FI/LS switch

Hager ADA566D 1P+N 10kA C-16A 30mA Typ A
Hager ADA566D 1P+N 10kA C-16A 30mA Type A
2-5 days
1P+N 10kA C-16A 30mA Type A fault current circuit breaker according to DIN VDE 0664 Part 20 / EN61009-1 and DIN VDE 0664 Part 21 / EN61009-2-1. Contact protection according to DIN VDE 0660 part 514. Bi-Connect terminals below, blue test button and fault current display. Easy removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Rated current: 16 A Trigger characteristic: C Switching capacity Icn AC according to IEC 60898-1: 10 kA Type of fault current protection: A Rated fault current: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V
€66.53
Hager ADA563D FI/LS  1P+N 10kA C-13A 30mA Typ A
Hager ADA563D FI/LS 1P+N 10kA C-13A 30mA Type A
2-5 days
1P+N 10kA C-13A 30mA type A fault current circuit breaker according to EN 61009-1 and EN 61009-2-1. IP2x contact protection according to DIN VDE 0660 part 514. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, Bi-Connect terminals below, external blue test button for half-yearly actuation and fault current display. Easy removal from the phase rail composite. All products with VDE characters. Labeling option directly on the device. Rated current: 13 A Trigger characteristic: C Switching capacity Icn AC according to IEC 60898-1: 10 kA Type of fault current protection: A Rated fault current: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V
€66.53
Hager ADG516D FI/LS 1P+N 10kA B- 16A 30mA Typ A-G
Hager ADG516D FI/LS 1P+N 10kA B- 16A 30mA Type A-G
2-5 days
1P+N 10kA B- 16A 30mA type A-G fault current circuit breaker according to EN 61009-1 and EN 61009-2-1, short-term delayed according to ÖVE E 8601. IP2x contact protection according to DIN VDE 0660 part 514. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, Bi-Connect terminals below, external blue test button for half-yearly actuation and fault current display. Easy removal from the phase rail composite. All products with ÖVE characters. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: B Switching capacity Icn AC according to IEC 60898-1: 10 kA type of fault current protection: A G Rated fault current: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 230 V
€74.84
Hager ADA513D FI/LS 1P+N 10kA B-13A 30mA Typ A
Hager ADA513D FI/LS 1P+N 10kA B-13A 30mA Type A
2-5 days
1P+N 10kA B-13A 30mA type A fault current circuit breaker according to EN 61009-1 and EN 61009-2-1. IP2x contact protection according to DIN VDE 0660 part 514. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, Bi-Connect terminals below, external blue test button for half-yearly actuation and fault current display. Easy removal from the phase rail composite. All products with VDE characters. Labeling option directly on the device. Rated current: 13 A Trigger characteristic: B Switching capacity Icn AC according to IEC 60898-1: 10 kA Type of fault current protection: A Rated fault current: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V
€66.53
Hager ADG513D FI/LS 1P+N 10kA B- 13A 30mA Typ A-G
Hager ADG513D FI/LS 1P+N 10kA B- 13A 30mA Type A-G
2-5 days
1P+N 10kA B- 13A 30mA type A-G fault current circuit breaker according to EN 61009-1 and EN 61009-2-1, short-term delayed according to ÖVE E 8601. IP2x contact protection according to DIN VDE 0660 part 514. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, Bi-Connect terminals below, external blue test button for half-yearly actuation and fault current display. Easy removal from the phase rail composite. All products with ÖVE characters. Labeling option directly on the device. Nominal current: 13 A Trigger characteristic: B Switching capacity Icn AC according to IEC 60898-1: 10 kA type of fault current protection: A G Rated fault current: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 230 V
€74.84
Hager ADA516D Fehlerstrom-Leitungsschutzschalter 1P+N 10kA B-16A 30mA Typ A
Hager ADA516D fault current circuit breaker 1P+N 10kA B-16A 30mA Type A
2-5 days
1P+N 10kA B-16A 30mA Type A fault current circuit breaker according to EN 61009-1 and EN 61009-2-1. IP2x contact protection according to DIN VDE 0660 part 514. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, Bi-Connect terminals below, external blue test button for half-yearly actuation and fault current display. Easy removal from the phase rail composite. All products with VDE characters. Labeling option directly on the device. Rated current: 16 A Trigger characteristic: B Switching capacity Icn AC according to IEC 60898-1: 10 kA Type of fault current protection: A Rated fault current: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V
€62.37
Hager ADZ366D FI/LS 3X 1P+N 6kA C-Charakt. 16A 30mA Typ A QC
Hager ADZ366D FI/LS 3X 1P+N 6kA C character. 16A 30mA Type A QC
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with 3 x 1-pole circuit breaker for 230 V AC circuits and a fault current protection circuit in the compact housing. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 16 A and at the access up to 63 A, contact protection according to IP2x DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: C Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Number of modules: 4 Rated operating voltage Ue: 230 VRated current16 ATrigger characteristicCRated value6Type of differential protectionASensitivity30 mANumber4 PNumber of modules4Rated operating voltage Ue230 VInsulation voltage500 VFrequency50 HzTorque2NmTotal loss power at rated current10.9 WDevice life, electrical switching games2000Machine life mechanical switching games2000Operating temperature-5 to 40 °CStorage temperature-55 to 70 °CHeight installed product86 mmWide installed product71 mmDeep Installed Product70 mm
€124.50
Hager ADZ363D FI/LS 3X 1P+N 6kA C-Charakt. 13A 30mA Typ A QC
Hager ADZ363D FI/LS 3X 1P+N 6kA C character. 13A 30mA Type A QC
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with 3 x 1-pole circuit breaker for 230 V AC circuits and a fault current protection circuit in the compact housing. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 16 A and at the access up to 63 A, contact protection according to IP2x DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 13 A Trigger characteristic: C Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Number of modules: 4 Rated operating voltage Ue: 230 VRated current13 ATrigger characteristicCRated value6Type of differential protectionASensitivity30 mANumber4 PNumber of modules4Rated operating voltage Ue230 VInsulation voltage500 VFrequency50 HzTorque2NmTotal loss power at rated current9.6 WDevice life, electrical switching games2000Machine life mechanical switching games2000Operating temperature-5 to 40 °CStorage temperature-55 to 70 °CHeight installed product86 mmWide installed product71 mmDeep Installed Product70 mm
€124.50
Hager ADZ316D FI/LS 3X 1P+N 6kA B-Charakt. 16A 30mA Typ A QC
Hager ADZ316D FI/LS 3X 1P+N 6kA B character. 16A 30mA Type A QC
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with 3 x 1-pole circuit breaker for 230 V AC circuits and a fault current protection circuit in the compact housing. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 16 A and at the access up to 63 A, contact protection according to IP2x DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Number of modules: 4 Rated operating voltage Ue: 230 VRated current16 ATrigger characteristicBRated value6Type of differential protectionASensitivity30 mANumber4 PNumber of modules4Rated operating voltage Ue230 VInsulation voltage500 VFrequency50 HzTorque2NmTotal loss power at rated current10.9 WDevice life, electrical switching games2000Machine life mechanical switching games2000Operating temperature-5 to 40 °CStorage temperature-55 to 70 °CHeight installed product86 mmWide installed product71 mmDeep Installed Product70 mm
€124.51
Hager ADZ313D FI/LS 3X 1P+N 6kA B-Charakt. 13A 30mA Typ A QC
Hager ADZ313D FI/LS 3X 1P+N 6kA B character. 13A 30mA Type A QC
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with 3 x 1-pole circuit breaker for 230 V AC circuits and a fault current protection circuit in the compact housing. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 16 A and at the access up to 63 A, contact protection according to IP2x DIN VDE 0106 part 100, blue test button and fault current display. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 13 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 4 P Number of modules: 4 Rated operating voltage Ue: 230 VRated current13 ATrigger characteristicBRated value6Type of differential protectionASensitivity30 mANumber4 PNumber of modules4Rated operating voltage Ue230 VInsulation voltage500 VFrequency50 HzTorque2NmTotal loss power at rated current9.6 WDevice life, electrical switching games2000Machine life mechanical switching games2000Operating temperature-5 to 40 °CStorage temperature-55 to 70 °CHeight installed product86 mmWide installed product71 mmDeep Installed Product70 mm
€129.00
Hager ADS966D FI/LS 1P+N 6kA C-Charakteristik 16A 30mA
Hager ADS966D FI/LS 1P+N 6kA C-Characteristic 16A 30mA
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: C Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 VRated current16 ATrigger characteristicCRated value6Type of differential protectionASensitivity30 mANumber2 PNumber of modules2Rated operating voltage Ue240 VInsulation voltage500 VImpact strength4,000 VFrequency50 HzTorque2.1NmTotal loss power at rated current5.2 WDevice life, electrical switching games2000Machine life mechanical switching games2000Connection cross section with flexible conductor1 - 16mm2Connection cross section for rigid conductor1 - 25mm2Operating temperature-25 to 40 °CStorage temperature-25 to 70 °CHeight installed product94 mmWide installed product35 mmDeep Installed Product68 mm
€89.92
Hager ADS963D FI/LS 1P+N 6kA C-Charakteristik 13A 30mA
Hager ADS963D FI/LS 1P+N 6kA C-Characteristic 13A 30mA
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 13 A Trigger characteristic: C Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V Rated current13 ATrigger characteristicCRated value6Type of differential protectionASensitivity30 mANumber2 PNumber of modules2Rated operating voltage Ue240 VInsulation voltage500 VImpact strength4,000 VFrequency50 HzTorque2.1NmTotal loss power at rated current3.8 WDevice life, electrical switching games2000Machine life mechanical switching games2000Connection cross section with flexible conductor1 - 16mm2Connection cross section for rigid conductor1 - 25mm2Operating temperature-25 to 40 °CStorage temperature-25 to 70 °CHeight installed product94 mmWide installed product35 mmDeep Installed Product68 mm
€89.96
Hager ADS916D FI/LS 1P+N 6kA B-Charakteristik 16A 30mA
Hager ADS916D FI/LS 1P+N 6kA B-Characteristic 16A 30mA
3-8 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 VRated current16 ATrigger characteristicBRated value6Type of differential protectionASensitivity30 mANumber2 PNumber of modules2Rated operating voltage Ue240 VInsulation voltage500 VImpact strength4,000 VFrequency50 HzTorque2.1NmTotal loss power at rated current5.2 WDevice life, electrical switching games2000Machine life mechanical switching games2000Connection cross section with flexible conductor1 - 16mm2Connection cross section for rigid conductor1 - 25mm2Operating temperature-25 to 40 °CStorage temperature-25 to 70 °CHeight installed product94 mmWide installed product35 mmDeep Installed Product68 mm
€68.84
Hager ADS913D FI/LS 1P+N 6kA B-Charakteristik 13A 30mA
Hager ADS913D FI/LS 1P+N 6kA B-Characteristic 13A 30mA
2-5 days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 13 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 VRated current13 ATrigger characteristicBRated value6Type of differential protectionASensitivity30 mANumber2 PNumber of modules2Rated operating voltage Ue240 VInsulation voltage500 VImpact strength4,000 VFrequency50 HzTorque2.1NmTotal loss power at rated current3.8 WDevice life, electrical switching games2000Machine life mechanical switching games2000Connection cross section with flexible conductor1 - 16mm2Connection cross section for rigid conductor1 - 25mm2Operating temperature-25 to 40 °CStorage temperature-25 to 70 °CHeight installed product94 mmWide installed product35 mmDeep Installed Product68 mm
€89.17
Hager ADS910D FI/LS 1P+N 6kA B-Charakteristik 10A 30mA
Hager ADS910D FI/LS 1P+N 6kA B-Characteristic 10A 30mA
2-5 days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 10 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 VRated current10 ATrigger characteristicBRated value6Type of differential protectionASensitivity30 mANumber2 PNumber of modules2Rated operating voltage Ue240 VInsulation voltage500 VImpact strength4,000 VFrequency50 HzTorque2.1NmTotal loss power at rated current3.4 WDevice life, electrical switching games2000Machine life mechanical switching games2000Connection cross section with flexible conductor1 - 16mm2Connection cross section for rigid conductor1 - 25mm2Operating temperature-25 to 40 °CStorage temperature-25 to 70 °CHeight installed product94 mmWide installed product35 mmDeep Installed Product68 mm
€97.97