List of products by brand Eltako

Eltako FUD14 RS485 bus actuator universal dimming.
Eltako FUD14 RS485 bus actuator universal dimming.
3-10 days
Universal dimmor for mounting on support rail DIN-EN 60715 TH35, Power MOSFET up to 400 W or. 800 W, automatic lamp detection, bidirectional, stand-by loss only 0.3 Watt, minimum brightness and dimming speed adjustable, with children's room, slumber and light alarm circuit, in addition with light scene control and constant light control, no minimum load, connection to the RS485 interface universal dimming switch, power MOSFET up to 400W. Automatic lamp detection. Bidirectional. Stand-by loss only 0.3 Watt. Minimum brightness and dimming speed adjustable. With children's room, slumber and light alarm. In addition to light scene control and constant light control. Row mounting device for mounting on support rail. Universal dimming switch for lamps up to 400W, depending on the ventilation conditions, dimmable energy saving lamps ESL and dimmable 230V LED lamps additionally depending on the lamp electronics. Switching in the zero passage with soft-on and soft-out for lamp protection. Switching voltage 230V. No minimum load required. The set brightness level remains stored when switching off (memory). In the event of a power failure, the switching position and the brightness stage are stored and is switched on when the supply voltage is returned. Automatic electronic overload protection and overtemperature shutdown. Connection to Eltako-RS485-Bus. Cross-wiring bus and power supply with plug-in bridge. The upper rotary switch LA/LRN is first required for learning and determines during operation whether the automatic lamp recognition should act or special comfort positions. The LED accompanies the learning process according to the user manual and displays control commands by short flashing. Width in division units: 1 Number of outputs: 1 Output power from/to: 400 - W Voltage range: 230 - V Version: Dimmaktor Power added: No Bus system EIB/KNX: No Bus system Radiobus:
€82.08
Eltako FR12-230V
Eltako FR12-230V
3-10 days
Field-free switch Self-learning field-free switch, interrupts the power supply after all downstream consumers and thus prevents disturbing electromagnetic fields, self-learning processor instead of setting buttons for the current thresholds, rated switching power 16 A/250 W AC self-learning field-free switch. Self-learning. Stand-by-loss only 0.8 Watt. Modern hybrid technology combines the advantages of wear-free electronic control with high switching power from special relays. The field-free switch interrupts the power supply after disconnection of downstream consumers and thus prevents interfering electromagnetic fields. Up to a current consumption of 200ma, small consumers are allowed which do not prevent field-free switching after larger consumers are switched off. The limit value does not have to be adjusted manually, but is learned by the FR12 using a patented method. Consumers with more than 200ma current consumption are always defined as consumers which are intended to cause the power supply to be switched on. As long as no larger consumer is switched on, the monitored circuit 1-pole remains switched off from the network. Neutral and protective conductors are not switched to prevent an antenna effect. An adjustable DC voltage with low residual ripple is present for monitoring. Therefore, a bridging of the working contact is not permissible and leads to destruction of the device. When a consumer is switched on, the field-free switch switches the monitored outer conductor with a delay of approx. 1 second and the LED lights red. Measurement voltage: 230 W
€78.70
Eltako FSM61-UC Radio transmitter module
Eltako FSM61-UC Radio transmitter module
3-10 days
Radio transmitter module for installation, radio 2x transmitter module with internal antenna, no stand-by loss radio 2x transmitter module. With internal antenna. No standby loss. For installation. 45mm long, 45mm wide, 18mm deep. The radio transmitter module FSM61-UC has two channels and can thus be radio telegrams in the Eltako- Send building radio. A1 causes a radio telegram, such as rocker, to press a radio button with a rocker and A3 like rocker at the bottom. The telegram when opening the two control contacts is identical to that of the radio button. Several radio transmission modules must not be simultaneously controlled. The universal control voltage at +An/-A2 processes control commands from 8 to 253V AC or 10 to 230V DC with a length of at least 0.2 seconds. Maximum parallel capacity of the control lines at 230V 5nF. This corresponds to a length of about 20 meters. If the terminals A1 and A3 are connected to a bridge, a spark telegram of A3 is transmitted 1× per minute as long as the control voltage is applied. For example, for central commands with priority. No constant power supply required, therefore no stand-by loss. The rotary switch is used for activation or. Deactivation of the encryption is required and is in operation on AUTO. Enable encryption: Turn the rotary switch to right stop (position key) and once buttons. Disable encryption: Turn the rotary switch to left stop (position of broken key) and once buttons. Number of commands: 2 Rolling code system: No Radio hand transmitter: No Radio button under plaster: No Radio button on plaster: No Radio coder: Yes Keyboard protection cover: No
€77.71
Eltako FGW14 RS485-Bus gateway
Eltako FGW14 RS485-Bus gateway
3-10 days
Bus gateway multiple gateway, bidirectional, stand-by-loss only 0.5 watts, for coupling in up to 3 FEM, up to 10 FTS12EM, for direct connection with the computer GFVS-Safe, for connection with the bus components of the series 12, an RS232 interface or as a bus connector of two RS485 buses of the series 14, connection to the Eltako-RS485 bus, cross wiring bus and power supply with multiple gateway. Bidirectional. Stand-by loss only 0.5 Watt. Row mounting device for mounting on support rail. The gateway is only 1 TE wide but can be used multiple times: for coupling up to three radio reception modules, for direct connection via the RS232 interface to the PC, for connection with the bus components of the older series 12 or as a bus connector of two RS485 buses of the series 14. Connection to Eltako-RS485-Bus. Cross-wiring bus and power supply with plug-in bridge. The hold terminal is connected to the FAM14 or FTS14KS. Radio reception modules are connected in parallel to the sub-bus terminals RSA2 and RSB2 as well as the power supply terminals GND and +12V. Up to 10 probe input modules FTS12EM are optionally connected in series to the sub-bus terminals RSA2 and RSB2, possibly in series with radio reception modules FEM. The PC connection is effected by connection to the terminals Tx and Rx. Series 12 actuators are connected to the RSA2 and RSB2 sub-bus terminals. There is no hold connection here. A second series 14-bus is fed via the terminals RSA2/RSB2. The settings of the operating mode rotary switch BA take place according to the operating instructions. TLE: 1
€76.51
Eltako S2U12DDX-UC 2-channel clock
Eltako S2U12DDX-UC 2-channel clock
3-10 days
2-channel weekly switch clock 1+1 closer potential-free 16A/250V AC, 60 switch clock memory locations, power reserve 2 weeks, stand-by loss max. 0.4 Watt, automatic summer winter time switch and pulsed, with astro function, additional control input for the central on or off 2-channel clock with astro function. Stand-by loss only 0.03-0.4 watts. To this end, simply connect the N conductor to the terminal (N) and L to 1(L) and/or 3(L). This results in an additional stand-by loss of only 0.1 Watt. Due to the use of bistable relays, there is no coil loss power and no heating thereby even in the switched-on state. Up to 60 switching clock memory locations are distributed freely on the channels. With date and automatic summer/winter time conversion. Power reserve without battery about 7 days. Each storage space can be occupied either with the astro function (automatic switching after sunrise or sunset), the switch-on and switch-off time or a pulse switching time (in which a pulse of 2 seconds is triggered). The switch-on or switch-off time Astro can be shifted ± 2 hours and, in addition, from the manufacturing week 19/2012, a time shift of up to ± 2 hours influenced by the sun. With control input +(A1) for central control ON or OFF with priority. Supply voltage and control voltage for central control 8..230V UC. The switching clock is set with the MODE and SET keys and a key lock is possible. Set language: After each application of the supply voltage, the language can be selected with SET within 10 seconds and confirmed with MODE. D = German, GB = English, F = French, IT = Italian and ES = Spanish. Then the normal display appears: weekday, time, day and month. Quick run: In the following settings, the numbers run quickly when the input key is pressed longer
€76.07
Eltako FTS14EM Sensor input module for RS485 bus
Eltako FTS14EM Sensor input module for RS485 bus
3-10 days
Sensor input module for mounting on support rail DIN-EN 60715 TH35, for the Eltako-RS485-Bus, 10 control inputs for universal control voltage, stand-by loss only 0.1 W, connection to the Eltako-RS485 bus, cross-switching bus and power supply with plug-in bridges, the 12V DC power supply takes place with the only 1 TE wide switching power supply FSNT14-12V/12W, 10 control inputs +E1..+E10/-E galvanically isolated from the supply voltage, control voltage: 8..230V UC TLE: 2 Number of operating points: 10 input module for the Eltako-RS485-Bus, 10 control inputs for universal control voltage. Stand-by loss only 0.1 Watt. Connection to Eltako-RS485-Bus. Cross-wiring bus and power supply with plug-in bridges. Operation in conjunction with FAM14 or FTS14KS. 10 control inputs +E1..+E10/-E galvanically separated from the supply voltage. Control voltage: 8..230V UC. From the production week 44/15, the control inputs can be activated either for probes (delivery state), window door contacts or motion detectors. Control inputs for probes: Telegrams are generated by radio scanners (e.g. 0x70). Maximum 10 FTS14EM form a group. In total, a maximum of 50 FTS14EM is possible with 500 probes or contacts in an RS485 bus. In order to generate the necessary learning messages for learning into the actuators, the desired group must be selected at the upper and lower rotary switches. For probes in the region UT or RT or for window door contacts and motion detectors in the region RT.
€76.07
Eltako TF61J-230V Tip-Funk® blind actuator
Eltako TF61J-230V Tip-Funk® blind actuator
3-10 days
Radio blind actuator Tip-Funk® blind and roller shutter actuator, 1+1 closer, 4 A/250 W AC, for a shading element motor. 45 x 45 x 18 mm, stand-by loss only 0.8 W, up to 24 radio universal probes, radio direction probes and radio central control probes as well as bidirectional radio can be learned with the comfortable tip-radio technique, in addition, the actuator can be locally controlled with a conventional 230 V control probe without glow lamp current. 45x45x18mm. Stand-by loss only 0.8 Watt. With the comfortable Tip-Funk® technology, up to 24 radio universal probes, radio direction probes and radio central control probes can be learned. In addition, the actuator can be locally controlled with a conventional 230V controller without a glow lamp current. H x B x T mm: 45 x 45 x 18 Rated voltage: 250 W
€75.41
Eltako WSZ15D-32A MID AC counter MID ge
Eltako WSZ15D-32A MID AC counter MID ge
3-10 days
Electronic AC meter for mounting on support rail DIN-EN 60715 TH35, maximum current 32A, stand-by loss only 0.4 Watt, accuracy class B (1)%, with SO interface TLE: 1 current A: 5(32) Certified: MID calibrated tariff version of the electricity meter: tariff
€74.42
Eltako DTD65-230V-wg Rotary key switch
Eltako DTD65-230V-wg Rotary key switch
3-10 days
Rotary-Tast Dimming Switch for Single Mount 84x84x25mm or assembly into the E-Design switch system. Installation depth 33 mm. Universal dimming switch with rotary knob, Power MOSFET up to 300W. Automatic lamp detection. Minimum brightness and maximum brightness adjustable. Stand-by loss only 0.14 Watt. Universal dimming switch for lamps up to 300W, depending on the ventilation conditions. Dimmable energy-saving lamps ESL and dimmable 230V LED lamps additionally depend on lamp electronics. Switching in the zero passage with soft-on and soft-out for lamp protection. Supply, switching and control voltage 230V. No minimum load required. The set brightness level remains stored when switching off (memory). In the event of a power failure, the switching position and the brightness stage are stored and is switched on when the supply voltage is returned. Automatic electronic overload protection and overtemperature shutdown. Mounting: Mounting plate on. After adjusting the rotary switches, remove the red insulating cap and plug the rotary knob. The insulating cap should remain in the DTD65 for later use. Then snap the frame and plug the front panel. Attention! Before assembly and disassembly always turn off the mains voltage! With the left %-Drehschalter the minimum brightness (fully dimmed) can be set. With the middle %-Drehschalter the maximum brightness (fully dimmed) can be set. The right rotary switch adjusts the operating mode: AUTO allows the dimming of all lamp types. LC is a comfort position for LED lamps, which cannot be dimmed far enough on AUTO (phase section) due to construction and must therefore be forced to phase out. EC is a comfort position for energy-saving lamps, which must be switched on with an increased voltage due to the construction, so that they can also be switched on safely again cold. Operation: In the center of rotation
€74.42
Eltako DTD55-230V-wg rotary push-pull switch
Eltako DTD55-230V-wg rotary push-pull switch
3-10 days
Mounting type: brushing Color: white Operation type: rotary/printing knob Halogen-free: Yes Composition: other load type: universal Serial dimmer: No Conveyor input: No Luminous accumulator: Yes Applicable with button: Yes Applicable with motion detector: No Applicable with presence detector: No Applicable with time switch/timer: No Applicable with radio button: No 80x80x25mm or installation in the FT55 switch system. Installation depth 33mm. Universal dimming switch with rotary knob, Power MOSFET up to 300W. Automatic lamp detection. Minimum brightness and maximum brightness adjustable. Stand-by loss only 0.14 Watt. Universal dimming switch for lamps up to 300W, depending on the ventilation conditions. Dimmable energy-saving lamps ESL and dimmable 230V LED lamps additionally depend on lamp electronics. Switching in the zero passage with soft-on and soft-out for lamp protection. Supply, switching and control voltage 230V. No minimum load required. The set brightness level remains stored when switching off (memory). In the event of a power failure, the switching position and the brightness stage are stored and is switched on when the supply voltage is returned. Automatic electronic overload protection and overtemperature shutdown. Mounting: Mounting plate on. After adjusting the rotary switches, remove the red insulating cap and plug the rotary knob. The insulating cap should remain in the DTD55 for later use. Then snap the frame and plug the front panel. Attention! Before assembly and disassembly always turn off the mains voltage! With the left %-Drehschalter the minimum brightness (fully dimmed) can be set. With the middle %-Drehschalter the maximum
€74.42
Eltako FRP61-230V Radio Repeater
Eltako FRP61-230V Radio Repeater
3-10 days
Radio repeater for installation and AP installation, this repeater is only required if the structural conditions prevent an undisturbed reception or the distance between radio probe and receiver is too large, from work the 1-level mode is activated but also can be adjusted to level 2, radio repeater need not be learned, they receive and amplify the signals from all radio sensors in their reception area, only supply voltage required, standby level 1. Stand-by loss only 0.9 Watt. For installation. 45mm long, 45mm wide, 33mm deep. This repeater is only required if the structural conditions prevent an undisturbed reception, or the distance between radio button and receiver is too large. The 1-level mode is set from work. Only the radio signals are received, tested and transmitted with full transmission power. Radio signals from other repeaters are ignored to reduce the amount of data. The rotary switch can be switched to the 2-level mode. In addition to the radio signals from sensors, the radio signals from another 1-level repeater are also processed. A radio signal can thus be received and amplified at most twice. The LED displays incoming radio signals by short flashing. Radio-repeaters do not have to be learned. They receive and amplify the radio signals from all radio sensors in their reception area.
€72.14
Eltako FSR14-2x RS485-Bus actuator 2-channel
Eltako FSR14-2x RS485-Bus actuator 2-channel
3-10 days
Electric shock switch relays for mounting on support rail DIN-EN 60715 TH35, 16 A/250 V AC, potential-separated from supply voltage, with DX technology, bidirectional, stand-by-loss only 0.1 Watt power surge switch relays with 2 channels, 1+1 lock potential-free 16A/250V AC, light bulbs 2000W, with DX technology. Bidirectional. Stand-by loss only 0.1 Watt. Row mounting device for mounting on support rail. Connection to Eltako-RS485-Bus. Cross-wiring bus and power supply with plug-in bridge. To this end, simply connect the N conductor to the terminal (N1) and L to 1(L) and/or N to (N2) and L to 3(L). This results in an additional stand-by loss of only 0.1 Watt. If the supply voltage fails, the switching state is maintained. When the supply voltage is recurring, it is switched off in a defined manner. The channels can be taught independently as ES and/or ER channels. Scene control: A plurality of channels of one or more FSR14-2x to one scene can be switched on or off with one of the four control signals of a pushbutton learned as a scene scanner. Central commands on the PC are sent with the building radio visualization and control software GFVS. The LED under the upper rotary switch accompanies the learning process according to the user manual and displays control commands during operation by short flashing. Max. switching current: 16 A Max. Switching power: 2000 W Width in division units: 1 Max. Number of switching outputs: 2 Bus system EIB/KNX: No Bus system Funkbus: Yes Bus system Powernet: No Bus connection included: Yes Bus system LON: No On site/hand operation: Yes With LED indicator: No Different phases connectable: No Modular expansion option: No
€72.14
Eltako EUD12D-UC power surge dimming switch
Eltako EUD12D-UC power surge dimming switch
3-10 days
Universal Bus Dimming Switch for mounting on DIN-EN 60715 TH35 Power MOSFET up to 400 W, for lamps up to 400 W, depending on the ventilation conditions, dimmable energy saving lamps ESL and dimmable 230 V-LED lamps additionally depending on the lamp electronics, automatic lamp detection, minimum or maximum brightness and dimming speed adjustable, children's room and slumber circuit width. Stand-by loss only 0.3 Watt. Minimum brightness, maximum brightness and dimming speed adjustable. With children's room and slumber circuit. 1 division unit. Universal dimming switch for lamps up to 400W, depending on the ventilation conditions. Dimmable energy-saving lamps and dimmable 230V LED lamps additionally depend on lamp electronics. Up to 3600W with power inputs at terminals X1 and X2. The control inputs are galvanically separated from the supply and switching voltage. Switching in the zero passage with soft-on and soft-out for lamp protection. In the event of a power failure, the switching position and the brightness stage are stored and is switched on when the supply voltage is returned. From 110W control voltage glow lamp current 5ma (not at RTD). Automatic electronic overload protection and overtemperature shutdown. The functions and times are entered according to the user manual with the MODE and SET keys and displayed on the LC display. A key lock is possible.
€71.69
Eltako FSB14 RS485 bus actuator
Eltako FSB14 RS485 bus actuator
3-10 days
Radio switch for mounting on support rail DIN-EN 60715 TH35, for shading elements and roller shutters, 2 channels for 2 230 V motors, 2+2 closer 4A/250 V AC, potential-separated from supply voltage 12 V, bidirectional, stand-by-loss only 0.1 Watt, connection to the supply voltage 12 V Eltako-RS485 bus, the probes can be learned either as a direction sensor or as a universal probe PLE: 1 Max. Number of blind exits: 2 Bus system EIB/KNX: No Bus system Radiobus: Yes Bus system Powernet: No Bus connection included: Yes Bus system LON: No On site/hand operation: Yes With LED display: No Switch actuator shading elements and roller shutters with 2 channels for two 230V motors. 2+2 Locker 4A/250V AC, potential-separated from the supply voltage 12V. Bidirectional. Stand-by loss only 0.1 Watt. Row mounting device for mounting on support rail. Connection to Eltako-RS485-Bus. Cross-wiring bus and power supply with plug-in bridge. Contact circuit in the zero passage for protecting the contacts and motors. A motor is connected to 1, 2 and N, a second motor may be connected to 3, 4 and N. If both relays of the FSB14 are switched on, 0.4 Watt are required. If the supply voltage fails, it is switched off in a defined manner. The probes can be learned either as a directional sensor or as a universal probe: Local control with universal probe: With each pulse, the switching position changes in the order, stop, stop, stop. Local control with directional sensor: The switching position on is activated in a targeted manner with a key pulse at the top. On the other hand, the switching position Ab is selectively activated by means of a pulse at the bottom. Another pulse from one of the two probes immediately interrupts the sequence. Central control dynamic without priority: By means of a control signal of a probe learned as a central control probe without priority, the switching position Up or Down is activated in a targeted manner. Without priority because this function of other tax
€71.69
Eltako FSR14-4x RS485-Bus actuator 4-channel
Eltako FSR14-4x RS485-Bus actuator 4-channel
3-10 days
Current surge relays for mounting on support rail DIN-EN 60715 TH35, 16 A/250 V AC, potential-separated from supply voltage, with DX technology, bidirectional, stand-by-loss only 0.1 Watt current surge relays with 4 channels, each 1 closer 4A/250V AC, -Glüh lamps 1000W, potential-separated from supply voltage, with DX. Bidirectional. Stand-by loss only 0.1 Watt. Connection to Eltako-RS485-Bus. Cross-wiring bus and power supply with plug-in bridge. To this end, simply connect the N conductor to the terminal (N) and L to K(L). This results in an additional stand-by loss of only 0.1 Watt. If all 4 relays of the FSR14-4x are switched on, 0.7 watts are required. If the supply voltage fails, it is switched off in a defined manner. The channels can be taught independently as ES and/or ER channels. Scene control: A plurality of channels of one or more FSR14-4x can be switched on or off to one scene with one of the four control signals of a pushbutton learned as a scene scanner. Central commands on the PC are sent with the building radio visualization and control software GFVS. Learn one or more FSR14-4x on PC. With the rotary switches, the probes are learned and the 4 channels are tested if necessary. The LED under the upper rotary switch accompanies the learning process according to the user manual and displays control commands during operation by short flashing. Width in division units: 1 Max. Switching current: 4 A Max. Switching power: 1000 W Max. Number of switching outputs: 4 Bus system EIB/KNX: No Bus system Funkbus: Yes Bus system Powernet: No Bus connection included: Yes Bus system LON: No On site/hand operation: Yes With LED indicator: No Different phases connectable: No Modular expansion option: No
€70.05