List of products by brand Hager

Hager CJS440D FI-Schalter 4P 6kA 40A 30mA Typ G/A-VS
Hager CJS440D FI switch 4P 6kA 40A 30mA type G/A-VS
2-5 days
FI switch 4P 6kA 40A 30mA type G/A-VS. fault current protection switch (FI) according to EN 61008-1, EN 61008-2-1; VDE 0664 part 10 + 11, short-term delayed according to ÖVE E 8601, IP2x contact protection according to DIN VDE 0106 part 100. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, QuickBusbar according to EN 60898-1, external blue test button for semi-annual actuation and fault current tools. Easy removal from the phase rail composite. All products with ÖVE and VDE characters. Labeling option directly on the device. Preservation: 40A according to OVE E 8101: 2019 or. limiting the operating current through downstream fuses.
€91.82
Hager ADS963D FI/LS 1P+N 6kA C-Charakteristik 13A 30mA
Hager ADS963D FI/LS 1P+N 6kA C-Characteristic 13A 30mA
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 13 A Trigger characteristic: C Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V Rated current13 ATrigger characteristicCRated value6Type of differential protectionASensitivity30 mANumber2 PNumber of modules2Rated operating voltage Ue240 VInsulation voltage500 VImpact strength4,000 VFrequency50 HzTorque2.1NmTotal loss power at rated current3.8 WDevice life, electrical switching games2000Machine life mechanical switching games2000Connection cross section with flexible conductor1 - 16mm2Connection cross section for rigid conductor1 - 25mm2Operating temperature-25 to 40 °CStorage temperature-25 to 70 °CHeight installed product94 mmWide installed product35 mmDeep Installed Product68 mm
€89.96
Hager ADS966D FI/LS 1P+N 6kA C-Charakteristik 16A 30mA
Hager ADS966D FI/LS 1P+N 6kA C-Characteristic 16A 30mA
3-7 working days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: C Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 VRated current16 ATrigger characteristicCRated value6Type of differential protectionASensitivity30 mANumber2 PNumber of modules2Rated operating voltage Ue240 VInsulation voltage500 VImpact strength4,000 VFrequency50 HzTorque2.1NmTotal loss power at rated current5.2 WDevice life, electrical switching games2000Machine life mechanical switching games2000Connection cross section with flexible conductor1 - 16mm2Connection cross section for rigid conductor1 - 25mm2Operating temperature-25 to 40 °CStorage temperature-25 to 70 °CHeight installed product94 mmWide installed product35 mmDeep Installed Product68 mm
€89.92
Hager ACS916D FI/LS 1P+N 6kA B-Charakteristik 16A 10mA Typ A QC
Hager ACS916D FI/LS 1P+N 6kA B-Characteristic 16A 10mA Type A QC
2-5 days
1P+N 6kA B-Characteristic 16A 10mA type A QC fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 16 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 10 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 V Rated current16 ATrigger characteristicBRated value6Type of differential protectionASensitivity10 mANumber2 PNumber of modules2Rated operating voltage Ue240 VInsulation voltage500 VImpact strength4,000 VFrequency50 HzTorque2.1NmDevice life, electrical switching games2000Machine life mechanical switching games2000Connection cross section with flexible conductor1 - 16mm2Connection cross section for rigid conductor1 - 25mm2Operating temperature-25 to 40 °CStorage temperature-25 to 70 °CHeight installed product94 mmWide installed product35 mmDeep Installed Product68 mm
€89.88
Hager ADS913D FI/LS 1P+N 6kA B-Charakteristik 13A 30mA
Hager ADS913D FI/LS 1P+N 6kA B-Characteristic 13A 30mA
2-5 days
fault current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, at the output up to 20 A and at the access up to 63 A. Simple individual removal from the phase rail composite. With VDE characters. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Nominal current: 13 A Trigger characteristic: B Nominal shutdown capability: 6 kA Type of differential protection: A Sensitivity: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 240 VRated current13 ATrigger characteristicBRated value6Type of differential protectionASensitivity30 mANumber2 PNumber of modules2Rated operating voltage Ue240 VInsulation voltage500 VImpact strength4,000 VFrequency50 HzTorque2.1NmTotal loss power at rated current3.8 WDevice life, electrical switching games2000Machine life mechanical switching games2000Connection cross section with flexible conductor1 - 16mm2Connection cross section for rigid conductor1 - 25mm2Operating temperature-25 to 40 °CStorage temperature-25 to 70 °CHeight installed product94 mmWide installed product35 mmDeep Installed Product68 mm
€89.17
Hager VH36AT small distributor HW,Volta, 3x12(+2)TE, IP30, B314xH595xT87mm
Hager VH36AT small distributor HW,Volta, 3x12(+2)TE, IP30, B314xH595xT87mm
2-5 days
Mounting type: hollow wallMaterial of housing: plasticProtection type: IP30Protection class: Protection class IIGWT glow wire test: 850 °CNumber of distribution rows: 3Number of modules: 36Number of doors: 1Door closure type: snap closureRAL colour number: 9010Color: whiteHeight installed product: 630 mmWide installed product: 348 mmDeep installed product: 94,5 mm
€87.14
Hager MCS625 cable protection switch 3P+N 6kA C-25A Quick Connect 4M
Hager MCS625 cable protection switch 3P+N 6kA C-25A Quick Connect 4M
2-5 Tage
Rated current:25 ATrigger characteristic:CNominal deactivation capacity:6Number of poles:4 PNumber of modules:4AC voltage:OF 230/400 VInsulation voltage:500 VFrequency:50/60 HzConnection type:QuickConnectTorque:2.8 NmTotal power loss under rated current:10.1 WDevice life, electrical switching games:4000Machine life mechanical switching games:20000Operating temperature:-25 to 60 °CStorage temperature:-25 to 80 °CHeight installed product:83.4 mmWide installed product:70 mmDeep Installed Product:70 mm
€86.44
Hager HAC308 3pin 80A
Hager HAC308 3pin 80A
2-5 days
3pin 80A load disconnector for hat rail or mounting plate load disconnector for mounting on hat rail or mounting plate, rotary drive directly on the device in the OFF state can be locked with a padlock. Ensures switching on and off under load and a safety disconnect function in all low-voltage circuits. Rated current: 80 A Rated operating voltage Ue: 380/415 V Isolation voltage: 800 V Number of poles: 3 P Number of modules: 3 Operating temperature: -20 ... 70 °C Connection type: Screwing technology Connection cross-section with rigid conductor: 35mm2
€84.44
Hager ESC463 Insta Protector 4S 63A/230VAC Coil:230VAC
Hager ESC463 Insta Protector 4S 63A/230VAC Coil:230VAC
2-5 Tage
Installation protector 63A 4 Locker 230V Protector in compact design according to EN 61095 and DIN VDE 0637-3 as well as contact protection according to DIN VDE 0106 part 100. Contact position display by display window, integrated labeling field and suitable for subsequent installation of additional device. Notes: If several devices are installed directly, a spacer (1/2 PLE) must be installed next to each second device. Rated current: 63 A control voltage AC current: 230 V Number of modules: 3 Rated operating voltage Ue: 400 V Frequency: 50 Hz Connection type: Screwing technology
€83.16
Hager VU36NWB Media distributor UP Underput 3-row, 1x hat rail, 2x mounting plate
Hager VU36NWB Media distributor UP Underput 3-row, 1x hat rail, 2x mounting plate
2-5 days
Multimedia base, volta, UPV, 3-row, 1x hat rail, 2x mounting plate installation small distributor base made of plastic, according to OVE EN 61439-1/-3, OVE EN 60670-24 and DIN 43871, suitable for use in residential buildings according to OVE E 8015 and for installation of protective insulation VDI components. Protection class IP30, protection class II insulated. Consisting of: plastic mooring box with standard line collection and cut-out line entry slider with snap fastening, integrated water balance. Hollow wall fastening with quick fixation lever, can be mounted laterally or at the top/bottom. Rotatable frame with ventilation door made of steel sheet with ventilation slits, powder-coated and baked, with 15 mm cleaning. Ventilation door, flush with inside hand-operable hinges. Door closure with front-butting handle depression and automatically fold back handle. Door stop right or left without frame removal. Preassembled perforated mounting plates made of galvanized steel sheet with 3.2 mm hole are installed. Mounted a cover rail for direct fastening of patch panels. As an accessory, a universal retaining bracket for the screwless fastening of VDI components can be ordered and installed directly on the perforated plate, a 3-fold protective contact socket (90° rotatable). Mounting Type: Unterputz RAL Color Number: 9010 Protection Type: IP30 Height Installed Product: 630.5 mm Width Installed Product: 348 mm Depth Installed Product: 94.5 mm
€83.10
Hager VU48AT Kleinverteiler UP,Volta,4x12(+2)TE,IP30,B335xH740xT90mm
On sale!
Hager VU48AT Kleinverteiler UP,Volta,4x12(+2)TE,IP30,B335xH740xT90mm
2-5 days



Number of rows:
4


Width in division units:
12


Material of housing:
Plastic


Protection type (IP):
IP30


Height:
755 mm


Width:
348 mm


Depth:
94.5 mm


Installation depth:
94.5 mm


With transparent lid:
No


Access:
Yes


EMC version:
No


Color:
white


RAL number:
9010


€82.20
Hager MCN632 LS switch 32A/3pol+N/C 6kA
Hager MCN632 LS switch 32A/3pol+N/C 6kA
2-5 days
Circuit breaker 3polig+N 6kA C-Characteristic 32A 4 modules circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails.Rated current: 32 ATrigger characteristic: CNominal shutdown capacity: 6 kANumber of poles: 4 PNumber of modules: 4AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power under rated current: 13 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 70 mmDeep installed product: 70 mm
€82.05