Additional device for door/video intercom

Gira 127800 data closing element Doorko
Gira 127800 data closing element Doorko
Door communication system (output) The interference filter is used when three or more video distributors are used in succession in a topology. The interference filter is connected to the BUS terminals of the bus coupler of the most remote housing station.
Gira 121100 Switchgear UP Door Co
Gira 121100 Switchgear UP Door Co
Door Communications Underput Switch Features: - Underput Switch for controlling an external gong or other consumer via the Gira Door communication bus. - Control of a potential-free switching contact (24 V SELV 50 A to 1.6 A AC DC) via the 2-wire bus. - The underput switch is controllable via: the keys door and light at the apartment station, the floor call button at the apartment station, the call button at the door station, the call button at the apartment station, the keys of a telephone (in conjunction with the TKS-TK gateway), a potential-free button (in connection with the door communication button interface 2x). - The sub-put switch can be operated in four different operating modes: switching, timer s, timer min and pulse. - impulse function for controlling existing stairway machines. - switching time, depending on the set function, adjustable from 1 to 10 s or. 1 to 10 min. - LED display for programming, function selection and time setting. Notes : - The underput switch is provided for installation in a deep device box (60 mm deep) behind a door communication bus coupler.
Gira 128900 Switch actuator REG Türko
Gira 128900 Switch actuator REG Türko
Door communication switch REG Features: - Switch actuator for switching light, driving a door opener on side doors or other functions via the Gira Door communication bus. - Control of a potential-free switching contact 230 V 10 A via the 2-wire bus. - The switch actuator is controllable via: the keys door and light at the apartment station, the call button at the door station, the call button at the apartment station, the keys of a telephone (in conjunction with TKS-TK-Gateway). - The switch actuator can be operated in five different operating modes: switching, timer s, timer min, pulse and door opener. - impulse function for controlling existing stairway machines. - Binary input for switching functions via a connected mechanical probe. - switching time, depending on the set function, continuously adjustable from 1 to 10 s or. 1 to 10 min. Notes : - The switch actuator is provided for installation in the subdistribution. If this is not possible, use commercially available plaster distributors. - With this component, the construction of door communication systems with more than 30 subscribers is possible.