List of products by brand Eaton

Eaton ZP-NHK Auslösesignalschalter schnappbar für PLS/PKN, 2W, 3A, 250VAC 248437
Eaton ZP-NHK trigger signal switch for PLS/PKN, 2W, 3A, 250VAC 248437
2-5 days
Design according to IEC/EN 62019, screwless assembly, subsequently snap-on to PLS and PKNM, ZP-IHK, ZP-WHK: additionally 1x husk pack can be snapped onto itself, specified minimum voltages apply per switching path. Attention in series circuits!, through contact material and construction especially suitable forSmall voltages, contact function with relative movement (self-cleaning contacts), ZP-NHK: Function of one of the two changer contacts switchable from “auxiliary switches” to “start signal switches”, trigger signal contact reports electrical triggering, test button for contact function “electr. Redemption’Accessories for FI/LS combination switchAccessories for circuit breakersBasic function AccessoriesTrigger signal contactApplicationSwitching devices for industrial and commercial applicationsProduct rangeAccessoriesAccessibilitymountable from left to right: LS, FI/LSuniversalAdditional equipmentSignal switchesPlant-mountednoConstruction width (TE)0.5Number of locks0Number of openers0Number of changers2Number of fault signal switches0Measurement switching currentA4Measurement voltageV250Type of voltageACWith autotest for fault current functionnoSuitable for max. Number of poles of the main contact unit (total)2Suitable for max. Current intensity of the main contact unitA4
€51.60
Eaton AFDD-16/2/B/003-A Brandschutzschalter, Fehlerlichtbogen-Schutzeinrichtung 187204
Eaton AFDD-16/2/B/003-A fire protection switch, fault arc protection device 187204
2-10 Tage
Basic function



Fire switch






Pole



2-pole



Trigger characteristic



B



Application



Switching devices for housing and purpose construction



Rated current

In
A
16



Measurement switching capacity according to IEC/EN 60898-1


:
10



Measurement switching capacity according to IEC/EN 61009


:
10



Measurement short-circuit strength

Ic)
:
10



Measurement error current

IBY DN
A
0,03 %



Type



Type A



Redemption


A
not delayed



Type of waste



ZV-SS



Product range



OFDD



Sensitivity



electrification



Impact resistance



conditional shock resistant 250 A




Technical data



Electric



Finished



IEC 62606IEC 61009



Current test marks



according to the following conditions:



Limits of operating voltage







Test circuit


BY AC
170 - 264



Sensitivity



electrification



Measurement short-circuit strength

Ic)
:
10



Life







electrical


Circuit games
4000



mechanical


Circuit games
20000


Mechanical



Cap dimensions


mm
45



Approval


mm
80



Installation width


mm
54 (3TH)



Assembly



Tristable locking slide allows removal from an existing composite.



Type of protection



IP20 switchIP40 installed



Clamps up and down



Mouth/Lift clamps



Clamp protection



Contact protection according to WBG4, ÖVE-EN 6



Material thickness


mm
0.8 - 2



permissible ambient temperature range


C
-25 - +40



permissible storage or. Transport temperature


C
-35 - +60



Climate resistance



in accordance with IEC/EN 61009



Contact position indicator



red / green


€137.94
Eaton AFDD-16/2/C/003-A Brandschutzschalter, Fehlerlichtbogen-Schutzeinrichtung 187210
Eaton AFDD-16/2/C/003-A fire protection switch, fault arc protection device 187210
2-10 Tage
Basic function







Fire switch










Pole



2-pole



Trigger characteristic



C



Application



Switching devices for housing and purpose construction



Rated current

In
A
16



Measurement switching capacity according to IEC/EN 60898-1


:
10



Measurement switching capacity according to IEC/EN 61009


:
10



Measurement short-circuit strength

Ic)
:
10



Measurement error current

IBY DN
A
0,03 %



Type



Type A



Redemption


A
not delayed



Type of waste



ZV-SS



Product range



OFDD



Sensitivity



electrification



Impact resistance



conditional shock resistant 250 A



Technical data



Electric



Finished



IEC 62606IEC 61009



Current test marks



according to the following conditions:



Limits of operating voltage







Test circuit


BY AC
170 - 264



Sensitivity



electrification



Measurement short-circuit strength

Ic)
:
10



Life







electrical


Circuit games
4000



mechanical


Circuit games
20000


Mechanical



Cap dimensions


mm
45



Approval


mm
80



Installation width


mm
54 (3TH)



Assembly



Tristable locking slide allows removal from an existing composite.



Type of protection



IP20 switchIP40 installed



Clamps up and down



Mouth/Lift clamps



Clamp protection



Contact protection according to WBG4, ÖVE-EN 6



Material thickness


mm
0.8 - 2



permissible ambient temperature range


C
-25 - +40



permissible storage or. Transport temperature


C
-35 - +60



Climate resistance



in accordance with IEC/EN 61009



Contact position indicator



red / green


€174.24
Eaton AFDD-13/2/C/003-A Brandschutzschalter, Fehlerlichtbogen-Schutzeinrichtung 187186
Eaton AFDD-13/2/C/003-A fire protection switch, fault arc protection device 187186
2-10 Tage
Basic function



Fire switch






Pole



2-pole



Trigger characteristic



C



Application



Switching devices for housing and purpose construction



Rated current

In
A
13



Measurement switching capacity according to IEC/EN 60898-1


:
10



Measurement switching capacity according to IEC/EN 61009


:
10



Measurement short-circuit strength

Ic)
:
10



Measurement error current

IBY DN
A
0,03 %



Type



Type A



Redemption


A
not delayed



Type of waste



ZV-SS



Product range



OFDD



Sensitivity



electrification



Impact resistance



conditional shock resistant 250 A




Technical data



Electric



Finished



IEC 62606IEC 61009



Current test marks



according to the following conditions:



Limits of operating voltage







Test circuit


BY AC
170 - 264



Sensitivity



electrification



Measurement short-circuit strength

Ic)
:
10



Life







electrical


Circuit games
4000



mechanical


Circuit games
20000


Mechanical



Cap dimensions


mm
45



Approval


mm
80



Installation width


mm
54 (3TH)



Assembly



Tristable locking slide allows removal from an existing composite.



Type of protection



IP20 switchIP40 installed



Clamps up and down



Mouth/Lift clamps



Clamp protection



Contact protection according to WBG4, ÖVE-EN 6



Material thickness


mm
0.8 - 2



permissible ambient temperature range


C
-25 - +40



permissible storage or. Transport temperature


C
-35 - +60



Climate resistance



in accordance with IEC/EN 61009



Contact position indicator



red / green


€174.24
Eaton M22-K10 Schliesser-Kontakt, Front 216376
Eaton M22-K10 Closer contact, front 216376
2-5 days
This article can also be used as a release auxiliary switch for the circuit breakers NZM.../NS... and the load disconnectors N.../PN....
€5.15
Eaton M22-K01 Oeffner-Kontakt, Front 216378
Eaton M22-K01 Open contact, front 216378
2-5 days
This article can also be used as a release auxiliary switch for the circuit breakers NZM.../NS... and the load disconnectors N.../PN....
€4.80
Eaton CSAU-01/01-10 UP-Schaltaktor 10A/230VAC 172937
Eaton CSAU-01/01-10 UP switch 10A/230VAC 172937
2-5 days
Switch actuator in small design 230VAC/10A. Easy to use with existing wall switches, control lights in staircases and corridors, direct light circuit with motion sensors and dawn switches. Compact design for the installation behind switches, buttons, motion sensors, wall sockets or in distribution boxes. Suitable for high switching power to switch a variety of loads such as lighting, ventilation, heating, etc.
€100.19