Eltako

Eltako NLZ61NP-230V Restart switch 1 S
3-10 days
After running switch for installation not potential-free 10A/250V AC, stand-by-loss only 0.7 Watt, contact circuit in the zero passage for the protection of the contacts and consumers, state-of-the-art hybrid technology combines the advantages of wear-free electronic control with the high power of special relays, control voltage, supply and switching voltage 230W, follow-up time 1 to 12 minutes, response delay 0 to 12 minutes control voltage 1: 230 - 230 W. Time range from/to: 0 - 12 2. Time range from/to: 12 - 1 function: response and fall delay Number of locks: 1 switching power bulbs: 2000 W supply voltage range: 250 - 250 W installation height: 18 mm rated current at 250 W AC: 10 A switching power fluorescent lamps DUO: 1000 VA 1. Time range unit: minutes/hours 2. Time range unit: seconds/minutes assembly type: Unterputz follow-up switch 230W. 1 lock not potential-free 10A/250V AC. Stand-by-loss only 0.7 Watt. For installation. 45mm long, 45mm wide, 18mm deep. Contact circuit in the zero passage to protect the contacts and consumers. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Control voltage, supply and switching voltage 230W. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Adjustable with the upper rotary switch for 1 to 12 minutes. Response delay 0 to 12 minutes with the lower rotary switch adjustable. Function: With the closing of the control contact (light switch), the response delay AV (if not set 0) begins, at whose end the fan is switched on wi
€37.97
Eltako NLZ61NP-8..230V UC Relay
3-10 days
Relay relays for installation and AP-assembly follow-up switches, locks not potential-free, follow-up time can be adjusted steplessly up to 12 minutes, contact circuit in the zero passage to protect the contacts and consumers. Rated switching power 10 A/250 W AC control voltage 1: 8 - 230 W control voltage type 1: AC/DC frequency of control voltage 1: 50 - 50 Hz switching power fluorescent lamps parallel: 500 VA 1. Time range from/to: 12 - 0 2. Time range from/to: 12 - 1 function: response and fall delay Number of locks: 1 switching power bulbs: 2000 W supply voltage range: 250 - 250 W installation height: 18 mm rated current at 250 W AC: 10 A switching power fluorescent lamps DUO: 1000 VA 1. Time range unit: minutes/hours 2. Time range unit: seconds/minutes Mounting type: Unterputz. 1 lock not potential-free 10A/250V AC. Stand-by loss only 0.7 Watt. For installation. 45mm long, 45mm wide, 18mm deep. Contact circuit in the zero passage to protect the contacts and consumers. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Universal control voltage 8..230V UC galvanically isolated from the supply and switching voltage 230W. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Adjustable with the upper rotary switch for 1 to 12 minutes. Response delay 0 to 12 minutes with the lower rotary switch adjustable. Function: With the closing of the control contact (light switch), the response delay AV (if not set 0) begins at whose end the fan is switched on. After opening the control contact and if a set response delay had already expired, the set
€39.35
Eltako NO12-0013x230V network monitoring relays
3-10 days
Power monitoring relay for mounting on support rail DIN-EN 60715 TH35, for monitoring 230 W AC voltage against the zero conductor, drop delay adjustable 0.1 to 8 seconds, draw delay 0.5 s, LED display for applied voltage, with the lower rotary switch on the front side two draw-on or respectively. Relapse voltages are set: U1: 161W drop-back voltage and 185V draw voltage U2: 196W drop-back voltage and 206W draw-on voltage according to. WDE 0100 part 718 network monitoring relay with field monitoring. Stand-by-loss only 0.8 Watt. Mounting unit for mounting on support rail (1TE) For monitoring 230W AC voltage between 1 to 3 external conductors and the neutral conductor and for monitoring the rotary field (rotating in the right) in the rotary switch positions 2ph and 3ph. In the position L1/L2/L3, only the rotary field is monitored, regardless of the mains voltage. Supply voltage L1-N 180-250V/50Hz. If L1 fails, the relay will drop immediately without a relapse delay. With the lower rotary switch on the front side, two draw or. Relapse voltages are set and the number of monitored external conductors must be specified. U1: 161W falling voltage and 185V tightening voltage. U2: 196W falling voltage and 206W tightening voltage according to. WDE 0100, Part 718 (formerly: WDE 0108, Part 1). LED display for correct applied voltage. In case of incorrect polarity or a missing external conductor, the LED flashes quickly. Relapse delay RV with the upper rotary switch adjustable from 0.1 to 8 seconds. While the RV time is running, the LED flashes slowly. Suit delay 0.5s. Maximum device protection 16A. Number of contacts as changer: 1 TLE: 1
€44.85
Eltako NR12-002-3X230V NEWS
3-10 days
Power monitoring relay for mounting on support rail DIN-EN 60715 TH35, for monitoring 230 W AC voltage against the zero conductor, drop delay adjustable 0.1 to 8 seconds, draw delay 0.5 s, LED display for applied voltage, with the lower rotary switch on the front side two draw-on or respectively. Relapse voltages are set: U1: 161W drop-back voltage and 185V draw voltage U2: 196W drop-back voltage and 206W draw-on voltage according to. WDE 0100 part 718 network monitoring relay with field monitoring. Stand-by loss only 0.8 Watt. Mounting unit for mounting on support rail (2 TE). For monitoring 230W AC voltage between 1 to 3 external conductors and the neutral conductor and for monitoring the rotary field (rotating in the right) in the rotary switch positions 2ph and 3ph. In the position L1/L2/L3, only the rotary field is monitored, regardless of the mains voltage. If L1 fails, the relay will drop immediately without a relapse delay. With the lower rotary switch on the front side, two draw or. Relapse voltages are set and the number of monitored external conductors must be specified. U1: 161W falling voltage and 185V tightening voltage. U2: 196W falling voltage and 206W tightening voltage according to. WDE 0100, Part 718 (formerly: WDE 0108, Part 1). LED display for correct applied voltage. In case of incorrect polarity or a missing external conductor, the LED flashes quickly. Relapse delay RV with the upper rotary switch adjustable from 0.1 to 8 seconds. While the RV time is running, the LED flashes slowly. Suit delay 0.5s. Number of contacts as changer: 2 TLE: 2
€58.63
Eltako P3K12-230V PHASENKONTROL
3-10 days
Design of the electrical connection screw connection, measurement control supply voltage Us at AC 50 Hz 230 ... 400V, measurement control supply voltage Us at AC 60 Hz 230 ... 400V, voltage type for actuation AC, function phase failure detection, width 17.5mm, for optical monitoring of 1 to 3 phases 230 V. Display by three red light-emitting diodes for 230 V AC. Number of contacts as locks: 0 Number of contacts as openers: 0 Type of electrical connection: Screw connection Type of voltage for actuation: AC Number of contacts as changer: 0 Width: 18 mm Height: 58 mm Depth: 58 mm Function Overvoltage detection: No Rated control voltage Us at AC 50 Hz: 230 - 230 V With removable clamps: No Function Phase sequence detection: No Function. Series installation unit with 1 division unit. For optical monitoring of 1 to 3 external conductors 230V. Display with three red light-emitting diodes.
€36.89
Eltako R12-100-12V AC INSTALLATION RELAY
3-10 days
Switching relay for mounting on support rails DIN-EN 60715 TH35 rated switching power 16 A/250 W AC or. 10 A/400 W AC Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W. Number of contacts as closer: 1 Voltage type for actuation: AC TLE: 1 Rated control voltage Us at AC 50 Hz: 12 - W
€16.04
Eltako R12-100-12VDC INSTALLATION RELAY
3-10 days
Switching relay for mounting on support rails DIN-EN 60715 TH35 rated switching power 16 A/250 W AC or. 10 A/400 W AC Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W. Number of contacts as closer: 1 TLE: 1 Rated control voltage Us at AC 50 Hz: 12 - W Voltage type for actuation: DC
€23.61
Eltako R12-100-230V AC INSTALLATION RELAY
3-10 days
Switching relays for mounting on support rails DIN-EN 60715 TH35 Rated switching power 16 A/250 V AC or 10 A/400 V AC Number of contacts as closer: 1 Voltage type for actuation: AC TLE: 1 Rated control voltage Us at AC 50 Hz: 230 - V Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000V and test voltage Control connections/contact 4000V.
€16.04
Eltako R12-100-24V AC INSTALLATION RELAY
3-10 days
Switching relay for mounting on support rails DIN-EN 60715 TH35 rated switching power 16 A/250 W AC or. 10 A/400 W AC Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W. Number of contacts as closer: 1 Voltage type for actuation: AC TLE: 1 Rated control voltage Us at AC 50 Hz: 24 - W
€18.01
Eltako R12-100-24VDC INSTALLATION RELAY
3-10 days
Switch relays for mounting on support rails DIN-EN 60715 TH35 Rated switching power 16 A/250 W AC or 10 A/400 W AC Number of contacts as closer: 1 TLE: 1 Rated control voltage Us at AC 50 Hz: 24 - W Voltage type for actuation: DC Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W.
€23.61
Eltako R12-100-8V AC INSTALLATION RELAY
3-10 days
Switching relays for mounting on support rails DIN-EN 60715 TH35 Rated switching power 16 A/250 W AC or 10 A/400 W AC Number of contacts as closer: 1 TLE: 1 Rated control voltage Us at AC 50 Hz: 8 - W Voltage type for actuation: AC Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W.
€18.01
Eltako R12-110-12VDC INSTALLATION RELAY
3-10 days
Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W. Mounting type: DIN rail Measurement current: 16 A Number of lockers: 1 Number of changers: 0 Number of openers: 1 Width in division units: 1 Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Fluorescent lamp load (Duo circuit): 2300 VA Max. Incandescent lamp load: 2300 W supply voltage range: 230 - 230 W control voltage 1: 12 - 12 W control voltage type 1: DC frequency of control voltage 1: 50 - 50 Hz Max. Fluorescent lamp load: 2300 VA voltage type of supply voltage: DC Max. Switching current (cos phi = 0.6): 10 A Installation depth: 55 mm Function: other
€29.12