List of products by brand Hager

Hager CDA240D Fehlerstromschutzschalter 2 polig 6kA 40A 30mA Typ A
Hager CDA240D fault current switch 2 polig 6kA 40A 30mA Type A
Out-of-Stock
Rated current40 AType of differential protectionASensitivity30 mANumber2 PImpact current resistance (pulse fault currents 8/20μs)0,25Number of modules2Frequency50 HzAssembly typeDIN railConnection typeScrew technologyConnection cross section with flexible conductor16mm2Connection cross section for rigid conductor25mm2Torque2.8 NmType of protectionIP20Insulation voltage500 VImpact strength4 kVAdditional equipment possible1Operating temperature-25 to 40 °CMachine life mechanical switching games4000Device life, electrical switching games2000Total loss power at rated current9.2 WDegree of contamination according to IEC 60664 / IEC 60947-22Height above N.N.2000 mRated current at 20° C40 ARated current at 30° C40 ARated current at 35° C40 ARated current at 40° C40 ARated current at 45° C38 ARated current at 50°C37 ARated current at 55° C34 ARated current at 60°C30 ARated current at 65°C26 ARated current at 70°C21 AStorage temperature-55 to 70 °CHeight installed product83 mmWide installed product35 mmDeep Installed Product70 mm
Hager CDA425D Fehlerstromschutzschalter 4 polig 6kA 25A 30mA Typ A
Hager CDA425D fault current circuit breaker 4 polig 6kA 25A 30mA Type A
Out-of-Stock
fault current protection switch 4 polig 6kA 25A 30mA type A. fault current protection switch (FI) according to EN 61008-1, DIN EN 61008-2-1, VDE 0664 part 10 + 11, touch protection IP2x according to DIN VDE 0106 part 100. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, Bi-Connect terminals at the bottom, external blue test button. All products with VDE characters. Labeling option directly on the device.Rated current25 AType of differential protectionASensitivity30 mANumber4 PImpact current resistance (pulse fault currents 8/20μs)0,25Number of modules4Frequency50 HzAssembly typeDIN railConnection typeScrew technologyConnection cross section with flexible conductor16mm2Connection cross section for rigid conductor25mm2Torque2.8 NmType of protectionIP20Insulation voltage500 VImpact strength4 kVAdditional equipment possible1Operating temperature-25 to 40 °CMachine life mechanical switching games4000Device life, electrical switching games2000Total loss power at rated current4.5 WDegree of contamination according to IEC 60664 / IEC 60947-22Height above N.N.2000 mRated current at 20° C25 ARated current at 30° C25 ARated current at 35° C25 ARated current at 40° C25 ARated current at 45° C25 ARated current at 50°C25 ARated current at 55° C25 ARated current at 60°C25 ARated current at 65°C22 ARated current at 70°C18 AStorage temperature-55 to 70 °CHeight installed product83 mmWide installed product70 mmDeep Installed Product70 mm
Hager CDS463D Fehlerstromschutzschalter 4 polig 6kA 63A 30mA Typ A QuickConnect
Hager CDS463D fault current switch 4 polig 6kA 63A 30mA Type A QuickConnect
Out-of-Stock
4 polig 6kA 63A 30mA Type A QuickConnect fault current protection switch according to EN 61008-1, DIN EN 61008-2-1 and VDE 0664 Part 10 + 11. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11 at access up to 63 A, IP2x touch protection according to DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Suitable for subsequent installation of additional equipment. Nominal current: 63 A Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Impact current strength (impulsive fault currents 8/20μs): 0.25 kA Number of modules: 4 Frequency: 50 Hz Rated current63 AType of differential protectionASensitivity30 mANumber4 PImpact current resistance (pulse fault currents 8/20μs)0,25Number of modules4Frequency50 HzAssembly typeDIN railConnection typeScrew technologyConnection cross section with flexible conductor16mm2Connection cross section for rigid conductor25mm2Torque2.8 NmType of protectionIP20Insulation voltage500 VImpact strength4 kVAdditional equipment possible1Operating temperature-25 to 40 °CMachine life mechanical switching games4000Device life, electrical switching games2000Total loss power at rated current18.5 WDegree of contamination according to IEC 60664 / IEC 60947-22Height above N.N.2000 mRated current at 30° C63 AStorage temperature-55 to 70 °CHeight installed product83 mmWide installed product70 mmDeep Installed Product70 mm
Hager HTN340E SLS switch 3P E-40A DIN rail
Hager HTN340E SLS switch 3P E-40A DIN rail
Out-of-Stock
SLS switch 3 polig E-characteristic 40A for DIN rail mounting. SH switch according to E-DIN VDE 0641-21 and standard DIN 43 880 size 2. SLS in 1- or 3-pole design, one-pole switching, with separate contact position display. For direct mounting on a hat rail. The standard (no suggestions) allows the following limitations: for the customer against unintentional or intentional switching; for the installer with a padlock when working in the plant; for the VNB with plombier wire, padlock or special key.
Hager HTN350E SLS switch 3P E-50A DIN rail
Hager HTN350E SLS switch 3P E-50A DIN rail
Out-of-Stock
SLS switch 3 polig E-characteristic 50A for DIN rail mounting. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 size 2. SLS in 1- or 3-pole design, one-pole switching, with separate contact position display. For direct mounting on a hat rail. The standard (no suggestions) allows the following limitations: for the customer against unintentional or intentional switching; for the installer with a padlock when working in the plant; for the WNB with plombier wire, padlock or special key.
Hager HTN335E SLS switch 3P E-35A DIN rail
Hager HTN335E SLS switch 3P E-35A DIN rail
Out-of-Stock
SLS switch 3 polig E-Characteristic 35A for DIN rail mounting. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 size 2. SLS in 1- or 3-pole design, one-pole switching, with separate contact position display. For direct mounting on a hat rail. The standard (no suggestions) allows the following limitations: for the customer against unintentional or intentional switching; for the installer with a padlock when working in the plant; for the WNB with plombier wire, padlock or special key.
Hager CEA440D fault current circuit breaker 4 polig 6kA 40A 100mA Type A
Hager CEA440D fault current circuit breaker 4 polig 6kA 40A 100mA Type A
Out-of-Stock
fault current circuit breaker 4 polig 6kA 40A 100mA type A fault current circuit breaker (FI) according to EN 61008-1, EN 61008-2-1; VDE 0664 part 10 + 11, IP2x contact protection according to DIN VDE 0106 part 100. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, Bi-Connect terminals at the bottom, external blue test button for semi-annual actuation and fault current tools. Easy removal from the phase rail composite. All products with ÖVE and VDE characters. Labeling option directly on the device. Prevention: 25A according to OVE E 8101: 2019 or. limiting the operating current through downstream fuses. Rated current: 40 A Type of fault current protection: A Rated fault current: 100 mA Number of poles: 4 P Impact current strength (stand current shape 8/20 μs): 0.25 kA Number of modules: 4 Frequency: 50 Hz
Hager HIM404 Load switch 4pin 40A
Hager HIM404 Load switch 4pin 40A
Out-of-Stock
4 pole 40A for DIN rail/mounting plate Modular 4 pole switch according to DIN EN 60947-3, for switching over under load of 2 low voltage circuits. With safety separation and 3 switching positions I-0-II. Suitable for mounting on hat rail or mounting plate. Rated current: 40 A Rated operating voltage Ue: 380/415 V Number of poles: 4 P Operating temperature: -20 ... 70 °C Connection type: Screwing technology
Hager HIM406 Load switch 4pin 63A
Hager HIM406 Load switch 4pin 63A
Out-of-Stock
4pin 63A for DIN rail/mounting plate Modular 4pin switch according to DIN EN 60947-3, for switching over under load of 2 low voltage circuits. With safety separation and 3 switching positions I-0-II. Suitable for mounting on hat rail or mounting plate. Rated current: 63 A Rated operating voltage Ue: 380/415 V Number of poles: 4 P Operating temperature: -20 ... 70 °C Connection type: Screwing technology
Hager MCN620 LS switch 20A/3pol+N/C 6kA circuit breaker 3 polig+N
Hager MCN620 LS switch 20A/3pol+N/C 6kA circuit breaker 3 polig+N
Last items in stock
3pin+N cable protection switch according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails.Rated current:20 ATrigger characteristic:CNominal deactivation capacity:6Number of poles:4 PNumber of modules:4AC voltage:OF 230/400 VInsulation voltage:500 VFrequency:50/60 HzConnection type:Screw technologyTorque:2.8 NmTotal power loss under rated current:8.9 WDevice life, electrical switching games:4000Machine life mechanical switching games:20000Operating temperature:-25 to 60 °CStorage temperature:-25 to 80 °CHeight installed product:83 mmWide installed product:70 mmDeep Installed Product:70 mm
€72.02
Hager CJS440D FI-Schalter 4P 6kA 40A 30mA Typ G/A-VS
Hager CJS440D FI switch 4P 6kA 40A 30mA type G/A-VS
2-5 days
FI switch 4P 6kA 40A 30mA type G/A-VS. fault current protection switch (FI) according to EN 61008-1, EN 61008-2-1; VDE 0664 part 10 + 11, short-term delayed according to ÖVE E 8601, IP2x contact protection according to DIN VDE 0106 part 100. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, QuickBusbar according to EN 60898-1, external blue test button for semi-annual actuation and fault current tools. Easy removal from the phase rail composite. All products with ÖVE and VDE characters. Labeling option directly on the device. Preservation: 40A according to OVE E 8101: 2019 or. limiting the operating current through downstream fuses.
€91.82
Hager MBS513 LS switch 13A/1pol+N/B 6kA,QC QuickConnect
Hager MBS513 LS switch 13A/1pol+N/B 6kA,QC QuickConnect
2-5 days
Circuit breaker 1P+N 6kA B-13A Quick Connect 2MRated current: 13 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 2 PNumber of modules: 2AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: QuickConnectTorque: 2,8NmTotal loss power under rated current: 4.6 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83.4 mmWide installed product: 35 mmDeep installed product: 70 mm
€13.33
Hager CDS240D Fehlerstromschutzschalter 2 polig 6kA 40A 30mA Typ A QuickConnect
Hager CDS240D fault current switch 2 polig 6kA 40A 30mA Type A QuickConnect
3-7 working days
2 polig 6kA 40A 30mA Type A QuickConnect fault current protection switch according to EN 61008-1, DIN EN 61008-2-1 and VDE 0664 Part 10 + 11. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11 at access up to 63 A, IP2x touch protection according to DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Suitable for subsequent installation of additional equipment. Nominal current: 40 A Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Impact current strength (impulsive fault currents 8/20μs): 0.25 kA Number of modules: 2 Frequency: 50 HzRated current40 AType of differential protectionASensitivity30 mANumber2 PImpact current resistance (pulse fault currents 8/20μs)0,25Number of modules2Frequency50 HzAssembly typeDIN railConnection typeQuickConnectConnection cross section with flexible conductor16mm2Connection cross section for rigid conductor25mm2Torque2.8 NmType of protectionIP20Insulation voltage500 VImpact strength4 kVAdditional equipment possible1Operating temperature-25 to 40 °CMachine life mechanical switching games4000Device life, electrical switching games2000Total loss power at rated current9.2 WDegree of contamination according to IEC 60664 / IEC 60947-22Height above N.N.2000 mRated current at 30° C40 AStorage temperature-55 to 70 °CHeight installed product83 mmWide installed product35 mmDeep Installed Product70 mm
€76.05