PROTEC.class PSI NH 3 TR 630 A SECURITY
PROTEC.class PSI NH 3 TR 630 A SECURITY
2-7 days
In accordance with DIN WDE 0636 Part 2, DIN 43620 and DIN EN/IEC 60269-1 and DIN EN/IEC 60269-2, operating class (gL)-gG full-range safety inserts (for cable and cable protection) for general applications Rated current: 630 A Size: NH3 Power: 43 W
€34.52
PROTEC.class PSI NH 3 TR 500 A SECURITY
PROTEC.class PSI NH 3 TR 500 A SECURITY
2-7 days
In accordance with DIN WDE 0636 Part 2, DIN 43620 and DIN EN/IEC 60269-1 and DIN EN/IEC 60269-2, operating class (gL)-gG full-range safety inserts (for cable and cable protection) for general applications Rated current: 500 A Size: NH3 Power: 38 W
€34.52
PROTEC.class PSI NH 3 TR 425 A SECURITY
PROTEC.class PSI NH 3 TR 425 A SECURITY
2-7 days
In accordance with DIN WDE 0636 Part 2, DIN 43620 and DIN EN/IEC 60269-1 and DIN EN/IEC 60269-2, operating class (gL)-gG full-range safety inserts (for cable and cable protection) for general applications Rated current: 425 A Size: NH3 Power: 34 W
€30.70
PROTEC.class PSI NH 3 TR 400 A SECURITY
PROTEC.class PSI NH 3 TR 400 A SECURITY
2-7 days
In accordance with DIN WDE 0636 Part 2, DIN 43620 and DIN EN/IEC 60269-1 and DIN EN/IEC 60269-2, operating class (gL)-gG full-range safety inserts (for cable and cable protection) for general applications Rated current: 400 A Size: NH3 Power: 32 W
€30.70
PROTEC.class PSI NH 3 TR 315 A SECURITY
PROTEC.class PSI NH 3 TR 315 A SECURITY
2-7 days
In accordance with DIN WDE 0636 Part 2, DIN 43620 and DIN EN/IEC 60269-1 and DIN EN/IEC 60269-2, operating class (gL)-gG full-range safety inserts (for cable and cable protection) for general applications Rated current: 315 A Size: NH3 Power: 25 W
€22.51
PROTEC.class PSI NH 2 TR 80 A SECURITY
PROTEC.class PSI NH 2 TR 80 A SECURITY
2-7 days
In accordance with DIN WDE 0636 Part 201, DIN 43620 as well as DIN EN/IEC 60269-1 and DIN EN/IEC 60269-2 Nominal voltage: AC 500 W Portable handle tabs made of metal with hinge detectors. Selectivity factor: 1.6. Operating class (gL)-gG: Full range safety inserts (for cable and cable protection) for general applications. Measurement voltage: 500 W. Measurement switch-off capacity: 120 ka. Measurement frequency: 45 Ö62 Hz. Steatit/Cordierite insulating body. Single-piece full contact knives with surface treatment. Anti-magnetic cover plate made of aluminum alloy. Copper melting ladder. Rated current: 80 A Size: NH2 Power: 8.3 W
€15.00
PROTEC.class PSI NH 2 TR 63 A SECURITY
PROTEC.class PSI NH 2 TR 63 A SECURITY
2-7 days
In accordance with DIN WDE 0636 Part 201, DIN 43620 as well as DIN EN/IEC 60269-1 and DIN EN/IEC 60269-2 Nominal voltage: AC 500 W Portable handle tabs made of metal with hinge detectors. Selectivity factor: 1.6. Operating class (gL)-gG: Full range safety inserts (for cable and cable protection) for general applications. Measurement voltage: 500 W. Measurement switch-off capacity: 120 ka. Measurement frequency: 45 Ö62 Hz. Steatit/Cordierite insulating body. Single-piece full contact knives with surface treatment. Anti-magnetic cover plate made of aluminum alloy. Copper melting ladder. Measurement current: 63 A Size: NH2 Power: 6.8 W
€15.00
PROTEC.class PSI NH 2 TR 50 A SECURITY
PROTEC.class PSI NH 2 TR 50 A SECURITY
2-7 days
In accordance with DIN WDE 0636 Part 201, DIN 43620 as well as DIN EN/IEC 60269-1 and DIN EN/IEC 60269-2 Nominal voltage: AC 500 W Portable handle tabs made of metal with hinge detectors. Selectivity factor: 1.6. Operating class (gL)-gG: Full range safety inserts (for cable and cable protection) for general applications. Measurement voltage: 500 W. Measurement switch-off capacity: 120 ka. Measurement frequency: 45 Ö62 Hz. Steatit/Cordierite insulating body. Single-piece full contact knives with surface treatment. Anti-magnetic cover plate made of aluminum alloy. Copper melting ladder. Rated current: 50 A Size: NH2 Power: 4.1 W
€15.00
PROTEC.class PSI NH 2 TR 400 A SECURITY
PROTEC.class PSI NH 2 TR 400 A SECURITY
2-7 days
In accordance with DIN WDE 0636 Part 201, DIN 43620 as well as DIN EN/IEC 60269-1 and DIN EN/IEC 60269-2 Nominal voltage: AC 500 W Portable handle tabs made of metal with hinge detectors. Selectivity factor: 1.6. Operating class (gL)-gG: Full range safety inserts (for cable and cable protection) for general applications. Measurement voltage: 500 W. Measurement switch-off capacity: 120 ka. Measurement frequency: 45 Ö62 Hz. Steatit/Cordierite insulating body. Single-piece full contact knives with surface treatment. Anti-magnetic cover plate made of aluminum alloy. Copper melting ladder. Rated current: 400 A Size: NH2 Power: 28.5 W
€17.60
PROTEC.class PSI NH 2 TR 40 A SECURITY
PROTEC.class PSI NH 2 TR 40 A SECURITY
2-7 days
In accordance with DIN WDE 0636 Part 201, DIN 43620 as well as DIN EN/IEC 60269-1 and DIN EN/IEC 60269-2 Nominal voltage: AC 500 W Portable handle tabs made of metal with hinge detectors. Selectivity factor: 1.6. Operating class (gL)-gG: Full range safety inserts (for cable and cable protection) for general applications. Measurement voltage: 500 W. Measurement switch-off capacity: 120 ka. Measurement frequency: 45 Ö62 Hz. Steatit/Cordierite insulating body. Single-piece full contact knives with surface treatment. Anti-magnetic cover plate made of aluminum alloy. Copper melting ladder. Rated current: 40 A Size: NH2
€15.00
PROTEC.class PSI NH 2 TR 355 A SECURITY
PROTEC.class PSI NH 2 TR 355 A SECURITY
2-7 days
In accordance with DIN WDE 0636 Part 201, DIN 43620 as well as DIN EN/IEC 60269-1 and DIN EN/IEC 60269-2 Nominal voltage: AC 500 W Portable handle tabs made of metal with hinge detectors. Selectivity factor: 1.6. Operating class (gL)-gG: Full range safety inserts (for cable and cable protection) for general applications. Measurement voltage: 500 W. Measurement switch-off capacity: 120 ka. Measurement frequency: 45 Ö62 Hz. Steatit/Cordierite insulating body. Single-piece full contact knives with surface treatment. Anti-magnetic cover plate made of aluminum alloy. Copper melting ladder. Rated current: 355 A Size: NH2 Power: 31.5 W
€17.60