List of products by brand ABB

ABB 2CDG110074R0011 UD/S2.300.2 Universal Dymator, 2x, 300 VA, REG
ABB 2CDG110074R0011 UD/S2.300.2 Universal Dymator, 2x, 300 VA, REG
2-7 days
For switching and dimming light bulbs, 230V halogen lamps or low-voltage halogen lamps on wound or electronic transformers (automatic load detection). Output power 2x300 VA to 45 °C ambient temperature, as well as max. 500 VA if only one output is operated. Both outputs are independent of one another and can be fed from different phases. Extensive application program with scene and time functions.
€437.18
ABB 2CTB815710R1800 OVR T1-T2 3L 12.5-275s P QS Combi Recipient T1-T2 12.5kA/Pol, TNC
ABB 2CTB815710R1800 OVR T1-T2 3L 12.5-275s P QS Combi Recipient T1-T2 12.5kA/Pol, TNC
2-7 days
Combined lightning and overvoltage protection device SPD type 1+2 for protection of low-voltage consumer systems against flash currents and overvoltages. Tested SPD type 1 and type 2 according to DIN EN 61643-11. The devices can be used for use as an overvoltage protection device according to WDE 0100 part 443 and part 534, as well as within the framework of the lightning protection zone concept. The devices are compatible with the System per M compact series. Optionally, the SPD is equipped with a floating contact. The variants with evacuation varistor – (s) offer an additional protection of the system in that at the end of the service life, the surge arrester is not completely separated from the network, but a basic protection is still guaranteed by an additional smaller varistor and the system is thus still protected until the surge arrester is replaced.
€453.08
ABB 2CDG110092R0011 BE/S8.20.2.1 binary input, 8x, contact query, REG
ABB 2CDG110092R0011 BE/S8.20.2.1 binary input, 8x, contact query, REG
2-7 days
The device queries 8 potential-free contacts with internally generated interrogation voltage. The input state is displayed over 8 yellow LED’s. The binary inputs allow the detection of 8 independent input signals. Each channel has a button for manual operation. The devices are used by ABB i-bus® supplies and does not require additional power supply.
€476.93
ABB 2CDG110146R0011 SV/S30.640.5.1 Power supply with diagnostic function, 640 mA, REG
ABB 2CDG110146R0011 SV/S30.640.5.1 Power supply with diagnostic function, 640 mA, REG
2-7 days
The KNX voltage supply 640 ma with diagnostic function and extended LED display generates and monitors the KNX system voltage (SELV). With the integrated throttle, the bus line is decoupled from the voltage supply. The voltage output is short-circuit-proof and overload-proof. The two-color LED indicates the status of the device. The device has an additional short-circuit-proof and overload-proof 30 W DC voltage output. This can be used for feeding a further bus line (in conjunction with a separate throttle). The voltage supply has a wide-range input for the supply voltage in the range 85Å265 W AC,50/60 Hz.
€486.86
ABB 2CDG110161R0011 SA/S8.16.2.1 Switch actuator, 8 times, 16 A, REG
ABB 2CDG110161R0011 SA/S8.16.2.1 Switch actuator, 8 times, 16 A, REG
2-7 days
Switches independent electrical consumers via potential-free contacts 8 ABB i-bus®. The manual operation of the contact is possible for each output. The switching state of the contact is displayed. The 16A-AC1 series is suitable for switching ohmic, inductive and capacitive loads.
€496.80
ABB 2CDG110171R0011 LK/S4.2 Line Coupler, REG
ABB 2CDG110171R0011 LK/S4.2 Line Coupler, REG
2-7 days
The ABB i-bus® KNX Line Coupler LK/S 4.2 is a series installation device with 2 TE module width. It is used as a line/range coupler or line amplifier. As a line coupler, the LK/S connects a line with a main line, as a region coupler a main line with a region line. It provides a galvanic separation. The group addresses of the main groups 14 . . . 31 can be filtered in conjunction with the ETS 4 .
€496.80
ABB 2CSF204592R1400 F204B-40/0,03 FI circuit breaker type B 4P,40A,30mA,short timeverz.,3kA,4TE
ABB 2CSF204592R1400 F204B-40/0,03 FI circuit breaker type B 4P,40A,30mA,short timeverz.,3kA,4TE
2-7 days
Fault current protection devices (Rccbs) offer personal and property protection as well as protection against electrically ignited fires according to DIN WDE 0100-410 and DIN WDE 0100-530. The F200 series fault current protection switches ensure protection against sinusoidal alternating currents, pulsating currents and smooth direct fault currents. As well as fault protection (protection in indirect contact), additional protection (with I?n = 30 ma) and fire protection (with I?n = 300 ma). They meet product standards for type A IEC/EN 61008-1, 61008-2-1, 61543 (WDE 0664 10, 11, 30) and type B DIN EN 62423 (WDE 0664-40). Areas of application are predominantly in industrial and commercial applications. The extensive range of accessories offers you everything you need for your installation tasks. The RCCB type B is suitable for non-linear circuits that can generate fault currents with smooth direct fault currents and with different (high/) frequencies. These components are located in electronic operating means such as frequency converters. The RCCB type B has a frequency range of 0...2 khz to detect the fault current and offer a high system availability.
€556.42
ABB 2CKA006220A0024 6251/8 Sens/switch 8/8-f, REG
ABB 2CKA006220A0024 6251/8 Sens/switch 8/8-f, REG
2-7 days
Combination device with 8 binary inputs and 8 switching actuators. Conventional probes or auxiliary contacts can be connected to 8 channels. The information of the contact query can be used for controlling Busch-free@home® actuators or for detecting status information. The contact interrogation voltage is provided by the device itself. Maximum cable length for cable cross section 1.5 mm2
€558.40
ABB 2CDG120039R0011 FW/S8.2.1 Radio clock, 8 channels, REG
ABB 2CDG120039R0011 FW/S8.2.1 Radio clock, 8 channels, REG
2-7 days
The radio clock sends the current time and date to the bus. The time can optionally be received by a DCF or GPS antenna. Furthermore, the radio control clock is used for simple setting of time programs.
€566.35
ABB 2CMA100179R1000 B24 113-100 transducer counter, M-bus “steel”, 3 phases, transducer connection 6A
ABB 2CMA100179R1000 B24 113-100 transducer counter, M-bus “steel”, 3 phases, transducer connection 6A
2-7 days
The following values are output via a seven-segment display with up to 7 digits: active energy (class 1), power, currents, voltages (L-L; L-N) and frequency both per phase and total. The communication can take place via the integrated interface M-Bus or via the infrared interface for connecting a KNX module. The energy meter has an output. This can optionally be used as a pulse output for outputting the active energy or as an alarm output. Up to 25 alarm values (swell values with time delay) can be set here. The counter is calibrated according to MID and approved according to IEC. The installation width is 4 DIN modules.
€570.57
ABB 2CDG110122R0011 JRA/S8.230.2.1 Blind / roller shutter actuator, 8x, 230 V AC, manual operation, REG
ABB 2CDG110122R0011 JRA/S8.230.2.1 Blind / roller shutter actuator, 8x, 230 V AC, manual operation, REG
2-7 days
For controlling a maximum of eight independent 230 W AC drives for positioning blinds, roller shutters, awnings and other hangings, as well as for controlling doors, windows and ventilation flaps. With manual operation directly on the device. No auxiliary voltage required. The outputs are interlocked electromechanically. Functions: On/off, lamella adjustment/stop, position and scene control, safety functions, sun protection and heating/cooling automatic, status messages.
€582.82
ABB 2CDG110162R0011 SA/S12.16.2.1 Switch actuator, 12 times, 16 A, REG
ABB 2CDG110162R0011 SA/S12.16.2.1 Switch actuator, 12 times, 16 A, REG
2-7 days
Switches independent electrical consumers via potential-free contacts 12 ABB i-bus®. The manual operation of the contact is possible for each output. The switching state of the contact is displayed. The 16A-AC1 series is suitable for switching ohmic, inductive and capacitive loads.
€586.22
ABB 2CSF204592R3400 F204B-40/0,3 FI circuit breaker type B 4P,40A,300mA,short timeverz.,3kA,4TE
ABB 2CSF204592R3400 F204B-40/0,3 FI circuit breaker type B 4P,40A,300mA,short timeverz.,3kA,4TE
2-7 days
Fault current protection devices (Rccbs) offer personal and property protection as well as protection against electrically ignited fires according to DIN WDE 0100-410 and DIN WDE 0100-530. The F200 series fault current protection switches ensure protection against sinusoidal alternating currents, pulsating currents and smooth direct fault currents. As well as fault protection (protection in indirect contact), additional protection (with I?n = 30 ma) and fire protection (with I?n = 300 ma). They meet product standards for type A IEC/EN 61008-1, 61008-2-1, 61543 (WDE 0664 10, 11, 30) and type B DIN EN 62423 (WDE 0664-40). Areas of application are predominantly in industrial and commercial applications. The extensive range of accessories offers you everything you need for your installation tasks. The RCCB type B is suitable for non-linear circuits that can generate fault currents with smooth direct fault currents and with different (high/) frequencies. These components are located in electronic operating means such as frequency converters. The RCCB type B has a frequency range of 0...2 khz to detect the fault current and offer a high system availability.
€596.16
ABB 2CDG110198R0011 DG/S1.64.1.1 DALI Gateway, Basic, 1x, REG
ABB 2CDG110198R0011 DG/S1.64.1.1 DALI Gateway, Basic, 1x, REG
2-7 days
To drive DALI participants via ABB i-bus®. A DALI output for max. 64 DALI participants. The DALI power supply is integrated. The activation can take place per DALI subscriber (64), via groups (16), together in the broadcast or via scenes (16). Extensive error and interference messages are available. DALI emergency light converter(64) according to EN 62386-202 are supported. The function test and continuous tests can be triggered via KNX via the emergency light converter and the result can be made available on the KNX. Slave, staircase light, locking and forced guidance function are integrated. The DALI telegram rate is variable. A separate diagnostic and commissioning tool is provided for individual re-addressing of the DALI participants or group assignment, ABB i-bus tool available.
€616.03
ABB 2CDG110175R0011 IPR/S3.1.1 IP router, REG
ABB 2CDG110175R0011 IPR/S3.1.1 IP router, REG
2-7 days
forms the interface between KNX installations and IP networks and works according to the KNXnet/IP specification (tunneling and routing). The IPR/S can be used as a fast line or range coupler (routing). The complete filter table for all main groups (0-31) can be loaded. With the ETS, KNX devices can be programmed via LAN. 5 tunneling servers are available for this and for other clients. The IP address of the IPR/S can be set or received by a DHCP server. The power supply is over 12..30 W DC or alternating via Power-over-Ethernet (Poe) to IEEE 802.3af Class 1. Alternatiw to KNX Standard Communication (Multicast) can communicate up to 10 IPR/S 3.1.1 via Unicast.
€616.03
close