Eaton LS

Eaton PLSM-B10/3N-MW LS-Schalter 10A/3-pol+N/B 10kA 242513
Eaton PLSM-B10/3N-MW LS switch 10A/3-pol+N/B 10kA 242513
2-10 days
Basic functionCable switchPole3-pole+NTrigger characteristicBApplicationSwitching devices for housing and purpose constructionRated currentInA10Measurement switching capacity according to IEC/EN 60898-1KA10Product rangePLSM
€123.42
Eaton PLHT-C50-V LS-Schalter 50A/1pol/C 25KA, V-Sondertyp 248106
Eaton PLHT-C50-V LS switch 50A/1pol/C 25KA, V-special type 248106
2-7 Tage
Circuit breaker, 1-pole, rated current 50A, tripping characteristic C, rated operating voltage 230/400V, rated switching capacity according to IEC/EN 60947-2: 25kA, cap mounting dimension 45mm, installation width 1.5TE (27mm), hat rail mounting, clamping cross section 2.5-50 sqm
€90.02
Eaton PLSM-C32/3N-MW LS-Schalter 32A/3pol+N/C 242546
Eaton PLSM-C32/3N-MW LS switch 32A/3pol+N/C 242546
2-5 days
Trigger characteristicCNumber of poles (total)4Number of secured poles4Rated currentA32Measurement voltageV400Measurement switching capacity Icn according to EN 60898 at 230 VKA10Measurement switching capacity Icn according to EN 60898 at 400 VKA10Measurement switching capacity Icu according to IEC 60947-2 at 230 VKA0Measurement switching capacity Icu according to IEC 60947-2 at 400 VKA0Type of voltageACEnergy limiting class3FrequencyHZ50 to 60Interconnecting neutral conductoryesSuitable for underground installationnoOvervoltage category3Pollution2Width in division units4Installation depthmmANNEXAdditional equipment possibleyesType of protection (IP)IP20
€75.24
Eaton 242379 PLSM-B16/2-MW LS-Schalter 16A/2pol/B
Eaton 242379 PLSM-B16/2-MW LS switch 16A/2pol/B
2-5 days




Trigger characteristic



B



Number of poles (total)



2



Number of secured poles



2



Rated current


A
16



Measurement voltage


V
400



Measurement switching capacity Icn according to EN 60898 at 230 V


KA
10



Measurement switching capacity Icn according to EN 60898 at 400 V


KA
10



Measurement switching capacity Icu according to IEC 60947-2 at 230 V


KA
0



Measurement switching capacity Icu according to IEC 60947-2 at 400 V


KA
0



Type of voltage



AC



Energy limiting class



3



Frequency


HZ
50 to 60



Interconnecting neutral conductor



no



Suitable for underground installation



no



Overvoltage category



3



Pollution



2



Width in division units



2



Installation depth


mm
ANNEX



Additional equipment possible



yes



Type of protection (IP)



IP20


€72.00
Eaton PLSM-B25/3N-MW LS-Schalter 25A/3pol+N/B 242519
Eaton PLSM-B25/3N-MW LS switch 25A/3pol+N/B 242519
2-5 days




Trigger characteristic



B



Number of poles (total)



4



Number of secured poles



4



Rated current


A
25



Measurement voltage


V
400



Measurement switching capacity Icn according to EN 60898 at 230 V


KA
10



Measurement switching capacity Icn according to EN 60898 at 400 V


KA
10



Measurement switching capacity Icu according to IEC 60947-2 at 230 V


KA
0



Measurement switching capacity Icu according to IEC 60947-2 at 400 V


KA
0



Type of voltage



AC



Energy limiting class



3



Frequency


HZ
50 to 60



Interconnecting neutral conductor



yes



Suitable for underground installation



no



Overvoltage category



3



Pollution



2



Width in division units



4



Installation depth


mm
ANNEX



Additional equipment possible



yes



Type of protection (IP)



IP20


€69.70
Eaton PLHT-C40-V LS-Schalter 40A/1pol/C 25KA, V-Sondertyp 248105
Eaton PLHT-C40-V LS switch 40A/1pol/C 25KA, V-special type 248105
2-7 days
Circuit breaker, 1-pole, rated current 40A, tripping characteristic C, rated operating voltage 230/400V, rated switching capacity according to IEC/EN 60947-2: 25kA, cap mounting dimension 45mm, installation width 1.5TE (27mm), DIN rail mounting, clamping cross-section 2.5-50 sqm
€63.49
Eaton PLSM-B20/3N-MW LS-Schalter 20A/3pol+N/B 242518
Eaton PLSM-B20/3N-MW LS switch 20A/3pol+N/B 242518
2-5 days




Trigger characteristic



B



Number of poles (total)



4



Number of secured poles



4



Rated current


A
20



Measurement voltage


V
400



Measurement switching capacity Icn according to EN 60898 at 230 V


KA
10



Measurement switching capacity Icn according to EN 60898 at 400 V


KA
10



Measurement switching capacity Icu according to IEC 60947-2 at 230 V


KA
0



Measurement switching capacity Icu according to IEC 60947-2 at 400 V


KA
0



Type of voltage



AC



Energy limiting class



3



Frequency


HZ
50 to 60



Interconnecting neutral conductor



yes



Suitable for underground installation



no



Overvoltage category



3



Pollution



2



Width in division units



4



Installation depth


mm
ANNEX



Additional equipment possible



yes



Type of protection (IP)



IP20


€60.44
Eaton PLSM-C25/3N-MW LS-Schalter 25A/3pol+N/C 242545
Eaton PLSM-C25/3N-MW LS switch 25A/3pol+N/C 242545
2-5 days




Trigger characteristic



C



Number of poles (total)



4



Number of secured poles



4



Rated current


A
25



Measurement voltage


V
400



Measurement switching capacity Icn according to EN 60898 at 230 V


KA
10



Measurement switching capacity Icn according to EN 60898 at 400 V


KA
10



Measurement switching capacity Icu according to IEC 60947-2 at 230 V


KA
0



Measurement switching capacity Icu according to IEC 60947-2 at 400 V


KA
0



Type of voltage



AC



Energy limiting class



3



Frequency


HZ
50 to 60



Interconnecting neutral conductor



yes



Suitable for underground installation



no



Overvoltage category



3



Pollution



2



Width in division units



4



Installation depth


mm
ANNEX



Additional equipment possible



yes



Type of protection (IP)



IP20


€58.80
Eaton PLSM-C32/3-MW LS switch 32A/3pol/C 242477
Eaton PLSM-C32/3-MW LS switch 32A/3pol/C 242477
2-5 days




Auslösecharakteristik



C



Polzahl (gesamt)



3



Anzahl der abgesicherten Pole



3



Bemessungsstrom


A
32



Bemessungsspannung


V
400



Bemessungsschaltvermögen Icn nach EN 60898 bei 230 V


kA
10



Bemessungsschaltvermögen Icn nach EN 60898 bei 400 V


kA
10



Bemessungsschaltvermögen Icu nach IEC 60947-2 bei 230 V


kA
0



Bemessungsschaltvermögen Icu nach IEC 60947-2 bei 400 V


kA
0



Spannungsart



AC



Energiebegrenzungsklasse



3



Frequenz


Hz
50 - 60



Mitschaltender Neutralleiter



nein



Geeignet für Unterputz-Installation



nein



Überspannungskategorie



3



Verschmutzungsgrad



2



Breite in Teilungseinheiten



3



Einbautiefe


mm
70.5



Zusatzeinrichtungen möglich



ja



Schutzart (IP)



IP20


€52.27