Windproof design with sealing membranes, milling hole Ø 68 mm, for plate thicknesses from 7 to max. 35 mm, flame resistance 850° C according to WDE 0606, integrated strain relief according to DIN WDE 0606 / DIN 49073, self-locking of the pipes, with connecting pieces, each 2 line introductions 3×1.5 mm2 and 3×2.5 mm2 or. 5 x 1.5 mm2 Diameter: 68 mm Depth: 61 mm With screws: Yes
Flat 4 screw domes for convenient mounting of all built-in devices. Flame resistance 650° C. according to WDE 0606 part 1 / DIN IEC 695 part 2-1. Standard distance of the screw domes 60 mm. Standard distance combination 71 mm. Full-insulated spacer, non-rotational. Introduction for IEC tube up to max. M 25. The pipe automatically engages the inner edge of the tunnel neck and does not project into the interior of the can. Application: Underput. Halogen-free. Ø: 60 mm. Depth: 41 mm, flat. Protection class: IP2X. Number of possible introductions: 6. Measurement voltage: 400W. Material: Polystryrol (PS) Version: without screws
Flat 4 screw domes for convenient mounting of all built-in devices. Flame resistance 650° C. according to WDE 0606 part 1 / DIN IEC 695 part 2-1. Standard distance of the screw domes 60 mm. Standard distance combination 71 mm. Full-insulated spacer, non-rotational. Introduction for IEC tube up to max. M 25. The pipe automatically engages the inner edge of the tunnel neck and does not project into the interior of the can. Application: Underput. Halogen-free. Ø: 60 mm. Depth: 41 mm, flat. Protection class: IP2X. Number of possible introductions: 6. Measurement voltage: 400W. Material: Polystryrol (PS) Version: with 2 device screws
Lower-put device blinds, deep 4 screw domes for convenient mounting of all built-in devices. Flame resistance 650° C. according to WDE 0606 part 1 / DIN IEC 695 part 2-1. Standard distance of the screw domes 60 mm. Standard distance combination 71 mm. Full-insulated spacer, non-rotational. Introduction for IEC tube up to max. M 25. The pipe automatically engages the inner edge of the tunnel neck and does not project into the interior of the can. Application: Underput. Halogen-free. Ø: 60 mm. Depth: 62 mm, deep. Protection class: IP2X. Number of possible introductions: 12. Rated voltage: 400W. Material: Polystryrol (PS) Version: with 2 device screws
Diameter 3.2 mm, Self-tapping thread, Corrision resistant, Version: Cross and slot available, Bit size Slot design: Slot depth: 0.8 mm + Tolerance range: 0.2 mm, Slot width: 0.8 mm + Tolerance range: 0.2 mm, Bit size: 1x50 mm or as smallest size 0,6x45 mm, bit size cross design: Philips Size 1 Length: 25 mm
With nail strap for UP mounting, flame resistance 650°C according to WDE 0606 Part 1 / DIN IEC 695 Part 2-1, standard distance of screw domes 60 mm, standard distance combination 71 mm, fully insulated spacer, non-rotational, introduction for IEC pipe up to max. M20, Halogen-free version: without screws Diameter: 60 mm Depth: 42 mm Colour: black With nail straps: Yes
With nail strap for UP mounting, flame resistance 650°C according to WDE 0606 Part 1 / DIN IEC 695 Part 2-1, standard distance of screw domes 60 mm, standard distance combination 71 mm, fully insulated spacer, non-rotational, introduction for IEC pipe up to max. M20, Halogen-free version: without screws Diameter: 60 mm Depth: 42 mm Colour: black With nail straps: Yes
Diameter 3.2 mm, Self-tapping thread, Corrision resistant, Version: Cross and slot available, Bit size Slot design: Slot depth: 0.8 mm + Tolerance range: 0.2 mm, Slot width: 0.8 mm + Tolerance range: 0.2 mm, Bit size: 1x50 mm or as smallest size 0,6x45 mm, bit size cross design: Philips Size 1 Length: 15 mm Version: slot
Diameter 3.2 mm, Self-tapping thread, Corrision resistant, Version: Cross and slot available, Bit size Slot design: Slot depth: 0.8 mm + Tolerance range: 0.2 mm, Slot width: 0.8 mm + Tolerance range: 0.2 mm, Bit size: 1x50 mm or as smallest size 0,6x45 mm, bit size cross design: Philips Size 1 Length: 40 mm
Lower-put device blinds, deep 4 screw domes for convenient mounting of all built-in devices. Flame resistance 650° C. according to WDE 0606 part 1 / DIN IEC 695 part 2-1. Standard distance of the screw domes 60 mm. Standard distance combination 71 mm. Full-insulated spacer, non-rotational. Introduction for IEC tube up to max. M 25. The pipe automatically engages the inner edge of the tunnel neck and does not project into the interior of the can. Application: Underput. Halogen-free. Ø: 60 mm. Depth: 62 mm, deep. Protection class: IP2X. Number of possible introductions: 12. Rated voltage: 400W. Material: Polystryrol (PS) Version: without screws
Flat 4 screw domes for convenient mounting of all built-in devices. Flame resistance 650° C. according to WDE 0606 part 1 / DIN IEC 695 part 2-1. Standard distance of the screw domes 60 mm. Standard distance combination 71 mm. Full-insulated spacer, non-rotational. Introduction for IEC tube up to max. M 25. The pipe automatically engages the inner edge of the tunnel neck and does not project into the interior of the can. Application: Underput. Halogen-free. Ø: 60 mm. Depth: 41 mm, flat. Protection class: IP2X. Number of possible introductions: 6. Measurement voltage: 400W. Material: Polystryrol (PS) Version: without screws
€48.67
This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Find out more here.