List of products by brand Legrand

Legrand 411785 TX3 40A, 4-pin, 300mA, type A, 400VAC, 4TE
2-7 days
Legrand Safety circuit breakers TX3, type A, for alternating and pulsating direct fault currents according to VDE 0664-10, EN 61008-1, undelayed, 4-pin, rated current In 40 A, rated fault current Idn 300 mA, rated voltage Un 400 VAC, rated frequency 50 Hz, shock voltage up to 250 A, rated short circuit breakers 10 kA.
€77.60
Legrand 403358 TX3 B-Characteristic circuit breaker, 20A, 1-pole, 6kA, 230/400VAC, 1TE
2-7 days
Legrand Safety switch TX3 according to EN 60898-1, VDE 0641-11, EN 60947-2, 1-pole, B-characteristics, Rated current In 20 A, Rated switching capacity Icn 6 kA according to EN 60898-1, Rated voltage Un 230/400 VAC, Rated frequency 50/60 Hz, Energy limiting class 3, Mounting on hat profile rail EN 60715. Circuit breakers with B-characteristics are primarily designed for line protection in light and socket circuits.
€9.41
Legrand 403359 TX3 Circuit breaker B-Characteristic, 25A, 1-pole, 6kA, 230/400VAC, 1TE
2-7 days
Legrand Safety switch TX3 according to EN 60898-1, VDE 0641-11, EN 60947-2, 1-pole, B-characteristics, Rated current In 25 A, Rated switching capacity Icn 6 kA according to EN 60898-1, Rated voltage Un 230/400 VAC, Rated frequency 50/60 Hz, Energy limiting class 3, Mounting on hat profile rail EN 60715. Circuit breakers with B-characteristics are primarily designed for line protection in light and socket circuits.
€9.41
Legrand 403360 TX3 Circuit breaker B-Characteristic, 32A, 1-pole, 6kA, 230/400VAC, 1TE
2-7 days
Legrand Safety circuit breakers TX3 according to EN 60898-1, VDE 0641-11, EN 60947-2, 1-pole, B-characteristics, Rated current In 32 A, Rated switching capacity Icn 6 kA according to EN 60898-1, Rated voltage Un 230/400 VAC, Rated frequency 50/60 Hz, Energy limiting class 3, Mounting on hat profile rail EN 60715. Circuit breakers with B-characteristics are primarily designed for line protection in light and socket circuits.
€9.41
Legrand 404169 TX3 C-characteristic circuit breaker, 10A, 1-pole, 10kA,230/400VAC, 1TE
2-7 days
Legrand Safety switch TX3 according to EN 60898-1, VDE 0641-11, EN 60947-2, 1-pole, C-characteristics, Rated current In 10 A, Rated switching capacity Icn 10 kA according to EN 60898-1, Rated voltage Un 230/400 VAC, Rated frequency 50/60 Hz, Energy limiting class 3, Mounting on hat profile rail EN 60715. Circuit protection switches with C-characteristics are provided for line protection in devices with high switch-on currents (e.g. motors and transformers).
€9.88
Legrand 411311 DX3 FI/LS switch C-characteristic, 13A, 1P+N, 10kA, 30mA, type F-G, 230VAC, 2TE
2-7 days
Legrand FI/LS switch DX3, 1-pole with switching neutral conductor, type F-G, mixing frequency sensitive according to EN 62423, EN 61009-1, VDE 0664-20, G according to ÖVE E8601, short-term delayed, at least 10 ms, measuring current In 13 A, measuring error current Idn 30 mA.C characteristic. Fastening to DIN profile rail EN 60715 by latching quick fixes, clear information on the front of each device, unambiguous switching position indicator red/green on switching lever (lockable), with labeling window, with undercut protection for safe insertion of the conductor into elevator terminal, attachment of auxiliary devices possible.
€129.33
Legrand 403432 TX3 C-characteristic circuit breaker, 10A, 1-pole, 6kA, 230/400VAC, 1TE
2-7 Tage
Legrand Safety circuit breakers TX3 according to EN 60898-1, VDE 0641-11, EN 60947-2, 1-pole, C-characteristics, Rated current In 10 A, Rated switching capacity Icn 6 kA according to EN 60898-1, Rated voltage Un 230/400 VAC, Rated frequency 50/60 Hz, Energy limiting class 3, Mounting on hat profile rail EN 60715. Circuit protection switches with C-characteristics are provided for line protection in devices with high switch-on currents (e.g. motors and transformers).
€14.11
Legrand 403435 TX3 Circuit breaker C-Characteristic, 20A, 1-pole, 6kA, 230/400VAC, 1TE
2-7 days
Legrand Safety circuit breakers TX3 according to EN 60898-1, VDE 0641-11, EN 60947-2, 1-pole, C-characteristics, Rated current In 20 A, Rated switching capacity Icn 6 kA according to EN 60898-1, Rated voltage Un 230/400 VAC, Rated frequency 50/60 Hz, Energy limiting class 3, Mounting on hat profile rail EN 60715. Circuit protection switches with C-characteristics are provided for line protection in devices with high switch-on currents (e.g. motors and transformers).
€14.11
Legrand 403436 TX3 C-characteristic circuit breaker, 25A, 1-pole, 6kA, 230/400VAC, 1TE
2-7 days
Legrand Safety switch TX3 according to EN 60898-1, VDE 0641-11, EN 60947-2, 1-pole, C-characteristics, Rated current In 25 A, Rated switching capacity Icn 6 kA according to EN 60898-1, Rated voltage Un 230/400 VAC, Rated frequency 50/60 Hz, Energy limiting class 3, Mounting on hat profile rail EN 60715. Circuit protection switches with C-characteristics are provided for line protection in devices with high switch-on currents (e.g. motors and transformers).
€14.11
Legrand 403437 TX3 C-characteristic circuit breaker, 32A, 1-pole, 6kA, 230/400VAC, 1TE
2-7 days
Legrand Safety circuit breakers TX3 according to EN 60898-1, VDE 0641-11, EN 60947-2, 1-pole, C-characteristics, Rated current In 32 A, Rated switching capacity Icn 6 kA according to EN 60898-1, Rated voltage Un 230/400 VAC, Rated frequency 50/60 Hz, Energy limiting class 3, Mounting on hat profile rail EN 60715. Circuit protection switches with C-characteristics are provided for line protection in devices with high switch-on currents (e.g. motors and transformers).
€14.11
Legrand 404081 TX3 Circuit breaker B-Characteristic, 6A, 1-pole, 10kA,230/400VAC, 1TE
2-7 days
Legrand Safety switch TX3 according to EN 60898-1, VDE 0641-11, EN 60947-2, 1-pole, B-characteristics, Rated current In 6 A, Rated switching capacity Icn 10 kA according to EN 60898-1, Rated voltage Un 230/400 VAC, Rated frequency 50/60 Hz, Energy limiting class 3, Mounting on hat profile rail EN 60715. Circuit breakers with B-characteristics are primarily designed for line protection in light and socket circuits.
€14.11
Legrand 404167 TX3 C-characteristic circuit breaker, 6A, 1-pole, 10kA,230/400VAC, 1TE
2-7 days
Legrand Safety switch TX3 according to EN 60898-1, VDE 0641-11, EN 60947-2, 1-pole, C-characteristics, Rated current In 6 A, Rated switching capacity Icn 10 kA according to EN 60898-1, Rated voltage Un 230/400 VAC, Rated frequency 50/60 Hz, Energy limiting class 3, Mounting on hat profile rail EN 60715. Circuit protection switches with C-characteristics are provided for line protection in devices with high switch-on currents (e.g. motors and transformers).
€14.11