Switch/A or cans

PROTEC.class PASD425 branch switch 62mm 4hole M25 25 pieces
PROTEC.class PASD425 branch switch 62mm 4hole M25 25 pieces
2-7 days
Lower-put device blinds, deep 4 screw domes for convenient mounting of all built-in devices. Flame resistance 650° C. according to WDE 0606 part 1 / DIN IEC 695 part 2-1. Standard distance of the screw domes 60 mm. Standard distance combination 71 mm. Full-insulated spacer, non-rotational. Introduction for IEC tube up to max. M 25. The pipe automatically engages the inner edge of the tunnel neck and does not project into the interior of the can. Application: Underput. Halogen-free. Ø: 60 mm. Depth: 62 mm, deep. Protection class: IP2X. Number of possible introductions: 12. Rated voltage: 400W. Material: Polystryrol (PS) Version: without screws
€8.87
PROTEC.class PASD4G25 branch switch 62mm 4loch M25 25 pieces
PROTEC.class PASD4G25 branch switch 62mm 4loch M25 25 pieces
2-7 days
Lower-put device blinds, deep 4 screw domes for convenient mounting of all built-in devices. Flame resistance 650° C. according to WDE 0606 part 1 / DIN IEC 695 part 2-1. Standard distance of the screw domes 60 mm. Standard distance combination 71 mm. Full-insulated spacer, non-rotational. Introduction for IEC tube up to max. M 25. The pipe automatically engages the inner edge of the tunnel neck and does not project into the interior of the can. Application: Underput. Halogen-free. Ø: 60 mm. Depth: 62 mm, deep. Protection class: IP2X. Number of possible introductions: 12. Rated voltage: 400W. Material: Polystryrol (PS) Version: with 2 device screws
€14.43
PROTEC.class PASD4LG25 branch switch 62mm 4loch M25 150 pieces
PROTEC.class PASD4LG25 branch switch 62mm 4loch M25 150 pieces
2-7 days
Lower-put device blinds, deep 4 screw domes for convenient mounting of all built-in devices. Flame resistance 650° C. according to WDE 0606 part 1 / DIN IEC 695 part 2-1. Standard distance of the screw domes 60 mm. Standard distance combination 71 mm. Full-insulated spacer, non-rotational. Introduction for IEC tube up to max. M 25. The pipe automatically engages the inner edge of the tunnel neck and does not project into the interior of the can. Application: Underput. Halogen-free. Ø: 60 mm. Depth: 62 mm, deep. Protection class: IP2X. Number of possible introductions: 12. Rated voltage: 400W. Material: Polystryrol (PS) Version: without screws
€51.51
PROTEC.class PAZK 100100 UP branch box with lid
PROTEC.class PAZK 100100 UP branch box with lid
2-7 days
With lid, for clamps up to 4 mm2, material thermoplastic, protection: IP20, flame resistance box 650°C according to WDE 0606 Part 1 / DIN IEC 695 Part 2-1 Length: 100 mm Width: 100 mm Depth: 48 mm Halogen-free: Yes
€3.51
PROTEC.class PAZK 150150 UP branch box 150x150x62
PROTEC.class PAZK 150150 UP branch box 150x150x62
2-7 days
With lid, for clamps up to 4 mm2, material thermoplastic, protection: IP20, flame resistance box 650°C according to WDE 0606 Part 1 / DIN IEC 695 Part 2-1 Length: 150 mm Width: 150 mm Depth: 62 mm Halogen-free: Yes
€9.42
PROTEC.class PAZK 8080 UP branch box with lid
PROTEC.class PAZK 8080 UP branch box with lid
2-7 days
With lid, for clamps up to 4 mm2, material thermoplastic, protection: IP20, flame resistance box 650°C according to WDE 0606 Part 1 / DIN IEC 695 Part 2-1 Length: 80 mm Width: 80 mm Depth: 48 mm Halogen-free: Yes
€3.41
PROTEC.class PDD8100 UP double box 100 mm 8 hole
PROTEC.class PDD8100 UP double box 100 mm 8 hole
2-7 days
UPC double-walled box 8 hole without screw, bottom-walled box, UP-Dose DUPLEX is suitable for the opposite installation of UP cans in walls from 100 mm, usable can depth is 49 mm, continuous installation in one working step, without complicated installation of two sides, saving time and creating more wiring space, depth: 100 mm, material: PSHI. (24 hours): 35°C, Max. rel. Humidity at 25°C (short term): 90.% Max. relative humidity at 40°C: 50%
€1.93
PROTEC.class PED25 Electronic Dose Ø60mm 149x67mm M25
PROTEC.class PED25 Electronic Dose Ø60mm 149x67mm M25
2-7 days
Electronic-Dose Electronic-Dose with 4 screw domes. Material: PS, flame resistance 650°C. According to WDE 0606 part 1 / DIN IEC 695 part 2-1. Introduction: 11 x M20, 6 x M25. The pipe automatically engages the inner edge of the tunnel neck and does not project into the interior of the can. Measurement voltage: 400 W. Halogen-free. Protection class: IP2X. Application: Underput Design: with 2 screws
€7.85