List of products by brand Eaton

Eaton SPCT2-335-3+NPE/BB surge arrester 3+N/BB 335VAC 3x20KA 167630
2-7 days
Design of poles3 + N / PRated leakage current (8/20)KA20Rated voltage ACV335Rated voltage DCV0Maximum permanent voltage ACV335Highest continuous voltage DCV0Max. PV voltageV0Protection levelKV1.6Protection level L-NKV0Protection level N-PEKV0Short circuitnoAssembly typeHat rail 35 mmSize4 THEMax. Conductor cross-section rigid (one/multiple)mm225Max. Conductor cross section flexible (fine)mm20With telecommunication contactnoIntegrated PreservationnoSignaling on the deviceopticalTest class type 2yesType of protection (IP)IP20
€177.60
Eaton Z-SLS/NEOZ/3 NEOZED charge switch D02/D01 63A 3P 4.5TE 248234
2-5 days
Safety load disconnector, rated operating voltage 230/400 VAC, 1-pin 110 VDC, 2-pin 220 VDC, suitable for melting inserts with operating class gG (gL) , aM, current encoding by safety set, plombable, feeding on both sides possible, screw capless plug-in technology, suitable for fuses D01: 1, 2, 4, 6, 10, 16A, D02: 2047
€68.24
Eaton PKNM-13/1N/B/003-A-MW FI-LS 13A/1-pol+N/B/30mA A 236133
2-5 days
High-quality fault current protection switches/control protection switches Combination without voltage, contact position indicator red - green, clamping aid - back plug protection, tristable snap-in slides - enables expansion from an existing interlocking system, peripheral accessory program to be retrofitted, large selection of dimension fault currents, dimensioning currents up to 40 A, triggering characteristics B, C, dimensioning switching capacity 10 kA, suitable for use in outdoor air distribution (convection)
€87.12
Eaton PKNM-13/1N/C/003-A-MW FI/LS switch A 13A/1+N/C 30mA 250A 236145
2-5 days




Polzahl (gesamt)

 
 
2



Anzahl der abgesicherten Pole

 
 
1



Bemessungsspannung

 
V
230



Bemessungsstrom

 
A
13



Bemessungsfehlerstrom

 
A
0.03



Fehlerstrom-Typ

 
 
A



Energiebegrenzungsklasse

 
 
3



Bemessungsabschaltvermögen nach EN 60898

 
kA
10



Bemessungsabschaltvermögen nach IEC 60947-2

 
kA
0



Frequenz

 
 
50 Hz



Auslösecharakteristik

 
 
C



Mitschaltender Neutralleiter

 
 
ja



Überspannungskategorie

 
 
3



Verschmutzungsgrad

 
 
2



Breite in Teilungseinheiten

 
 
2



Einbautiefe

 
mm
70



Geeignet für Unterputz-Installation

 
 
nein



Schutzart (IP)

 
 
IP20



Stoßstromfestigkeit

 
kA
0.25



Spannungsart

 
 
AC



Fehlauslöseschutz

 
 
nein


€74.05
Eaton PLSM-B25-MW LS switch 25A/1pol/B 242182
2-5 days
Trigger characteristicBNumber of poles (total)1Number of secured poles1Rated currentA25Measurement voltageV230Measurement switching capacity Icn according to EN 60898 at 230 VKA10Measurement switching capacity Icn according to EN 60898 at 400 VKA10Measurement switching capacity Icu according to IEC 60947-2 at 230 VKA0Measurement switching capacity Icu according to IEC 60947-2 at 400 VKA0Type of voltageACEnergy limiting class3FrequencyHZ50 to 60Interconnecting neutral conductornoSuitable for underground installationnoOvervoltage category3Pollution2Width in division units1Installation depthmmANNEXAdditional equipment possibleyesType of protection (IP)IP20
€11.04
Eaton BC-A-3/39-A small scale 3 row, without door, without rear wall B250xH475xT94mm 101556
2-5 days
Upput small distributor, protection class I, Scope of delivery: case, device carrier, zero and protective conductor terminals with clamp carrier, assembly instructions, labeling arcAssembly typeStructureNumber of rows3Width in division units13Type of coveroptionalExhaustwith necklineTransparent lid/doornoMaterial of the housingPlasticHeightmm475Widthmm250Depthmm94Installation depthmm46Internal depthmm72DIN railyesWith mounting platenoAccessibilitynoEMC versionnoColourwhiteRAL number9010Type of protection (IP)IP30With lockno
€43.80
Eaton PLSM-B20-MW LS switch 20A/1pol/B 242181
2-5 days
Trigger characteristicBNumber of poles (total)1Number of secured poles1Rated currentA20Measurement voltageV230Measurement switching capacity Icn according to EN 60898 at 230 VKA10Measurement switching capacity Icn according to EN 60898 at 400 VKA10Measurement switching capacity Icu according to IEC 60947-2 at 230 VKA0Measurement switching capacity Icu according to IEC 60947-2 at 400 VKA0Type of voltageACEnergy limiting class3FrequencyHZ50 to 60Interconnecting neutral conductornoSuitable for underground installationnoOvervoltage category3Pollution2Width in division units1Installation depthmmANNEXAdditional equipment possibleyesType of protection (IP)IP20
€11.86
Eaton PFIM-40/2/003-G/A FI switch, 40A, 2p, 30mA, type G/A 108045
2-9 days
Number2Measurement voltageV230Rated currentA40Measurement error currentA0.03Assembly typeDIN railError current typeASelective typenoShort-circuit strength (Icw)KA10Impact resistanceKA3Frequency50 HzAdditional equipment possibleyesType of protection (IP)IP20Size (according to DIN 43880)1Width in division units2Installation depthmmANNEXShort-term delayed typeyes
€183.44