Trigger characteristicCNumber of poles (total)1Number of secured poles1Rated currentA10Measurement voltageV230Measurement switching capacity Icn according to EN 60898 at 230 VKA10Measurement switching capacity Icn according to EN 60898 at 400 VKA10Measurement switching capacity Icu according to IEC 60947-2 at 230 VKA0Measurement switching capacity Icu according to IEC 60947-2 at 400 VKA0Type of voltageACEnergy limiting class3FrequencyHZ50 to 60Interconnecting neutral conductornoSuitable for underground installationnoOvervoltage category3Pollution2Width in division units1Installation depthmmANNEXAdditional equipment possibleyesType of protection (IP)IP20
Trigger characteristicCNumber of poles (total)1Number of secured poles1Rated currentA13Measurement voltageV230Measurement switching capacity Icn according to EN 60898 at 230 VKA10Measurement switching capacity Icn according to EN 60898 at 400 VKA10Measurement switching capacity Icu according to IEC 60947-2 at 230 VKA0Measurement switching capacity Icu according to IEC 60947-2 at 400 VKA0Type of voltageACEnergy limiting class3FrequencyHZ50 to 60Interconnecting neutral conductornoSuitable for underground installationnoOvervoltage category3Pollution2Width in division units1Installation depthmmANNEXAdditional equipment possibleyesType of protection (IP)IP20
Trigger characteristicCNumber of poles (total)3Number of secured poles3Rated currentA13Measurement voltageV400Measurement switching capacity Icn according to EN 60898 at 230 VKA10Measurement switching capacity Icn according to EN 60898 at 400 VKA10Measurement switching capacity Icu according to IEC 60947-2 at 230 VKA0Measurement switching capacity Icu according to IEC 60947-2 at 400 VKA0Type of voltageACEnergy limiting class3FrequencyHZ50 to 60Interconnecting neutral conductornoSuitable for underground installationnoOvervoltage category3Pollution2Width in division units3Installation depthmmANNEXAdditional equipment possibleyesType of protection (IP)IP20
LS switch 16A/1pol/C 242206Measurement switching capacity according to EN 60898:10kAProtection type (IP):IP20Quantity:Trigger characteristic:CMeasurement current:16AFrequency:50Hz
Eaton Circuit breaker LS switch 16A/3pol/C Trigger characteristic: CNumber of poles (total): 3Number of secured poles: 3Rated current A: 16Measurement voltage V: 400Measurement switching capacity Icn according to EN 60898 at 230 Vk A: 10Measurement switching capacity Icn according to EN 60898 at 400 V kA: 10Measurement switching capacity Icu according to IEC 60947-2 at 230 V kA: 0Measurement switching capacity Icu according to IEC 60947-2 at 400 V kA: 0Type of voltage: ACEnergy limiting class: 3Frequency Hz: 50 - 60Interactive neutral conductor: noSuitable for underground installation: noOvervoltage category: 3Level of pollution: 2Width in division units: 3Installation depth mm: 70.5Additional equipment possible: yesProtection type (IP): IP20
LS switch 16A/3pol+N/CMeasurement switching capacity according to EN 60898:10kAInteractive neutral conductor: yesProtection type (IP):IP20Construction width:70mmSize (according to DIN 43880):4Number of poles:3+NTrigger characteristic:CMeasurement voltage:230/400AC48DCV, Rated current:16AInstallation depth:60mmType of voltage:AC/DCFrequency:50/60Hz