List of products by brand Hager

Hager ADZ366D FI/LS 3X 1P+N 6kA C-Charakt. 16A 30mA Typ A QC
Hager ADZ366D FI/LS 3X 1P+N 6kA C character. 16A 30mA Type A QC
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with 3 x 1-pole circuit breaker for 230 V AC circuits and a fault current protection circuit in the compact housing. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 16 A and at the access up to 63 A, contact protection according to IP2x DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: C Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Number of modules: 4 Rated operating voltage Ue: 230 VRated current16 ATrigger characteristicCRated value6Type of differential protectionASensitivity30 mANumber4 PNumber of modules4Rated operating voltage Ue230 VInsulation voltage500 VFrequency50 HzTorque2NmTotal loss power at rated current10.9 WDevice life, electrical switching games2000Machine life mechanical switching games2000Operating temperature-5 to 40 °CStorage temperature-55 to 70 °CHeight installed product86 mmWide installed product71 mmDeep Installed Product70 mm
€124.50
Hager ADG966D FI/LS 16A/1+N/C/30mA G/A fault current circuit breaker 1P+N 6kA C-16A 30mA A-G type
Hager ADG966D FI/LS 16A/1+N/C/30mA G/A fault current circuit breaker 1P+N 6kA C-16A 30mA A-G type
2-5 days
Rated current: 16 ATrigger characteristic: CNominal shutdown capacity: 6 kAType of differential protection: A GSensitivity: 30 mANumber of poles: 2 PNumber of modules: 2AC voltage: 240 VInsulation voltage: 500 VImpact strength: 4000 VFrequency: 50 HzConnection type: screw technologyTorque: 2.1NmTotal loss power at rated current: 5.2 WDevice life, electrical switching games: 2000Machine life mechanical switching games: 2000Connection cross section for flexible conductor: 1 - 16mm2Connection cross section for rigid conductor: 1 - 25mm2Operating temperature: -25 to 40 °CStorage temperature: -25 to 70 °CHeight installed product: 83 mmWide installed product: 35 mmDeep installed product: 68 mm
€124.36
hager HAC408 Lasttrennschalter 4polig 80A
hager HAC408 Lasttrennschalter 4polig 80A
2-5 days
4 pole 80A load disconnector for hat rail or mounting plate load disconnector for mounting on hat rail or mounting plate, rotary drive directly on the device in the OFF state can be locked with a padlock. Ensures switching on and off under load and a safety disconnect function in all low-voltage circuits. Rated current: 80 A Rated operating voltage Ue: 380/415 V Isolation voltage: 800 V Number of poles: 4 P Number of modules: 4 Operating temperature: -20 ... 70 °C Connection type: Screwing technology Connection cross-section with rigid conductor: 35mm2
€115.21
Hager CNA440D FI switch 4P 40A 100mA S/A-VS
Hager CNA440D FI switch 4P 40A 100mA S/A-VS
2-5 days
4pin 6kA 40A 100mA type S selective fault current protection switchRated current: 40 ANumber of poles: 4 PSensitivity: 100 mAType of differential protection: A SELImpact strength: 4 kVNumber of modules: 4AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50 HzTorque: 2,8NmConnection type: screw technologyTotal loss power at rated current: 5 WDevice life, electrical switching games: 2000Machine life mechanical switching games: 4000Connection cross-section with flexible conductor: 16mm2Connection cross section for rigid conductor: 25mm2Operating temperature: -25 to 40 °CStorage temperature: -55 to 70 °CHeight installed product: 83 mmWide installed product: 70 mmDeep installed product: 70 mm
€112.80
Hager ADS906D FI/LS 1P+N 6kA B-Charakteristik 6A 30mA
Hager ADS906D FI/LS 1P+N 6kA B-Characteristic 6A 30mA
2-5 days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 6 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V Rated current6ATrigger characteristicBRated value6Type of differential protectionASensitivity30 mANumber2 PNumber of modules2Rated operating voltage Ue240 VInsulation voltage500 VImpact strength4,000 VFrequency50 HzTorque2.1NmTotal loss power at rated current1.9 WDevice life, electrical switching games2000Machine life mechanical switching games2000Connection cross section with flexible conductor1 - 16mm2Connection cross section for rigid conductor1 - 25mm2Operating temperature-25 to 40 °CStorage temperature-25 to 70 °CHeight installed product94 mmWide installed product35 mmDeep Installed Product68 mm
€107.82
Hager L76O load disconnector with fuses D02 63A 3pin+N DIN rail FI-Vorsicherung
Hager L76O load disconnector with fuses D02 63A 3pin+N DIN rail FI-Vorsicherung
2-5 days
D02 63A 3polig+N DIN rail FI-Vorsicherung D0-Safety load disconnector four-pole switch (3pin lockable) for D02 fuses according to OVE EN 60947-3, IEC 60947-3 400V~, 63A, for DIN rail mounting on one level lockable with other modular devices, since the same overall width. With alarm system for safety failure by LED. Screw capless plug-in technology offers permanent contact pressure on the factory. No contact relief during operation. Lockable with padlock and plombable. Removable safety plug with finger protection. For fitting with: D02 sleeve fit insert according to requirements and D0 fuse insert 1...63A Rated current: 63 A Number of poles: 3 P Shock voltage: 6 kV Rated operating voltage Ue: 400 V
€105.60
Hager EZN006 time relay,multifunction,1W,10A
Hager EZN006 time relay,multifunction,1W,10A
2-5 days
Frequency: 50/60 HzContact type: 1WContact Loading: AC1Max. bulb load: 450 WConnection type: screw technologyConnection cross-section with flexible conductor: 1 - 6mm2Connection cross section for rigid conductor: 1.5 - 10mm2Operating temperature: -20 to 50 °CStorage temperature: -40 to 70 °CNumber of modules: 1Protection type: IP40Assembly type: DIN rail (REG)
€103.75
Hager CEC463D FI switch 4P 63A 100mA type AC,AC
Hager CEC463D FI switch 4P 63A 100mA type AC,AC
Out-of-Stock
Nominal current: 63 ANumber of poles: 4 PSensitivity: 100 mAType of differential protection: ACImpact strength: 4 kVNumber of modules: 4AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50 HzTorque: 2,8NmConnection type: screw technologyTotal power loss under rated current: 12.5 WDevice life, electrical switching games: 2000Machine life mechanical switching games: 4000Connection cross-section with flexible conductor: 16mm2Connection cross section for rigid conductor: 25mm2Operating temperature: -5 to 40 °CStorage temperature: -55 to 70 °CHeight installed product: 83 mmWide installed product: 70 mmDeep installed product: 70 mm
Hager ADJ963D FI/LS 13A/1+N/C/30mA G/AC
Hager ADJ963D FI/LS 13A/1+N/C/30mA G/AC
2-5 days
1P+N 6kA C-13A 30mA AC-G typeRated current: 13 ATrigger characteristic: CNominal shutdown capacity: 6 kAType of differential protection: AC GSensitivity: 30 mANumber of poles: 2 PNumber of modules: 2AC voltage: 240 VInsulation voltage: 500 VImpact strength: 4000 VFrequency: 50 HzConnection type: screw technologyTorque: 2.1NmTotal loss power at rated current: 3.8 WDevice life, electrical switching games: 2000Machine life mechanical switching games: 2000Connection cross section for flexible conductor: 1 - 16mm2Connection cross section for rigid conductor: 1 - 25mm2Operating temperature: -5 to 40 °CStorage temperature: -25 to 70 °CHeight installed product: 83 mmWide installed product: 35 mmDeep installed product: 68 mm
€99.93
Hager ADJ966D FI/LS 16A/1+N/C/30mA G/AC
Hager ADJ966D FI/LS 16A/1+N/C/30mA G/AC
2-7 days
1P+N 6kA C-16A 30mA AC-G TypeRated current: 16 ATrigger characteristic: CNominal shutdown capacity: 6 kAType of differential protection: AC GSensitivity: 30 mANumber of poles: 2 PNumber of modules: 2AC voltage: 240 VInsulation voltage: 500 VImpact strength: 4000 VFrequency: 50 HzConnection type: screw technologyTorque: 2.1NmTotal loss power at rated current: 5.2 WDevice life, electrical switching games: 2000Machine life mechanical switching games: 2000Connection cross section for flexible conductor: 1 - 16mm2Connection cross section for rigid conductor: 1 - 25mm2Operating temperature: -5 to 40 °CStorage temperature: -25 to 70 °CHeight installed product: 83 mmWide installed product: 35 mmDeep installed product: 68 mm
€99.93
Hager VE118DN Vector Distribution IP65 18 PLE QC PE/N
Hager VE118DN Vector Distribution IP65 18 PLE QC PE/N
2-5 days
small distributor, vector, APV, IP65, 18PLE, with small distribution channel; Installation small plastic distributor, according to DIN VDE 0603 part 1, according to DIN 43871. For installation of devices up to 63 A according to standard DIN 43 880 with 70 mm or 85 mm installation depth, measuring voltage AC 400 V/50 Hz. Consisting of plastic base with galvanized steel profile rail, embossing for metric line insertion sleeves (top, bottom); lateral embossings for connecting sleeves for connecting two or more distributors side by side. Built-in PE/N clamps quick connector; Top with 46 mm slot. Clear view door front flush, right or left adjustable, lockable, distributor flangeable.Assembly type: plaster / construction Protection class: Protection class II Number of distribution rows: 1 Number of modules: 18
€98.41
Hager VH48AT Kleinverteiler HW,Volta,4x12(+2)TE,IP30,B314xH720xT87mm
On sale!
Hager VH48AT Kleinverteiler HW,Volta,4x12(+2)TE,IP30,B314xH720xT87mm
2-5 days



Assembly type:
hollow wall


Number of rows:
4


Width in division units:
12


Material of housing:
Plastic


Protection type (IP):
IP30


Height:
755 mm


Width:
348 mm


Depth:
94.5 mm


Installation depth:
94.5 mm


With transparent lid:
No


Access:
Yes


EMC version:
No


Color:
white


RAL number:
9010


€98.40
Hager ADS910D FI/LS 1P+N 6kA B-Charakteristik 10A 30mA
Hager ADS910D FI/LS 1P+N 6kA B-Characteristic 10A 30mA
2-5 days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 10 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 VRated current10 ATrigger characteristicBRated value6Type of differential protectionASensitivity30 mANumber2 PNumber of modules2Rated operating voltage Ue240 VInsulation voltage500 VImpact strength4,000 VFrequency50 HzTorque2.1NmTotal loss power at rated current3.4 WDevice life, electrical switching games2000Machine life mechanical switching games2000Connection cross section with flexible conductor1 - 16mm2Connection cross section for rigid conductor1 - 25mm2Operating temperature-25 to 40 °CStorage temperature-25 to 70 °CHeight installed product94 mmWide installed product35 mmDeep Installed Product68 mm
€97.97
Hager MCN640 LS switch 3P+N 6kA C-40A 4M cable protection switch 3 polig+N 6kA C-characteristics 40A 4 modules
Hager MCN640 LS switch 3P+N 6kA C-40A 4M cable protection switch 3 polig+N 6kA C-characteristics 40A 4 modules
2-5 days
Leitungsschutzschalter 3polig+N 6kA C-Charakteristik 40A 4 Module Leitungsschutzschalter nach DIN VDE 0641 Teil 11/8.92 , Beruehrungsschutz IP2x nach DIN VDE 0106 Teil 100 mit VDE Zeichen. LS mit zeitverzoegertem thermischen Ausloeser fuer Ueberlastschutz und elektromagnetischer Ausloeser fuer Kurzschlussschutz. Geeignet zum nachtraeglichen Anbau von Zusatzeinrichtungen. Beschriftungsmöglichkeit direkt am Gerät und Einzelentnahme aus dem Phasenschienenverbund durch Entriegelung der Hutschienenschnellbefestigung. Nennstrom: 40 A Auslösercharakteristik: C Nennabschaltvermögen: 6 kA Polanzahl: 4 P Anzahl Module: 4 Betriebsnennspannung Wechselstrom: 230/400 V Frequenz: 50/60 Hz Anschlussart: Schraubtechnik



Nennstrom:
40 A


Auslösercharakteristik:
C


Nennabschaltvermögen:
6 kA


Polanzahl:
4 P


Anzahl Module:
4


Betriebsnennspannung Wechselstrom:
230/400 V


Isolationsspannung:
500 V


Frequenz:
50/60 Hz


Anschlussart:
Schraubtechnik


Drehmoment:
2,8Nm


Gesamtverlustleistung unter Nennstrom:
16,9 W


Gerätelebensdauer, elektrische Schaltspiele:
4000


Gerätelebensdauer mechanische Schaltspiele:
20000


Betriebstemperatur:
-25 bis 60 °C


Lagerungstemperatur:
-25 bis 80 °C


Höhe installiertes Produkt:
83 mm


Breite installiertes Produkt:
70 mm


Tiefe installiertes Produkt:
70 mm


€96.43