List of products by brand ABB

ABB 2CDG110091R0011 BE/S4.230.2.1 binary input, 4 times, 10-230 V, REG
ABB 2CDG110091R0011 BE/S4.230.2.1 binary input, 4 times, 10-230 V, REG
2-7 days
The device records four AC/DC signals in the voltage range of 10...230 V. The input state is displayed via 4 yellow LED’s. Binary inputs enable a total of 4 input signals (in 2 groups). Each channel has a button for manual operation. The devices are used by ABB i-bus® supplies and does not require additional power supply.
€288.14
ABB 2CDG120004R0011 ST/K1.1 Electric actuator AP
ABB 2CDG120004R0011 ST/K1.1 Electric actuator AP
2-7 days
The electromotive actuator ST/K 1.1 is a proportional actuator for controlling radiator valves via ABB i-bus®. The actuator is mounted on thermostat valve bottom parts (accessible valve adapter VA10, VA78 included). The control takes place via a steady EIB / KNX room temperature controller. The actual valve position is indicated by 5 LEDs. Furthermore, the electromotive actuator ST/K 1.1 has two binary inputs which can be used, for example, for connecting a presence contact and/or window contact. The status of these inputs can be sent to the EIB / KNX.
€288.14
ABB 2CKA006220A0025 6254/0.6 Heating actuator 6-fold, REG
ABB 2CKA006220A0025 6254/0.6 Heating actuator 6-fold, REG
2-7 days
For controlling thermoelectric actuators in heating/cooling systems. Up to 3 actuators 6164/10-102 or 1 actuator 6164/11-102 can be connected per output. The outputs are short-circuit and overload safe. The bus connection takes place via the enclosed bus terminal.
€283.08
ABB 2CPX031388R9999 UK648MW Media Distributor, Underput 4-row, Wifi Door
ABB 2CPX031388R9999 UK648MW Media Distributor, Underput 4-row, Wifi Door
2-7 days
The media distributors of the UK600 series are designed for under-put assembly. They convince with many new and unique technical features. Thus, an up to 200 % larger connection space allows easy and efficient installation of the devices. Through the generous space, all conceivable devices such as routers or other media modules find their safe place. Modular perforated plate mounting plates allow easy installation of the devices and an integrated rotatable 3-way socket ensures the power supply. With an optional removable frame, the UK600 is turned to eye-catching and integrated into any environment. The distributions can be used in undercut and hollow wall mounting and have a WDE license plate. Applicable standards: DIN 43871, DIN EN 60670-24, WDE 0606-24
€278.21
ABB 2CPX031387R9999 UK636MW Media Distributor, Underput 3-row, Wifi Door
ABB 2CPX031387R9999 UK636MW Media Distributor, Underput 3-row, Wifi Door
2-7 days
The media distributors of the UK600 series are designed for under-put assembly. They convince with many new and unique technical features. Thus, an up to 200 % larger connection space allows easy and efficient installation of the devices. Through the generous space, all conceivable devices such as routers or other media modules find their safe place. Modular perforated plate mounting plates allow easy installation of the devices and an integrated rotatable 3-way socket ensures the power supply. With an optional removable frame, the UK600 is turned to eye-catching and integrated into any environment. The distributions can be used in undercut and hollow wall mounting and have a WDE license plate. Applicable standards: DIN 43871, DIN EN 60670-24, WDE 0606-24
€278.21
ABB 2CPX031386R99 UK660MV Media distributor, Underput 5-row, ventilated door
ABB 2CPX031386R99 UK660MV Media distributor, Underput 5-row, ventilated door
2-7 days
The media distributors of the UK600 series are designed for under-put assembly. They convince with many new and unique technical features. Thus, an up to 200 % larger connection space allows easy and efficient installation of the devices. Through the generous space, all conceivable devices such as routers or other media modules find their safe place. Modular perforated plate mounting plates allow easy installation of the devices and an integrated rotatable 3-way socket ensures the power supply. With an optional removable frame, the UK600 is turned to eye-catching and integrated into any environment. The distributions can be used in undercut and hollow wall mounting and have a WDE license plate. Applicable standards: DIN 43871, DIN EN 60670-24, WDE 0606-24
€278.21
ABB 2CMA100163R1000 B23 111-100 three-phase counter “steel”, 3 phases, direct connection 65A
ABB 2CMA100163R1000 B23 111-100 three-phase counter “steel”, 3 phases, direct connection 65A
2-7 days
The following values are output via a seven-segment display with up to 7 digits: active energy (class 1), power, currents, voltages (L-L; L-N) and frequency, both per phase and total. The communication can take place via the integrated infrared interface for connecting a KNX module. The energy meter has an output. This can optionally be used as a pulse output for outputting the active energy or as an alarm output. Up to 25 alarm values (swell values with time delay) can be set here. The counter is calibrated according to MID and approved according to IEC. The installation width is 4 DIN modules.
€278.21
ABB 2CDG110090R0011 BE/S4.20.2.1 binary input, 4x, contact query, REG
ABB 2CDG110090R0011 BE/S4.20.2.1 binary input, 4x, contact query, REG
2-7 days
The device queries 4 potential-free contacts with internally generated interrogation voltage. The input state is displayed via 4 yellow LED’s. Binary inputs enable a total of 4 input signals (in 2 groups). Each channel has a button for manual operation. The devices are used by ABB i-bus® supplies and does not require additional power supply.
€278.21
ABB 2CTB803973R0500 OVR T2 3N 40-275 P TS QS SPD Type 2 for 230/400V TT-3Ph. + TN-S
ABB 2CTB803973R0500 OVR T2 3N 40-275 P TS QS SPD Type 2 for 230/400V TT-3Ph. + TN-S
2-7 days
Overvoltage protection devices SPD type 2 with the QuickSafe® thermal monitoring are designed for protection in indirect lightning effects and in switching overvoltages. They are built as close as possible to the feed point of the electrical system. All OVR T2 consist of a base part and an interchangeable protection module. They are equipped with a mechanical function display and the TS variants have a potential-free alternating contact. They are compatible with the System per M compact series and can be saved with them via phase rails. Main application in sub-distributions and end circuits.
€274.72
ABB 1SVR730840R0500 CM-SRS.22S Power Monitoring Relay 2We,B-C=0,3-15A RMS, 24-240VAC/DC
ABB 1SVR730840R0500 CM-SRS.22S Power Monitoring Relay 2We,B-C=0,3-15A RMS, 24-240VAC/DC
2-7 days
The CM series current monitoring relays protect single-phase networks (DC or AC) from overflows between 3 ma and 15 A. The devices with the maximum measuring range of 1 A are available in two different connection versions. You have the choice between the proven screw connection technology (double chamber box connection terminals) and the toolless Easy Connect connection technology (push-in terminals). Devices with a measuring range of 15 A are available with screw connection technology.
€262.70
ABB 2CSF204325R1400 F204F-40/0,03 FI switch 4P, Type F, 40A, 30mA
ABB 2CSF204325R1400 F204F-40/0,03 FI switch 4P, Type F, 40A, 30mA
2-7 days
Fault current protection devices (Rccbs) offer personal and property protection as well as protection against electrically ignited fires according to DIN WDE 0100-410 and DIN WDE 0100-530. The F200 series fault current protection switches ensure protection against sinusoidal alternating currents and pulsating currents. As well as fault protection (protection in indirect contact), additional protection (with I?n = 30 ma) and fire protection (with I?n = 300 ma). They meet the product standards for Rcds type A IEC/EN 61008-1, 61008-2-1, 61543 (WDE 0664 10, 11, 30) and for type F DIN EN 62423 (WDE 0664-40). Areas of use are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Optimum compromise between safety and operational continuity thanks to the interference resistance against unwanted triggering and 10 ms short-term delay. The F200 F are mixed frequency sensitive for single-phase electronic consumers with frequency converters, with a frequency range of 0...1 khz for detecting the fault current and additionally detect pulsating fault currents with a DC component of up to 10 ma.
€258.34
ABB 2CSF204201R3400 F204AS-40/0,3 FI protection switch 4P,type A,40A,300mA,selective
ABB 2CSF204201R3400 F204AS-40/0,3 FI protection switch 4P,type A,40A,300mA,selective
2-7 days
Fault current protection devices (Rccbs) offer personal and property protection as well as protection against electrically ignited fires according to DIN WDE 0100-410 and DIN WDE 0100-530. The F200 series fault current circuit breakers ensure protection with sinusoidal alternating currents and pulsating currents with a smooth DC fault current proportion of up to 6 ma against ground. As well as fault protection (protection in indirect contact) and fire protection (with I?n = 300 ma). They meet product standards IEC/EN 61008-1, 61008-2-1, 61543 (WDE 0664 10, 11, 30) and F200 A to 100 A UL 1053. Areas of use are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous authorisations make the F200 fit for worldwide use. Optimum compromise between safety and operational continuity thanks to the interference resistance against unintentional triggering with impact current strength (shaft current form 8/20 μs) = 5000 A. selectivity with downstream devices with a smaller dimension fault current of, for example, 30 ma (see selectivities tables in the subchapter TECHNICAL details for fault current protection devices (RCDs)).
€228.53
ABB 2CSA255901R9164 AFDD+LS S-ARC1-C16, 6kA, 1P+N, 2TE fault arc protection device + LS
ABB 2CSA255901R9164 AFDD+LS S-ARC1-C16, 6kA, 1P+N, 2TE fault arc protection device + LS
2-7 days
Fault arc protection device (AFDD) with automatic fuse (MCB) according to IEC/EN 62606 (WDE 0665-10) and IEC/EN 60898-1 (WDE 0641-11) provide protection against serial and parallel fault arcs, protection against overcurrent (overload or short circuit), protection against overvoltage (only for AFDD internal) and protection against electrically ignited fires according to DIN20WDE 0. Mandatory areas of application according to DIN WDE 01000 are in single-phase AC voltage systems with In = 16 A in sleeping or staying areas of homes and day-to-day facilities for children, disabled or old people or barrier-free homes, as well as in rooms or places with fire risk (with special fire risk, fire-prone facilities), predominantly/mainly from combustible building materials (classification of combustability of building materials). It is recommended to use Afds in rooms with sleeping facilities, rooms or places with a fire-promoting structure and high connection power terminal circuits. In general, the AFDD is also recommended to increase fire protection against electrically ignited fires. LED indicator to identify the cause of triggering. Feeding from above or below as desired, transverse wiring, for example to FI protection switches in the rear terminal area, is possible. Accessory of the system per M compact®. IEC/EN 60898-1 Icn=6kA. AFDD+MCB S-ARC1 is 1polig protected (LS), switching 2polig.
€214.62
ABB 2CSA255901R9135 AFDD+LS S-ARC1-B13, 6kA, 1P+N, 2TE fault arc protection device + LS
ABB 2CSA255901R9135 AFDD+LS S-ARC1-B13, 6kA, 1P+N, 2TE fault arc protection device + LS
2-7 days
Fault arc protection device (AFDD) with automatic fuse (MCB) according to IEC/EN 62606 (WDE 0665-10) and IEC/EN 60898-1 (WDE 0641-11) provide protection against serial and parallel fault arcs, protection against overcurrent (overload or short circuit), protection against overvoltage (only for AFDD internal) and protection against electrically ignited fires according to DIN20WDE 0. Mandatory areas of application according to DIN WDE 01000 are in single-phase AC voltage systems with In = 16 A in sleeping or staying areas of homes and day-to-day facilities for children, disabled or old people or barrier-free homes, as well as in rooms or places with fire risk (with special fire risk, fire-prone facilities), predominantly/mainly from combustible building materials (classification of combustability of building materials). It is recommended to use Afds in rooms with sleeping facilities, rooms or places with a fire-promoting structure and high connection power terminal circuits. In general, the AFDD is also recommended to increase fire protection against electrically ignited fires. LED indicator to identify the cause of triggering. Feeding from above or below as desired, transverse wiring, for example to FI protection switches in the rear terminal area, is possible. Accessory of the system per M compact®. IEC/EN 60898-1 Icn=6kA. AFDD+MCB S-ARC1 is 1polig protected (LS), switching 2polig.
€210.64
ABB 2CMA100151R1000 B21 113-100 AC counter, M-bus “steel”, 1 phase, direct connection 65A
ABB 2CMA100151R1000 B21 113-100 AC counter, M-bus “steel”, 1 phase, direct connection 65A
2-7 days
AC meters for measuring single-phase networks via a direct connection for currents up to a maximum of 65 A. The following values are output via a seven-segment display with up to 7 digits: active energy (class 1), power, current, voltage (L-N) and frequency. The communication can take place via the integrated M-bus interface or via the infrared interface for connecting a KNX module. The energy meter has an output. This can optionally be used as a pulse output for outputting the active energy or as an alarm output. Up to 25 alarm values (swell values with time delay) can be set here. The counter is calibrated according to MID and approved according to IEC. The installation width is 2 DIN modules.
€206.67