FI/LS switch

Hager ADS910D FI/LS 1P+N 6kA B-Characteristic 10A 30mA
2-5 days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 10 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V



Rated current
10 A


Trigger characteristic
B


Rated value
6


Type of differential protection
A


Sensitivity
30 mA


Number
2 P


Number of modules
2


Rated operating voltage Ue
240 V


Insulation voltage
500 V


Impact strength
4,000 V


Frequency
50 Hz


Torque
2.1Nm


Total loss power at rated current
3.4 W


Device life, electrical switching games
2000


Machine life mechanical switching games
2000


Connection cross section with flexible conductor
1 - 16mm2


Connection cross section for rigid conductor
1 - 25mm2


Operating temperature
-25 to 40 °C


Storage temperature
-25 to 70 °C


Height installed product
94 mm


Wide installed product
35 mm


Deep Installed Product
68 mm


€72.00
Hager ADA563D FI/LS 1P+N 10kA C-13A 30mA Type A
2-5 days
1P+N 10kA C-13A 30mA type A fault current circuit breaker according to EN 61009-1 and EN 61009-2-1. IP2x contact protection according to DIN VDE 0660 part 514. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, Bi-Connect terminals below, external blue test button for half-yearly actuation and fault current display. Easy removal from the phase rail composite. All products with VDE characters. Labeling option directly on the device. Rated current: 13 A Trigger characteristic: C Switching capacity Icn AC according to IEC 60898-1: 10 kA Type of fault current protection: A Rated fault current: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V
€69.85
Hager ADA566D 1P+N 10kA C-16A 30mA Type A
2-5 days
1P+N 10kA C-16A 30mA Type A fault current circuit breaker according to DIN VDE 0664 Part 20 / EN61009-1 and DIN VDE 0664 Part 21 / EN61009-2-1. Contact protection according to DIN VDE 0660 part 514. Bi-Connect terminals below, blue test button and fault current display. Easy removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Rated current: 16 A Trigger characteristic: C Switching capacity Icn AC according to IEC 60898-1: 10 kA Type of fault current protection: A Rated fault current: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V
€63.00
Hager ADS966D FI/LS 1P+N 6kA C-Characteristic 16A 30mA
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: C Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V



Rated current
16 A


Trigger characteristic
C


Rated value
6


Type of differential protection
A


Sensitivity
30 mA


Number
2 P


Number of modules
2


Rated operating voltage Ue
240 V


Insulation voltage
500 V


Impact strength
4,000 V


Frequency
50 Hz


Torque
2.1Nm


Total loss power at rated current
5.2 W


Device life, electrical switching games
2000


Machine life mechanical switching games
2000


Connection cross section with flexible conductor
1 - 16mm2


Connection cross section for rigid conductor
1 - 25mm2


Operating temperature
-25 to 40 °C


Storage temperature
-25 to 70 °C


Height installed product
94 mm


Wide installed product
35 mm


Deep Installed Product
68 mm


€62.40
Hager ADA516D fault current circuit breaker 1P+N 10kA B-16A 30mA Type A
2-5 days
1P+N 10kA B-16A 30mA Type A fault current circuit breaker according to EN 61009-1 and EN 61009-2-1. IP2x contact protection according to DIN VDE 0660 part 514. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, Bi-Connect terminals below, external blue test button for half-yearly actuation and fault current display. Easy removal from the phase rail composite. All products with VDE characters. Labeling option directly on the device. Rated current: 16 A Trigger characteristic: B Switching capacity Icn AC according to IEC 60898-1: 10 kA Type of fault current protection: A Rated fault current: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V
€52.74
Hager ADZ363D FI/LS 3X 1P+N 6kA C character. 13A 30mA Type A QC
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with 3 x 1-pole circuit breaker for 230 V AC circuits and a fault current protection circuit in the compact housing. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 16 A and at the access up to 63 A, contact protection according to IP2x DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 13 A Trigger characteristic: C Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Number of modules: 4 Rated operating voltage Ue: 230 V



Rated current
13 A


Trigger characteristic
C


Rated value
6


Type of differential protection
A


Sensitivity
30 mA


Number
4 P


Number of modules
4


Rated operating voltage Ue
230 V


Insulation voltage
500 V


Frequency
50 Hz


Torque
2Nm


Total loss power at rated current
9.6 W


Device life, electrical switching games
2000


Machine life mechanical switching games
2000


Operating temperature
-5 to 40 °C


Storage temperature
-55 to 70 °C


Height installed product
86 mm


Wide installed product
71 mm


Deep Installed Product
70 mm


€133.56
Hager ADS906D FI/LS 1P+N 6kA B-Characteristic 6A 30mA
2-5 days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 6 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V



Rated current
6A


Trigger characteristic
B


Rated value
6


Type of differential protection
A


Sensitivity
30 mA


Number
2 P


Number of modules
2


Rated operating voltage Ue
240 V


Insulation voltage
500 V


Impact strength
4,000 V


Frequency
50 Hz


Torque
2.1Nm


Total loss power at rated current
1.9 W


Device life, electrical switching games
2000


Machine life mechanical switching games
2000


Connection cross section with flexible conductor
1 - 16mm2


Connection cross section for rigid conductor
1 - 25mm2


Operating temperature
-25 to 40 °C


Storage temperature
-25 to 70 °C


Height installed product
94 mm


Wide installed product
35 mm


Deep Installed Product
68 mm


€74.40