-by-loss only 0.4 Watt, accuracy class B (1)%, with S0 interface TLE: 1 current A: 5(65) Certified: Yes
€91.81
Eltako WSZ15DE-32A AC counter
Eltako WSZ15DE-32A AC counter
3-10 days
Electronic AC meter AC counters without approval for support rail. Stand-by loss only 0.5 Watt. Accuracy class B (1) % With S0 interface. This alternating current meter measures the active energy on the basis of the current flowing between the input and the output. The own consumption of only a maximum of 0.5 watt active power is not measured and not displayed. Like all counters without PTB or MID approval in Germany not approved for monetary current billing. Every 30 seconds, the display switches from the accumulated active energy to the instantaneous consumption in Watt for 5 seconds. 1 external conductor can be connected with a current up to 32A. In the event of a load to be expected of more than 50%, a ventilation distance of 1/2 division unit is to be maintained for devices mounted next to it. If the spacer DS12 is used. The starting current is 20ma. The display can only be read with power supply. However, the consumption is non-volatile and will be displayed immediately after a power failure. Two N-terminals for secure cross wiring of several counters. The decimal point which flashes depending on the power consumption indicates a power reference. In case of false connection, false appears in the display. The digital display has 7 digits. Up to 99999,99kWh, two descendants are displayed. From 100000.0kWh only one. Even with only theoretically conceivable maximum current reference, the display would be suitable for more than 15 years. The power reference is displayed with the decimal point. TLE: 1 Certified: No Measurement voltage: 230 W
€59.02
Eltako XR12-100-230VAC INSTALLATION PROCESS
Eltako XR12-100-230VAC INSTALLATION PROCESS
3-10 days
Installation protector series installation device with manual actuation and switching position display. AC-types with rectifier, therefore free of bruise and reduced power loss. Rated switching power 25 A/250 W AC, manual operation and switching position indicator. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W. Voltage type of operating voltage: AC Number of locks: 1 Number of openers: 0 Protection type (IP): IP20 Number of division units: 1 Max. Bulb load: 2300 W Rated operating current: 25 A Rated operating voltage: 250 - 250 W Max. Fluorescent lamp load (parallel compensated): 1000 VA Max. Fluorescent lamp load (Duo circuit): 3600 VA Max. Fluorescent lamp load: 3600 VA Additional devices possible: Yes Voltage type of actuating voltage: AC Mounting depth: 55 mm
€25.24
Eltako XR12-110-230VAC INSTALLATION PROTECTION
Eltako XR12-110-230VAC INSTALLATION PROTECTION
3-10 days
Installation protector series installation device with manual actuation and switching position display. AC-types with rectifier, therefore free of bruise and reduced power loss. Rated switching power 25 A/250 W AC, manual operation and switching position indicator. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W. Voltage type of operating voltage: AC Number of locks: 1 Number of openers: 1 Protection type (IP): IP20 Number of division units: 1 Max. Bulb load: 2300 W Rated operating current: 25 A Rated operating voltage: 250 - 250 W Max. Fluorescent lamp load (parallel compensated): 1000 VA Max. Fluorescent lamp load (Duo circuit): 3600 VA Max. Fluorescent lamp load: 3600 VA Additional devices possible: Yes Voltage type of actuating voltage: AC Mounting depth: 55 mm
€29.62
Eltako XR12-200-230VAC INSTALLATION PROTECTION
Eltako XR12-200-230VAC INSTALLATION PROTECTION
3-10 days
Installation protector series installation device with manual actuation and switching position display. AC-types with rectifier, therefore free of bruise and reduced power loss. Rated switching power 25 A/250 W AC, voltage type of operating voltage: AC Number of switches: 2 Number of openers: 0 Protection type (IP): IP20 Number of division units: 1 Max. Bulb load: 2300 W Rated operating current: 25 A Rated operating voltage: 250 - 250 W Max. Fluorescent lamp load (parallel compensated): 1000 VA Max. Fluorescent lamp load (Duo circuit): 3600 VA Max. Fluorescent lamp load: 3600 VA Additional devices possible: Yes Voltage type of actuating voltage: AC Mounting depth: 55 mm Installation contactor with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W.
€29.62
Eltako XR12-220-230V AC INSTALLATION RELAY
Eltako XR12-220-230V AC INSTALLATION RELAY
3-10 days
Switching relays for day rails DIN EN 50022, rated switching power 25 A/250 W AC Installation contactor with manual actuation and switching position display. Switch-on time 100%. 4W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W. Voltage type for actuation: AC Number of contacts as closer: 2 Number of contacts as opener: 2 Rated control voltage Us at AC 50 Hz: 230 - W
€48.09
Eltako XS12-400-230V AC STROMSTOSS
Eltako XS12-400-230V AC STROMSTOSS
3-10 days
Current surge switches for support rails DIN EN 50022,Nenn Switching Power 25 A/250 W AC Number of locks: 4 Rated switch current: 25 A Control voltage 1: 230 - W Control voltage type 1: AC Mounting depth: 55 mm Installation type: DIN rail Frequency of control voltage 1: 50 - 50 Hz Voltage type of supply voltage: AC Supply voltage range: 250 - 250 W Max. Bulb load: 2300 W Max. Lamp load: 3600 VA Max. Fluorescent lamp load (Duo circuit): 3600 VA Max. Fluorescent lamp load (parallel compensated): 1000 VA Max. Switching current (cos phi = 0.6): 15 A manual operation possible: Yes Electromechanical current surge switch with manual actuation and switching position display. Only pulse control. 12-15W. Contact distance 3mm.
€47.65